![Cavagna group PRODIGI Installation, Operation And Maintenance Manual Download Page 25](http://html.mh-extra.com/html/cavagna-group/prodigi/prodigi_installation-operation-and-maintenance-manual_2574743025.webp)
INSTALLATION GUIDE
25
Rev. 0/ 14-07-2020
-
Close and screw the door back on.
Once the replacement has been completed, the icon will disappear on its own (subject to authorization for
replacement).
DISPOSAL
At the time of disposal, the batteries must be removed from the device, as indicated in ULxxxx. The device
is equipped with two non-rechargeable batteries, Lithium- Thionyl chloride technology (Li-SOCl2) described
below:
Secondary battery: The secondary battery Size C in Bobbin technology, nominal voltage 3.6 Vdc. nominal
capacity 8.5 Ah, is located in the compartment containing the electronic card, under it. This battery is not
removable because it is connected to the board and is protected by a meter seal.
Primary battery: The primary battery Size D, nominal voltage 3.6 Vdc. nominal capacity 19 Ah, is located in
the compartment on the left side of the meter. To remove, simply remove the three fixing screws, open the
battery cover and disconnect the battery connector from the board. The battery is marked with the symbol
for separate collection for batteries and accumulators, represented by a crossed-out wheeled bin.
Comentado [GA11]:
The correct UL standard reference
must be indicated