installation and maintenance sheet
D55 flex/T2-Q2-MH-LW
INSTALLATION:
• for outdoor locations it is mandatory to use (CEI EN 60598-1;
CEI 20-40/CENELEC HD516S1) a three core flexible neoprene rubber cable
type H07RN-F with diameter between 7 and 10mm. PVC insulated cables or
with outer PVC cover or any cable different from the one here prescribed are
not allowed.
N.B.: Suitable cable is supplied on request.
• to open the appliance, unscrew the two screws of the body (pict. 1).
• use the base to mark the points for fixing to the wall.
• fix the base to the wall.
ATTENTION: Way of assembly BASE-FIXTURE obligatory
• connect the neutral phase cables to the terminal, respecting the polarities and
the ground cable to the appropriate plate (pict. 2).
• to guarantee a perfect seal, after having fixed the appliance, insert the rubber
caps of the seal as shown in picture 3.
• Insert the cable-clamp (pict. 4)
connect the body of the appliance to the
base on the wall and tighten the two
screws. Make sure that the washer
is in a good condition and that the
rabbet surface is clean.
• orient the lamp in the chosen
direction using the two graduated
scales as an aid and screw the screw
for the version Q2 (pict. 5A)
or the two screws for the version
T2 (pict. 5B) Slightly tighten the two
dowels to avoid the lamp rotating
accidentally (pict. 6).
RE-LAMPING (T2-Q2/MH)
to access the bulb, you have to
unscrew the screws in the rear part of
the head of the appliance (pict. 7).
LED RELAMPING - MAINTENANCE
N.B.: The electrical circuit complete
with leds has to be required to our
company or its distributors.
The replacement must be done
by a qualified electrician.
ACCESSORIES
It is possible to provide the fixture
with accessories that allow to obtain
light blades, coloured beams and
other effects, as shown in the product
catalogue.
Features - meaning of the symbols shown on the label:
suitable for exterior or interior free air operation
wall-, ceiling- and pole mounting
IP65 totally dust-proof - jet-proof from any direction
installation on normally inflammable surfaces allowed
minimal distance between fitting and lighted object
Classe I
simple insulation: earth required
replace the damaged protective glass screen
getting rid of as urban waste forbidden
separate collection is mandatory when
the product is at the end of its life
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as
the serial number that recognizes the fixture.
Relamping - Maintenance:
• respect fully type and power of lamp as shown on the label. Read carefully the instructions of the lamp manufacturer for proper lamp use. The relamping must be done
with maximum attention avoiding to dirt the sealing gasket and its contact surface. It is therefore necessary, before opening the fixture, to clean it accurately. If the gasket
is damaged, deformed or not in perfect condition it is necessary to change it.
• it is essential to do a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of mud and dirtiness resulting in dangerous overheating due to
incorrect light and heath dissipation. Clean carefully the glass screen removing limescale by means of a scraper.
pict. 1
pict. 2
pict. 4
pict. 3
• max wind exposed surface:
D55/T2
0,06m
2
D55/Q2
0,08m
2
• weight:
D55/T2
3,5Kg
D55/Q2
5,0Kg
• mounting height: any
pict. 6B-T2
pict. 8
pict. 7
pict. 5B-T2
pict. 6A-Q2
pict. 5A-Q2
D55/T2
D55/Q2
Ø min 8,5 mm
Ø max 12 mm
Ø min 7,5 mm
Ø max 8,5 mm
DISTANCE BETWEEN HOLES
line
entry
BASE
60
50
165
70
Ø1
8
9
85
165
276
183
21
7
28
6
284
353
85
165
205
217
207
2
88
87
product in compliance with the requirements
of the European Community Directories
P
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or
transformed and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of
guarantee. The company cannot be held responsible for damage caused by incorrect assembly.