2.3) Menu Item “Transmission Protocol“
With this menu item the data output protocol can be selected.
Two different sentence formats can be selected:
-
$HCHDM,xxx.x,M*CS <CR> <LF>
-
$HCHDG,xxx.x,,,,*CS <CR> <LF>
“xxx.x“ is the transmitted magnetic heading and “CS“ for the check sum.
Select the required sentence and data transmission parameters with “Up/Down“ and
activate with “Menu/Enter“.
“HCHDM,4800,1/s”
Sentence:
Baud rate: Transmissions per second:
HCHDM
4800
1 transmission per second
HCHDG
38400
10 transmissions per second
30 transmissions per second
All transmissions are of 8 data bits, 1 stop bit and no parity.
2.4) Menu Item “Detector Alignment”
With this menu item the alignment of detector can be executed.
For installation of NETcourse it is necessary to align the detector to the magnetic
compass. For alignment loosen screws of detector a little bit, so that detector can be
turned slightly. Turn detector until displayed heading matches magnetic compass heading.
Fix the screws of detector.