AXESS AUDIO VIDEO IP INTERCOM FROM 1 TO 4 PB
Technical data sheet no. 600-0206B
www.castel.fr
Page 8 / 12
FR
EN
FUNCTIONS
The station is designed to communicate with all the devices from the Castel IP intercom range (XELLIP, CAP IP…),
softphones, SIP phones or any other equipment compatible with the SIP standard.
The station can also establish an audio communication with the devices from the Castel digital and analog intercom
range. This type of communication requires the use of an additional M-HYB-IP gateway.
General functions of the entry station
•
Configuring a network connection.
•
Configuring one or many SIP account
•
Setting the date and time manually or via an NTP server. The station can also be used as a NTP server.
•
Management of audio and video communications (according to version)
↘
Possibility to set the priority level of the device
↘
Possibility to set the call and communication timeout
↘
With or without automatic answering, with or without a delay
↘
Possibility to enable the privacy mode for automatic answering
Audio interface functions
•
Configuring the volume of the loudspeaker and microphone
•
Configuring the Anti Echo Acoustic (AEC)
•
Configuring the RTP port number
•
Enabling/Disabling audio codecs
•
Configuring ring tones and tones
•
Configuring DTMF commands used to control the local relay, for example
•
Configuring noise detection used to activate a call, for example
•
Switching to simplex through a DTMF command from the calling party station
↘
“*” switches to listening simplex
↘
“#” switches to speech simplex
↘
“0” is used to return to standard operation
Video interface functions
•
Choice of resolution: QCIF / QVGA / CIF / VGA / HD / Full HD
•
Activating bandwidth management
•
Configuring the RTP port number
•
Enabling/Disabling video codecs
Programmable button functions
Each button can be programmed and is used to:
•
Call 1 to 10 stations simultaneously or with timeout
•
Control the local relay, the station relay in communication or send a DTMF code
•
End a call
•
Perform a list of advanced actions
Digital input interface functions
•
Configuring the type of input: STATUS or COUNTER
•
Configuring the input active state: open or closed contact
•
Configuring a delay for taking into account a change of state (anti-rebound function)
•
Configuring the counter threshold
•
Inhibit the input
Output interface functions
•
Configuring the type of output relay: monostable, bistable or flashing
•
Configuring the type of contact: Normally Open/Normally Closed
•
On/Off output control
•
Open/Closed override output control
•
Configuring output time parameters