- 23 -
ENGLISH
8. General Display
Warning
1. Always turn off the mains supply, voltage 230 V/400 V, before installation, servicing/maintenance or
replacement.
2. Installation, repairs and maintenance should only be carried out by a qualifi ed fi tter.
Always take care when working with electricity !
Minimum requirements:
a. Ambient operating temperature: 0° ~ 40°C
b. Atmospheric humidity: 40 ~ 93%
c. Suppression:
IEC—801-norm
d. Voltage: AC 400V/230V (+10%, -15%) 50 Hz ± 1 Hz
e. Relay exit: 230V/2A
9. Operating the Display Panel
1. Function keys
1. ON
“
”: Press this key to start the machine.
2. SET: Press SET in the "ON" mode to activate the parameter setting
(original password is 00) see below.
3. Up
“
”: Press to select a wash cycle (90 seconds/120 seconds (standard) /180 seconds) The indication will
disappear 5 seconds after the cycle has been selected. Press this key in SET mode to increase the temperature.
The temperature will continue to rise for as long as the key is kept pressed in.
4. Down
“
”: Press this key in SET mode to reduce the temperature. The temperature will continue to fall as for
as long as the key is kept pressed in.
5. Stop
“
”: Press this key to stop the machine.
2. Display
There are 4 variable LCD displays on the operating panel. The 2 LCDs on the left indicate the rinse temperature,
and the 2 LCDs on the right indicate the wash temperature.