AUDIO VIDEO IP SCROLLING AND/OR KEYPAD DOOR ENTRY STATION
Technical data sheet no. 604-0094C
www.castel.fr
Page 13 / 22
EN
FR
CONNECTION
Power supply connection (24VDC)
The required power supply is 20Vdc at 30Vdc..
Note: The door entry station can be powered by PoE + or PoE
Ethernet (with some restrictions)
Your device is delivered from the factory in POE / POE +
configuration, however in some cases it may be necessary to
block it in a POE configuration alone (distribution of the power
of the Switch on several gatekeepers / poor power management
of the Switch /. ..).
In this case with the device not powered and with a small non-
conductive clamp, remove the strap indicated in red on the
photo below
IP network connection (ETH0 / ETH1)
The connection is made via a 10/100/1000 Mbits Ethernet RJ45
link.
2 Available Ethernet port (1 PoE or PoE + and 1 non PoE
compatible)
Connection of 0dB output (0dB +/-)
Applicable from software
version
1.5.0
A 0dB differential output allows the connection of an external
amplifier.
+: hot spot
-: cold point
0V: GND
Magnetic Loop Loop Output Connection (Loop)
A Loop output allows the connection of the magnetic induction
loop.
Connection to the VDIP RS485 bus
Configurable with CASTELSuite
The device is connected to the VDIP RS485 devices (VD4S réf 110.1000, VD8EI réf 110.1100, VDLECT réf
110.1200) via a RS485 bus line (bus wiring: several devices can be installed on one bus line).
The bus connection between the peripherals and the module is made by points RS1 and RS2 (via a twisted pair) and
the ground. Establish the point-to-point connection by following the order of the signals.
The maximum length of the bus is 1 km. A 120 ohm resistor needs to be fitted (provided with the RS485 device)
between points RS1 and RS2 at each end of the bus.
Input connection (IN1 / IN2 / 0V)
Two digital inputs allow the connection of a dry contact (do not apply voltage). To be activated, the input must be
grounded.
The contact can be deported up to 1Km.
Connection of relay outputs (RL1 / RL2)
The connection is made via a 3-point terminal block providing the "Common (C) / Rest (NC) / Work (NO)" interface.
If you use one of these relay outputs to control an AC or DC strike, wire a non-polarized 58V diode in parallel to the
dry contact between C and NO or C and NC depending on use (diode supplied).
Protection against electrostatic discharges
Connect the device to the ground using the terminal provided (Mounted on the fixing of the microphone).