CASPR airande FY3803000 Owner'S Manual Download Page 1

CASPR 

Compact

Owner’s Manual

www.airande.global

Summary of Contents for airande FY3803000

Page 1: ...CASPR Compact Owner s Manual www airande global ...

Page 2: ...ears of trouble free service when it is properly maintained Even when properly cared for some parts of your CASPR COMPACT will need to be replaced periodically Replacement parts can be purchased from your authorized distributor or directly from CASPR Group www airande global ...

Page 3: ...appliance 3 This Appliance is only to be used with the detachable power supply unit provided 4 The method frequency of cleaning and necessary precautions to be taken are explained in detail on pages 12 16 a This Appliance must be disconnected from the supply before cleaning and maintenance b This Appliance contains a UV C emitter c Unintended use of this Appliance or damage to the housing may resu...

Page 4: ...3 Quickstart 4 Warnings 5 Setup Operation 6 Diagrams 8 Routine Maintenance 12 Troubleshooting 15 Limited Warranty 17 Records Specifications 18 Contents V IN M CC 01 03042021 ...

Page 5: ...mfortable sound level Leave the CASPR COMPACT in NORMAL Mode Screen will read PCO This is the standard mode for occupied rooms High mode is used for high burst of disinfection and it should not be used for more than one hour in any space 2 1 4 3 5 e the AWAY MODE for a higher level of disinfection when space is occupied Pressing the Away Mode key will start a timer 2 to 8 hours The CASPR COMPACT w...

Page 6: ...footage of ventilated space being treated To use this mode the ventilation system from the room should provide a minimum of three air exchanges per hour CAUTION Do not use AWAY MODE in occupied spaces Short term exposure to ozone levels exceeding 0 5 ppm can cause temporary adverse reactions including irritation in the eyes nose and throat shortness of breath chest pain and wheezing Pets children ...

Page 7: ...perating CASPR COMPACT 1 Connect the Power Cord to the Power Adapter and the Power Adapter Plug into the unit Check to be sure your power supply is properly assembled The Power Cord should be inserted far enough into the Power Adapter so that a space of only about 1 8 in is left between the widest part of the power cord and the edge of the Power Adapter 2 Insert the Power Plug into the wall outlet...

Page 8: ...ol Activating this setting will dim the display screen settings When to use AWAY Mode AWAY Mode generates ozone for deep cleaning an area This mode can be used for removing smoke cooking odors mold spores viruses and bacteria AWAY mode runs on a timer and once it completes the cycle it returns to Normal Mode Set AWAY Mode by pressing the AWAY Mode button Each time you press the button it will incr...

Page 9: ... Needle 1 Front Grille 2 Control Panel 3 Rear Cover Screw 1 Rear Cover Grooves 2 Power Adapter Inlet 3 Rear Cover 1 Unit Rear 2 Unit Front 3 1 2 3 Front of Unit Rear of unit Side of Unit Diagrams Unit 1 2 3 1 2 3 2 ...

Page 10: ...ll 1 Cell Nuts 2 Cell Connector 3 Power Cord 1 Power Cord Plug 2 Power Adapter 3 Power Adapter Plug 4 Purification Plate 4 Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Removed Power Supply 1 2 3 4 1 3 4 1 2 Unit ...

Page 11: ...nit control whether in ft or m Must be in high mode first LED Display sleep mode control Control Panel POWER FAN PURIFIER VAY l lOOC h Of YAU 8 Normal High Toggle 0 Power Button e Fan Speed Control 0 Purifier Level Control 0 Away Mode Toggle Fan Level Control Purification Level High Mode Away Mode 9 10 ...

Page 12: ...6 Fan Speed Indicator 1 2 Mode Indicator 3 4 Maintenance Reminders 5 Away Mode Warning 6 Mode Specific Display Normal Technology Indicator High Square Footage Indicator Away Mode Duration Indicator hours minutes 3 Away Mode High Mode Normal Mode ...

Page 13: ...hake excess water from the filter and let it dry for an hour before reattaching it Removing and Cleaning the Filter Assembly 1 Unit should be powered OFF and Power Cord should be disconnected when Cleaning Disassembling Reassembling Servicing 2 Remove the rear cover 3 Grasp the top of the Filter lift slightly and pull it away from the unit 4 Thoroughly rinse the filter with warm water Shake excess...

Page 14: ...ver carefully remove the Front Grille Screw and place where you will easily find it later 3 Remove the Front Grille by pushing up from the bottom of the Front Grille with your fingers Be careful to ensure the Ionization Needle in the top center of the front of the unit is not damaged 4 Clean the Front Grille using compressed air vacuum cleaner damp cloth or warm soapy water and set the Front Grill...

Page 15: ... the Remote Control If the Control Panel fails contact your distributor or CASPR Group www casprgroup com The Unit is Operating in High Mode or Away Mode but No Noticeable Purification is Being Produced 1 Ensure that the Purification Plate is clean See Next Page 2 The Purification Plate may not be working because it needs to be replaced Try installing a new Purification Plate 3 Check the electrica...

Page 16: ...ay not display the Replace Plate LCD reminder To order a replacement contact your distributor or Airande www airande global The Cell Does Not Light Up Ensure the Cell Power Connector is properly seated in the Cell Power Connector Outlet 1 Follow the instructions for removing the Rear Cover and Filter Assembly on Page 12 2 Check to see if the Cell Power Connector is properly inserted in the Cell Po...

Page 17: ...roof of purchase to your CASPR distributor All transportation charges on parts or units submitted under this Warranty shall be borne by purchaser Unless this Warranty is expressly renewed or extended by CASPR Group any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty For additional service informati...

Page 18: ...ing Power Supply Model Number FY3803000 Input 100 240VAC 50 60Hz 2 5A Output 38VDC 3A See the power supply label for certifications and warnings Cell Normal Mode Output Purification Plate High Mode Output 25 360mg ozone per hour Ionization Needle 24 to 30 KV 20 30 Khz Ion Generation Pulsator 6 KV DC Needle Ion Generator ...

Page 19: ...odel Number CASPR COMPACT Serial Number Distributor Name Distributor Phone Consumer Information CASPR Group declines all responsibility for all damages arising from improper use of the unit or in case of tampering with the unit ...

Page 20: ...19 www CASPRGROUP COM www airande global ...