Cast Tec Arbeia Juno Installation And Operating Instructions Manual Download Page 8

 

7

 

Juno & Vulcan 

Issue 01 06/13

 

If the stove is to be used with smokeless fuel exclusively then the solid fuel fitting kit 
(supplied separately) must be fitted to the stove according to the instructions supplied 
with it. 
 
Upon completion of the installation, allow a suitable period of time for any fire cement 
and mortar to dry out. A small fire may then be lit and checked to ensure the smoke and 
fumes are taken from the stove up the chimney and emitted safely to atmosphere.  
 
Advise the customer not to run the stove at full output for at 3 

– 4 days. Explain that the 

stoves can provide much more or less than their rated heat outputs depending upon 
how they are burnt and fuels and fuel loads used.

  

 
Warn the customer that using excessive air (having the air controls open too wide 
for too long) can over-fire and irreparably damage the stove. Damage caused by 
over firing is NOT covered by any warranty. 

 
On completion of the installation and commissioning, check all parts of the appliance are 
correctly fitted and ensure that the operating instructions and operating tools (including 
gloves) for the stove are left with the customer. You must be sure to advise the 
customer on the correct use of the appliance with the fuels likely to be used on the stove 
and warn them to use only the recommended fuels for the stove. 
 
Advise the user on what to do should smoke or fumes be emitted into the room from the 
stove 

– see 

Safety Notes

 section. The user should be warned that they MUST use a 

suitable fireguard in the presence of children, aged and/or infirm persons.  
 

5.0  Technical Data  

 
 
 

 Model  

Juno 

5kW 

Vulcan 

8kW 

 

 

Appliance gross weight 

(packed) (Kg): 

74 

81 

 

 

Efficiency on wood fuel: (%)   

79.0 

78.6 

 

 

Declared nominal output: 

(kW)  

5.0 

7.6 

 

 

Tested wood re-fuelling 

interval: (h) 

0.75 

 

 

Flue gas mass flow on wood 

fuel: (g/s) 

5.1 

5.8 

 

 

*Flue Temp on wood fuel: 

(Deg C) 

229 

302 

*at nominal heat output

 

 

Max Log Length:  

375mm 

14.5” 

 375mm 

14.5” 

 

 
 

Efficiency on Ancit fuel: (%)   

75.4* 

77.2* 

*With DEFRA air limiter fitted 

– approx. 81% without. 

 

Declared nominal output on 

Ancit Fuel: (kW)  

5.0 

8.0 

 

 

Tested Ancit re-fuelling 

interval: (h) 

 

 

Flue gas mass flow on Ancit 

fuel: (g/s) 

4.5 

5.9 

 

 

*Flue Temp on Ancit fuel: 

(Deg C) 

276 

329 

*at nominal heat output

 

 

Summary of Contents for Arbeia Juno

Page 1: ...times Instructions for wood burning MUST be followed in order to ensure compliance at all times Arbeia Juno Arbeia Vulcan FREESTANDING STOVE RANGE 5 8 kW Nominal Outputs Installation and Operating Ins...

Page 2: ...ortant safety information 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 6 4 6 Hearths 6 4 7 Commissioning Handov...

Page 3: ...MAY BE PACKED ON TOP OF THE BAFFLE PLATE REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT See List of Components section and check contents carefully 2 1 To remove the baffle plate first remove the tw...

Page 4: ...documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful In addition to these instructions the requirements of BS 8303 and BS EN 15287 must...

Page 5: ...skin In case of skin contact wash immediately with plenty of water 3 1 10 Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation th...

Page 6: ...the rate of burning can be controlled to prevent over firing 4 4 Connection to the Chimney This appliance is not suitable for use in a shared flue When using a liner a 5 flexible flue liner is permitt...

Page 7: ...m must be left around the sides and top and at least 50mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance A clearance of 150mm will gi...

Page 8: ...re correctly fitted and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use...

Page 9: ...d from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt applia...

Page 10: ...ted part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that assist...

Page 11: ...ll then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes or...

Page 12: ...indling sticks and or firelighters If using Ancit place a layer of ancit into the firebox as well Light the fire at the base leaving the secondary air control fully open Leave the door slightly ajar f...

Page 13: ...open first and then open the secondary air controls Warning The stove will remain very hot for a considerable time after the fire has died down or been extinguished Notes Warning Petroleum coke fuels...

Page 14: ...pose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek profes...

Page 15: ...14 Juno Vulcan Issue 01 06 13 8 1 Arbeia Juno Stove Dimensions 8 2 Arbeia Vulcan Stove Dimensions...

Page 16: ...d to product failure 6 Where can I get spare parts Your local Cast Tec stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Cast...

Reviews: