Cast Tec Arbeia Juno Installation And Operating Instructions Manual Download Page 2

 

1

 

Juno & Vulcan 

Issue 01 06/13

 

PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY!

 

For safety reasons it is essential that your stove is correctly installed and 
operated. Cast Tec Stoves cannot accept responsibility for any fault or 
consequential problems arising through incorrect installation or operation. 

 

TABLE OF CONTENTS 

 

Section   

 

 

 

 

 

 

 

 

Page No 

 
1. List of Components 

 

 

 

 

 

 

 

 
2. Component Identification and Assembly 

 

 

 

 
3. Installation Instructions 

 

 

 

 

 

 

3.1 Warnings and important safety information   

 

 

 

 
4 Installation Information  

 

 

 

 

 

 

4.1 Chimney   

 

 

 

 

 

 

 

 

4.2 Ventilation 

 

 

 

 

 

 

 

 

4.3 Flue Draught 

 

 

 

 

 

 

 

 

4.4 Connection to Chimney 

 

 

 

 

 

 

4.5 Material Clearances 

 

 

 

 

 

 

 

4.6 Hearths   

 

 

 

 

 

 

 

 

4.7 Commissioning & Handover   

 

 

 

 

 

 

5. Technical Data 

 

 

 

 

 

 

 

 

 
6. Operating Instructions  

 

 

 

 

 

 

6.1 DEFRA Clean Air Act   

 

 

 

 

 

 

6.2 Air controls 

 

 

 

 

 

 

 

 

6.3 Cleaning   

 

 

 

 

 

 

 

 

6.4 Fuels 

 

 

 

 

 

 

 

 

 

10 

6.5 Important Notes for Wood Burning   

 

 

 

 

10 

6.6 Notes on Smokeless fuel (Ancit) burning 

 

 

 

 

11 

6.7 Lighting the stove 

 

 

 

 

 

 

 

11 

6.8 Re-fuelling 

 

 

 

 

 

 

 

 

11 

6.9 Shutting down   

 

 

 

 

 

 

 

12 

6.10Shutting down for prolonged periods 

 

 

 

 

12 

6.11 Maintenance   

 

 

 

 

 

 

 

12 

7. Safety Notes for your Guidance   

 

 

 

 

12 

 
8. Dimensions   

 

 

 

 

 

 

 

 

14 

 

8.1 Juno 

 

 

 

 

 

 

 

 

 

14 

 

8.2 Vulcan 

 

 

 

 

 

 

 

 

 

14 

 

 

9. Frequently Asked Questions 

 

 

 

 

 

15 

Summary of Contents for Arbeia Juno

Page 1: ...times Instructions for wood burning MUST be followed in order to ensure compliance at all times Arbeia Juno Arbeia Vulcan FREESTANDING STOVE RANGE 5 8 kW Nominal Outputs Installation and Operating Ins...

Page 2: ...ortant safety information 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 6 4 6 Hearths 6 4 7 Commissioning Handov...

Page 3: ...MAY BE PACKED ON TOP OF THE BAFFLE PLATE REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT See List of Components section and check contents carefully 2 1 To remove the baffle plate first remove the tw...

Page 4: ...documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful In addition to these instructions the requirements of BS 8303 and BS EN 15287 must...

Page 5: ...skin In case of skin contact wash immediately with plenty of water 3 1 10 Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation th...

Page 6: ...the rate of burning can be controlled to prevent over firing 4 4 Connection to the Chimney This appliance is not suitable for use in a shared flue When using a liner a 5 flexible flue liner is permitt...

Page 7: ...m must be left around the sides and top and at least 50mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance A clearance of 150mm will gi...

Page 8: ...re correctly fitted and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use...

Page 9: ...d from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt applia...

Page 10: ...ted part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that assist...

Page 11: ...ll then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes or...

Page 12: ...indling sticks and or firelighters If using Ancit place a layer of ancit into the firebox as well Light the fire at the base leaving the secondary air control fully open Leave the door slightly ajar f...

Page 13: ...open first and then open the secondary air controls Warning The stove will remain very hot for a considerable time after the fire has died down or been extinguished Notes Warning Petroleum coke fuels...

Page 14: ...pose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek profes...

Page 15: ...14 Juno Vulcan Issue 01 06 13 8 1 Arbeia Juno Stove Dimensions 8 2 Arbeia Vulcan Stove Dimensions...

Page 16: ...d to product failure 6 Where can I get spare parts Your local Cast Tec stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Cast...