INSTALLATION: 
•  for outdoor locations it is mandatory to use (CEI EN 60598-1; 

CEI 20-40/CENELEC HD516S1) a three core flexible neoprene rubber cable 
type H07RN-F with diameter between 7 and 10mm. PVC insulated cables or 
with outer PVC cover or any cable different from the one here prescribed are 
not allowed.  

N.B.: Suitable cable is supplied on request.

• to open the appliance, unscrew the two screws of the body (pict. 1).

• use the base to mark the points for fixing to the wall. 

• fix the base to the wall. 

ATTENTION: Way of assembly BASE-FIXTURE obligatory 

• connect the neutral phase cables to the terminal, respecting the polarities and 

the ground cable to the appropriate plate (pict. 2).  

• to guarantee a perfect seal, after having fixed the appliance, insert the rubber 

caps of the seal as shown in picture 3.

• Insert the cable-clamp (pict. 4)

 

connect the body of the appliance to the 

base on the wall and tighten the two 
screws. Make sure that the washer 
is in a good condition and that the 
rabbet surface is clean.

• orient the lamp in the chosen 
direction using the two graduated 
scales as an aid and screw the screw 
for the version Q2 (pict. 5A) 
or the two screws for the version 
T2 (pict. 5B) Slightly tighten the two 
dowels  to avoid the lamp rotating 
accidentally (pict. 6). 

RE-LAMPING (T2-Q2/MH)

to access the bulb, you have to 
unscrew the screws in the rear part of 
the head of the appliance (pict. 7).

LED RELAMPING - MAINTENANCE
N.B.: The electrical circuit complete 
with leds has to be required to our 
company or its distributors. 
The replacement must be done 
by a qualified electrician.

ACCESSORIES
It is possible to provide the fixture 
with accessories that allow to obtain 
light blades, coloured beams and 
other effects, as shown in the product 
catalogue.

Features - meaning of the symbols shown on the label:
suitable for exterior or interior free air operation
wall-,  ceiling- and pole mounting

 

IP65  totally dust-proof - jet-proof from any direction 

 

  installation on normally inflammable surfaces allowed

 

 

minimal distance between fitting and lighted object

        Classe I 

  simple insulation: earth required

 

  replace the damaged protective glass screen

 

  getting rid of as urban waste forbidden 

 

  separate collection is mandatory when 

 

  the product is at the end of its life

Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as 
the serial number that recognizes the fixture.

Relamping - Maintenance: 
•  respect fully type and power of lamp as shown on the label. Read carefully the instructions of the lamp manufacturer for proper lamp use. The relamping must be done 

with maximum attention avoiding to dirt the sealing gasket and its contact surface. It is therefore necessary, before opening the fixture, to clean it accurately. If the gasket 
is damaged, deformed or not in perfect condition it is necessary to change it. 

•                 it is essential to do a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of mud and dirtiness resulting in dangerous overheating due to 

incorrect light and heath dissipation. Clean carefully the glass screen removing limescale by means of a scraper.

pict. 1

pict. 2

pict. 4

pict. 3

• max wind exposed surface: 
 

D55/T2

  

0,06m

2

 

D55/Q2

  

0,08m

2

• weight: 

  

D55/T2 

 

3,5Kg

 D55/Q2

 

5,0Kg

• mounting height: any

pict. 6B-T2

pict. 8

pict. 7

pict. 5B-T2

pict. 6A-Q2

pict. 5A-Q2

D55/T2

D55/Q2

Ø min 8,5 mm
Ø max 12 mm

Ø min 7,5 mm
Ø max 8,5 mm

DISTANCE BETWEEN HOLES

line 

entry

BASE

60 

50 

165 

70 

Ø1

8

9

 

85 

165 

276 

183 

21

7

 

28

6

 

284 

353 

85 

165 

205 

217 

207 

2

88

 

87 

  product in compliance with the requirements
  of the European Community Directories

P

NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or 
transformed and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of 
guarantee. The company cannot be held responsible for damage caused by incorrect assembly.

Summary of Contents for D55/T2

Page 1: ...nfiammabili distanza minima tra apparecchio e soggetto illuminato Classe I isolamento semplice richiesta la messa a terra di protezione sostituire i vetri di protezione se danneggiati vietato lo smalt...

Page 2: ...from any direction installation on normally inflammable surfaces allowed minimal distance between fitting and lighted object Classe I simple insulation earth required replace the damaged protective gl...

Page 3: ...des surfaces normalement inflammables distance minimum entre l appareil et la partie clairer Classe I isolation simple mise la terre n cessaire remplacer les verres de protection abim s il est interd...

Page 4: ...serstrahlen aus allen Richtungen Geeignet f r Montage auf normal entflammbaren Befestigungsfl chen Minimalabstand zwischen Leuchtk rper und beleuchtetem Gegenstand Klasse I mit Schutzleiteranschluss d...

Page 5: ...o le istruzioni ad esso allegate Montaggio a PALO con GANASCIA D55 2 GA posizionare la ganascia sul palo nel punto desiderato fig 7 eseguire sul palo due fori di fissaggio e un foro 20 per il passaggi...

Page 6: ...e the fixing to orientate the beam pict 3 close the fixture RASTER R WARNING the accessory D55 T2 R raster can only be installed on versions with an narrow beam optic NB make sure that the fixture is...

Page 7: ...fixation pour orienter le faisceau fig 3 richiudere l apparecchio RASTER R ATTENTION l accessoire D55 T2 R raster peut etre install seulement sur versions avec une optique faisceaux troits NB assurez...

Page 8: ...MAST mit KLEMMBACKE D55 2 GA die Klemmbacke am Mast an der gew nschten Stelle positionieren Abb 7 Run auf den Pol zwei L cher und ein 20mm Loch f r Kabeldurchf hrung die Leuchte an der Mast mit den g...

Reviews: