Station update
For the update, you will be provided with a file containing the new software version, if necessary.
You must then download this file via the Web Page. The entry station will restart so as to apply the update. The
update does not modify the user parameters in any way.
Backup on power outage
When a power outage occurs, the station can back up the following information:
counter values
history
backed up events (these events are defined from CastelServer)
interface statuses
History function
The history displays station events. They are listed by showing the date and time of the relevant event, a description
and additional information.
Functions used to meet the accessibility law (depending on versions)
Rule: ‘Any signal related to the operation of an access device is audible and visual. ’
During the call, the entry station sends a configurable voice message and the call signal LED or a call visual on the
display switches on.
When the call is going through, the entry station sends a configurable voice message and the call signal LED or a call
visual on the entry station display switches on.
During the internal relay command at the station, the entry station sends a configurable voice message and the door
signal LED or a door visual on the display switches on.
Rule: ‘When there is an electric unlocking device, it enables any person with reduced mobility to reach the
door and start the opening manoeuvre before the door becomes locked again. ’
The entry station’s strike plate relay can be configured with a configurable hold time.
Rule: ‘In the absence of a direct view of these accesses by staff, the intercom devices feature a system
enabling staff to view the visitor.
’
The entry stations have a wide angle colour camera.
Rule: ‘When they are installed or renewed, the intercom devices have a magnetic induction loop. ’