background image

Page A2

 

 

 

You’ve Made the Right 
Choice

 

Using your 

Euro

-MERiDIAN Alarm 

System just couldn’t be easier! 

 
 

This is the Keypad from where 
you control your Alarm System. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Note: 

For your security, the keypad becomes 

disabled for 90 seconds after 24 incorrect key-
presses, or after 6 attempts to present invalid 
tags. It will subsequently be disabled again 
after 7 further incorrect key-presses or after 
another invalid tag is presented. Once a 
correct code or tag has been registered, the 
keypad is returned to normal operation.  

Summary of Contents for Euro-MERiDIAN

Page 1: ...ry Log F11 12 SMS Phonebook F13 Walk Testing Detectors F14 Testing your Sounder F15 SMS Messaging System F16 17 Dial Out Menu F18 Allow Engineer Menu F19 Block Remote Set F20 Perform Anti Code Reset F...

Page 2: ...stem Note For your security the keypad becomes disabled for 90 seconds after 24 incorrect key presses or after 6 attempts to present invalid tags It will subsequently be disabled again after 7 further...

Page 3: ...your alarm installation engineer The 10 digit numeric keypad is where you use your PIN code The A B C D keys help simplify use and will illuminate to highlight your choice of security cover or flash i...

Page 4: ...following lamps will light Alarm tamper or fault The relevant detail of the problem will be shown on the display To clear the display press the Yes key the display will clear automatically after 3 min...

Page 5: ...ty Proximity Tag or Card will set or unset your Alarm system with the minimum of fuss or complexity The Tag contains NO batteries and is completely maintenance free Just touch the Tag to the logo to u...

Page 6: ...Using the Keypad with your PIN Code or...

Page 7: ...Checks Before you set your system You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors Close Windows Close Doors Excl...

Page 8: ...which areas you set see page D2 Leave by agreed Exit Route Close and Lock the Final Exit Door Finally press the Push to Set button if fitted that is mounted externally by the final exit door Exit tone...

Page 9: ...display will show the nature of the problem An appropriate A B C D key will flash to indicate within which area the fault exists The tone will cease after about 10 seconds Press the NO key The system...

Page 10: ...d the exit tone continues to sound an interrupted tone beep beep beep You have probably left a protected door on the exit route open Return to the keypad and note the message on the display Stop the s...

Page 11: ...agreed entry route and go straight to the keypad Entry tone will be sounding beep beep beep Key in your PIN code or present your Tag Entry tone will cease To indicate that the system has unset the un...

Page 12: ...rm at night the Euro MERiDIAN s intelligent operating system will realise which level of security you require and will set only part of the system You will NOT need to press a Push to Set button if yo...

Page 13: ...go to the keypad and enter your PIN code or present your Tag The appropriate A B C D keys will illuminate Exit tone will start Leave the protected area and retire to the un protected area eg upstairs...

Page 14: ...When Problems Arise Just Key in your PIN Code or...

Page 15: ...g The Alarm will stop sounding The display will indicate the problem Press the YES Key Euro MERiDIAN will advise you on any action that is needed If the Alert LED indication remains lit there is addit...

Page 16: ...for further use But if you have caused the alarm in error your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present You will be required...

Page 17: ...ed alarms in the same area or 1 confirmed alarm Keypad After 23 keypresses without entering a valid code keys are disabled for 90 seconds After reinstatement this will be repeated after each 7 keypres...

Page 18: ...Setting Individual Areas...

Page 19: ...o give names to all four of the A B C D areas so that you can easily identify them For example A Reception or All Set B Warehouse Bedtime Set C Office Cat in Lounge D Storeroom Dog in Study In additio...

Page 20: ...wish to set all the areas assigned to your code Tag simply select the areas you wish to Set by pressing the relevant A B C D key s To change your mind press the relevant A B C D key s again Press the...

Page 21: ...ag is presented only area A will be unset If an A B tag is presented both A B will be unset An A B C tag will unset A B leaving C unset If entry timer is not running You will be asked if you wish to s...

Page 22: ...t areas you would like to set or unset regardless of whether the entry timer is running or not providing you have a code valid for the relevant areas This function can only be enabled by your alarm in...

Page 23: ...Page D3 Flexi Set This Page has been left Blank for Notes...

Page 24: ...More Advanced Functions...

Page 25: ...or during the day Simply press the C key The display will show a C Now if the door opens you will be alerted by the chime tone To cancel the Chime function simply press C again Note This is only opera...

Page 26: ...display will ask if you wish to set with the fault To omit the fault Press YES or NO if you don t The system will then set as normal The fault will be omitted for this one arming period only NOTE iiii...

Page 27: ...YES key When the OMIT ZONE menu is displayed Key in the number of the zone you wish to omit and press YES Always use a leading zero eg 02 is zone 2 On larger systems 002 is zone 2 If it has been accep...

Page 28: ...reset Enter you PIN code or present your Tag Note ghgfiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii This facility is only available if it has been enabled by your alarm installer 2 Key PA and any duress codes progr...

Page 29: ...This Page has been left Blank for Notes...

Page 30: ...enter Manager Menu press D and then key in your code or present your tag The screen will display any relevant information simply press No to move into Manager Menu We recommend that your system is be...

Page 31: ...t Test CHC Communications Dial Out Menu Allow Engineer Menu Block Remote Set Download only in Engineer Enter Anti Code Exit Manager Menu These features can also be accessed with a standard user code P...

Page 32: ...user code The first Menu choice asks you if you wish to Set Date Time If you wish to enter the menu press YES But if you wish to move on to other Manager Menu items press NO The USER MENU is similar...

Page 33: ...ter Year eg 01 2001 Press YES Enter Month Press YES Enter Day Press YES Enter Hours 24 hour clock Press YES Enter Minutes Press YES To go to the next menu press NO again Press YES Press NO to move to...

Page 34: ...d day alarm type can be omitted this way as set up by your alarm installing company Enter the zone number you wish to omit Press YES To reinstate zones simply key in the number again Press No when you...

Page 35: ...ress NO to programme the Master Manager Code Turn to the next page to continue to programme user codes Press YES Press NO to move to the next menu The Master Manager Code can only be changed by the Ma...

Page 36: ...n the new 4 5 or 6 digit PIN code you require or present the new Tag To delete a code or Tag press C Press YES Euro MERiDIAN will not allow you to programme in codes that are already in use by the sys...

Page 37: ...A B C D keys choose the areas you wish to be controlled by the code holder Managers may not give other users access to areas he himself cannot access Press YES Choose the limits you wish to place on t...

Page 38: ...ly set the areas assigned without offering you the opportunity to choose For simplicity of use choose NO Make your choice with the B and D keys Press YES Flexi Set Yes 1 Flexi Set No 0 SET SYSTEM Syst...

Page 39: ...ove to next menu To assign a Tag to Access Control Readers or a Ward Reader Enter the Reader Numbers required Press YES To cancel a reader from the list Key in the number again Press YES When you have...

Page 40: ...e used as follows A capital letters B moves cursor left C Clears Character creates a space D Cursor moves right eg to write Ben simply press the 2 key twice A key for capital D move cursor right 3 key...

Page 41: ...e next menu Press YES To advance through the logs Press D For added information Press C To move backward to previous events Press B To stop review Press NO To move to the next menu press NO again REVI...

Page 42: ...ory Log If Access Control Facility is in use a separate log is available dedicated to events using this function Follow the same procedure as described on page F11 but press NO to choose between PANEL...

Page 43: ...YES Using the numeric keys type in the new telephone number do not leave any spaces You can move the cursor back with the B key and forward with the D key Use the C key to delete a character Press YES...

Page 44: ...rs waiting to be tested will scroll in the display Walk around the building and trigger all of the detectors The system will chime each time a detector responds When all detectors have been activated...

Page 45: ...Page F15 Testing your Alarm Sounders Press YES Press NO to move to the next menu Press YES Siren will sound Strobe will flash Press NO to move to next menu SIREN TEST Testing Siren SIREN TEST...

Page 46: ...tomatically via a premium rate number when the Euro MERiDIAN makes its regular authorisation and routing call to the messaging computer Should this call fail the display will show CHC Test Fail until...

Page 47: ...is test is only undertaken under the supervision of your alarm installation engineer Press NO to move to the next menu Press YES to make the test under the direction of an alarm engineer the test call...

Page 48: ...e required PC from the list 1 4 and Press Yes Use the D key to select the operation you require Upload Logs View the system history on your PC where it can be searched and printed Diagnostics Sends el...

Page 49: ...aintenance visit or correct a fault after an alarm he will require access to the programming of the system Press YES Use B D keys to make your choice Press YES After the engineer has finished on site...

Page 50: ...so that your alarm installation company or company manager can set or unset the system remotely via PC Should you wish to block this access you can do so through this menu Press YES Make your choice...

Page 51: ...enu Your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present Press YES You will be required to quote this 5 digit code by telephone advi...

Page 52: ...Mobile Telephone Numbers page F13 Allow Engineer Access page F19 Inhibit omit Zones from the system page F3 Allow Remote Set page F20 To do so press D and enter your Manager PIN code or Tag Every use...

Page 53: ...23 Menu Exit To exit from Manager Menu and return to normal mode Press YES If you wish to select any of the Manager Menu items again press the NO key until your choice is displayed see F2 EXIT MANAGER...

Page 54: ...table for use in installations designed to meet the requirements of Grade 2 Euro G3 panels meet the requirements of Grade 3 External set unset readers and access control readers meet the requirements...

Page 55: ...ing This information should be removed from the manual and stored in a secure location Photocopy this page if you have more users No Name Type Areas Attributes FlexiSet Access Reader 00 John Manager A...

Page 56: ...e companies whose operation is outside of the control or influence of Castle Care Tech Ltd Castle Control Panels have an embedded premium rate telephone number that is used to contact a Castle host co...

Reviews: