Performing Maintenance

Maintenance procedures are:

• Replacing the ultraviolet (UV) lamp. 

• Replacing the filters.

Replacing The UV Lamp

When the Yellow UV Lamp indicator lights, the ultraviolet lamp should be 

replaced within 30 days.

Here’s the step-by-step procedure. 

  1. Unplug the Purifier’s power cord from the electrical outlet. 

  2. Using index fingers, squeeze the locking tabs (figure 6) inwards towards 

    the center of the grill on top of the Purifier. Lift the grill up and remove. 

  3. Rotate the UV lamp one-quarter turn, Top-to-Back (figure 7), and remove 

    the lamp in similar manner of a florescent bulb with 2 pins per end.

  4. Insert the new UV Lamp in place and install by rotating one-quarter turn 

    (top-to-front). Handle the new lamp by the metal ends (figure 7a) 

    avoiding contact with the quartz tube. Finger prints and smudges can 

    be removed from the quartz sleeve with rubbing alcohol.

  5. Replace grill removed in previous step 2. by pressing it into position 

    until it locks. The aluminum reflector must be positioned over the lamp, 

    nearest the front of the unit. (figure 7a).

  6. Reset the UV LAMP timer by placing the end of a paper clip or toothpick

    into the rest hole and Gently press in the switch to return the indicator 

    light to Green OK. The UV Lamp will again be counted to zero over 12 

  month 

period.

 

 

 

 

 

 

 

This completes lamp replacement procedures.

Set Purifier For Room Size

 

1. Measure the room the Purifier is to serve, multiplying length by width 

 

  to obtain a measurement in square feet (or square meters.)

 

2. Review the charts below to find the room and identify the respiratory 

 

  condition the unit is to serve.

 

3. Use the “Heavy Duty” chart if you seriously suffer allergic reactions  

 

  from particulate matter (pollen, dust, dust mites, animal dander, etc.) 

 

  or airborne chemicals (pesticides, herbicides, cleaning solutions, etc.). 

 

  Use the “Light Duty” chart if the area you live in is unhealthy from time 

 

  to time, or you suffer mild allergies occasionally.

Select Operating Mode

To make your MODE selection, press the black SELECT button (figure 3) re-

peatedly until the appropriate light is “On” next to the desired operating mode.

AUTO MODE - This is the mode, most commonly used. In this mode the elec-

tronic sensors combines the real time chemical sensor with the blower speed. 

If the chemical sensor detects an 

unhealthful amount of chemicals 

present in the air (indicated by the 

red light on the quality scale) the 

electronic controls will automati-

cally speed the blower up to the 

next setting.

SUPER MODE - This mode may 

be selected during periods of high

Figure 6

Figure 7

Figure 7a

Heavy Duty

People with Severe Respiratory Problems

SUPER MODE  SQ. FT.  SQ. Meters

Extra Large 

  660 

  61

AUTO MODE 

SQ.FT. 

SQ. Meters

Extra Large 

  565 

  53

Large 

  485 

  45

Medium 

  400 

  37

Small 

  350 

  33

X Small 

  300 

  28

Light Duty

Average Home

SUPER MODE  SQ. FT.  SQ. Meters

Extra Large 

  1980 

  183

AUTO MODE 

SQ.FT. 

SQ. Meters

Extra Large 

  1695 

  159

Large 

  1455 

  135

Medium 

  1200 

  111

Small 

  1050 

   99

X Small 

   900 

   84

Figure 3

SUPER
ECONOMY
SLEEP

AUTO

SELECT

MODE

Figure 2

X-LARGE 
LARGE
MEDIUM 
SMALL
X-SMALL

ROOM SIZE

SELECT

-page 4-

-page 7-

Backside