NETcourse 

Page 10

 

Alterations/Errors reserved                                                                                                                                                        15/Wo/251D 
Cassens  &  Plath  GmbH,  Am  Lunedeich  131,  D-27572  Bremerhaven,  Germany,  tel.  +49  471  483  999  0,  fax  +49  471  483  999  10 

www.cassens-plath.de

[email protected]

  

 
 
3)
 

Error Messages/ Removing Errors 

 

If from time to time error message “No Detector Input Data” appears, this can be caused 
by an uncorrected heeling magnet of the compass. 
So please check if at all corrections (deviation adjustment) were done. If not remove or 
position heeling magnet as far as possible to the compass with detector. To find out how to 
do this please refer to the relevant operations manual of the compass or compass 
binnacle. 

 
 
 
 
 
 
 
 
 
 
 
 

 

Error Reason 

Remedy 

”Power Failure“,  
 

Main- /Emergency 
voltage below 18 VDC. 

Make sure power supply : 24 VDC. 

”Transmission Error“,  
 

Transmission error table 
not valid 

Switch off and on instrument. 
Carry out transmission error correction 
procedure (ref. “Compass Reset“). 

”No Detector Input 
Data“,  
 

Detector data not valid 

Make sure correct mounting of detector and 
right distance to compass. 
Make sure correct wiring of detector. 
Make sure that there are no magnetic 
interferences at detector location. 
Check correct function of detector by use of a 
multimeter *). 

No function 

 

Switch on instrument. 
Adjust dimmer to max. brightness to verify that 
power is connected. 
Make sure wiring and right voltage supply.  

No data transmission. 
NETcourse shows no 
error message.  

 

Make sure that data cables and connectors 
are in order. 
Interchange data cable A and B. 
Make sure that correct output data 
specification was selected. 

 

 *) Ref. to chapter „Pin Connection of Plugs/Connectors“ 
Measure resistance between: 
Cosine und Reference: 60 Ohm, Sine und Reference: 60 Ohm,  Sine und Cosine: 120 Ohm  
Exitation 1 und Exitation 2: 50 Ohm, Exitation 1 or Exitation 2 and Reference: not connected 
The values should be found within a tolerance of +/- 20%, else the detector might be defective.

Attention:

  The display shows existing operational errors and gives further 

information. Please follow this information and refer to the error 
shooting chapter of this operations manual. If the error cannot be 
removed in this way switch off the instrument and call the 
manufacturer.  
Please pay attention to each error message carefully, else proper 
operation cannot be guaranteed and safety of the vessel may be 
endangered. 

Summary of Contents for NETcourse

Page 1: ...al Magnetic Compass Converter CASSENS PLATH GmbH Manufacturers of Nautical Instruments Am Lunedeich 131 D 27572 Bremerhaven Germany Tel 49 471 483 999 0 Fax 49 471 483 999 10 sales cassens plath de www cassens plath de NETcourse ...

Page 2: ...t Errorlist 8 2 2 Menu Set Up Errorlist 8 2 3 Menu Transmission Protocol 9 2 4 Menu Detector Alignment 9 3 Error Messages Error Removing 10 4 Installation 11 4 1 Installation of Detector 11 4 2 Installation of Junction Box 12 4 3 Location of Detector and Junction Box within Compass Binnacle 12 5 Wiring 13 5 1 Power Supply 13 5 2 Connection of Junction Box 13 5 3 Connection of Data Output 13 5 4 Ex...

Page 3: ...1 D 27572 Bremerhaven Germany tel 49 471 483 999 0 fax 49 471 483 999 10 www cassens plath de sales cassens plath de 1 Drawings 1 1 Dimensions Flush mounting Weight 2 1 KG 1 2 Mounting of Control Unit Flush mounting cut out 225 mm x 125 mm 120 mm 220 mm 145 mm 245 mm min 110 mm 235 mm 85 mm ...

Page 4: ...assens plath de sales cassens plath de 1 3 System Overview Compass Mounting cylinder Detector CP102B Detector cable 1 5 m 5 wires screened with connector Junction box Detector cable 15 m 5 wires screened with connector RS 485 Data output with connector Emergency power supply 24VDC 4m 2 wires with connector Main power supply 24VDC 4m 2 wires with connector Control Unit ...

Page 5: ...7572 Bremerhaven Germany tel 49 471 483 999 0 fax 49 471 483 999 10 www cassens plath de sales cassens plath de 1 4 Control Unit Front Controls ERROR 1 LC Display 2 On Off switch 3 Dimmer 1 LC Display shows actual functions Menus or error messages 2 On Off switch 3 Backlight dimmer of LC display ...

Page 6: ...w cassens plath de sales cassens plath de 1 5 Control Unit Front Push Buttons Back To Operation LC Display Enter Up Down push botton push botton push bottons Back To Operation push botton Return to operation mode Up Down push botton Moves Menu one step up or down Enter push button Activates Menu mode Selects Menu LC Display Shows operation dialog and error messages ...

Page 7: ...15 Wo 251D Cassens Plath GmbH Am Lunedeich 131 D 27572 Bremerhaven Germany tel 49 471 483 999 0 fax 49 471 483 999 10 www cassens plath de sales cassens plath de 1 6 Control Unit Rear Grounding Detector RS 485 output Emergency voltage Main voltage ...

Page 8: ...ence of the direct reading of the magnetic compass and the heading as displayed by NETcourse This Menu item enables you to establish a errorlist This is only necessary in case too large transmission errors are recognized These transmission errors are caused by the direct interference of the corrector magnets to the detector so these errors are not a malfunction of the instrument but they result fr...

Page 9: ...ntence and data transmission parameters with Up Down and activate with Menu Enter HCHDM 4800 1 s Sentence Baud rate Transmissions per second HCHDM 4800 1 transmission per second HCHDG 38400 10 transmissions per second 30 transmissions per second All transmissions are of 8 data bits 1 stop bit and no parity 2 4 Menu Item Detector Alignment With this menu item the alignment of detector can be execut...

Page 10: ...of detector Make sure that there are no magnetic interferences at detector location Check correct function of detector by use of a multimeter No function Switch on instrument Adjust dimmer to max brightness to verify that power is connected Make sure wiring and right voltage supply No data transmission NETcourse shows no error message Make sure that data cables and connectors are in order Intercha...

Page 11: ...t possible If the correct distance is unknown there are two different ways do determine it 1 The magnetic moment the strength of the magnets of the compass is known This value will often be found in the compass certificate If for example the value is between 2 0 4 5 Am2 the correct distance between detector and magnet of card assembly is 110 mm If the exact location of the magnets inside the float...

Page 12: ... Junction Box The junction box allows easy removal of the compass from the binnacle and easy separation of detector cable 4 3 Location of Detector and Junction Box within Compass Binnacle Binnacle Compass Detector Distance Cylinder Cable with Connector Cable Junction Box Hood Attention Make sure that detector cable does not impair free movement of compass gimbal and that cables do not obstruct vis...

Page 13: ...erhaven Germany tel 49 471 483 999 0 fax 49 471 483 999 10 www cassens plath de sales cassens plath de 5 Wiring 5 1 Power Supply brown green brown green 5 2 Connection of Junction Box Connect color to color green gray white brown pink 5 3 Connection of Data Output White Data A Green Data B Mains Emergency ...

Page 14: ... electronics 1 For this fix the casing to the wall steel wall of the superstructure after removing insulating paint at the rear of the casing and the adjacent wall 2 If this is not possible use a massive copper wire and fix it on one side at the grounding screw of the casing and on the other side at the ship s steel hull Take the shortest way 3 If such a grounding is not possible or not successful...

Page 15: ... Connection of Plugs Connectors 7 2 Start Instrument and Check Operation Switch on the instrument after having completed installation works In the display you will see transmitting Now change to menu mode ref to chapter Menu Mode and choose the required data sentence format ref to Menu item Transmission Protocol 7 4 Check of Transmission Accuracy Check by comparing the heading of the connected uni...

Page 16: ...de sales cassens plath de 8 Pin Connection of Plugs Connectors As to be seen from rear of casing Power Supply 3 pin 24VDC identical for mains emergency supply 2 not connected 1 24VDC brown 3 Ground green Detector 5 pin 3 Reference white 2 Exitation2 pink 4 Cosine grey 1 Exitation1 brown 5 Sine green RS 485 RS 422 Data Output 4 pin 2 A white 3 B green 1 not 4 not connected connected ...

Reviews: