Survey on the failures of the SOLENOID VALVE

Because sometimes in agriculture highly aggressive products are used, 
after various working hours the inner membranes of the solenoid valve 
can get worn. 

FAILURE:
The solenoid valve does not stop the fluid flow and the water comes out 
continuously from the nozzles.
SOLUTION:
Replace the membrane code 200.1006.5, and the gasket code 
300.601.32, that are located inside the solenoid valve body (see section 
plane).

FAILURE:
The fluid never comes out from the nozzles.
SOLUTION:
Check that the solenoid valve is connected to the power supply.
Check that the solenoid valve is connected to the water supply.
Check that the mobile core code 200.620.14 is not locked inside the 
fixed core.
Otherwise unlock and clean it and reinstall the solenoid valve.

At the end of the treatment, we recommend to wash thoroughly with 
clean water and at the end of the season to oil the mobile core, code 
200.620.14.

For any explanation relating to the STOPPER device, please apply to the 
producer Casotti Irroratori.

Summary of Contents for AQUILOTTO FC8-2

Page 1: ...2 SIDES code FC8 2 Version 2 2018 Instruction for the installation and the adjustment CASOTTI DEVICE TO INTERRUPT FLUID SPILLS BETWEEN TREES Made in Italy since 1966 Quello che mancava...

Page 2: ...all the optical reader WHAT IS INCLUDED WHAT IS NOT INCLUDED Continuous operation switch Working side selector Fuse Main switch ON OFF 5 pole sockets to connect the OPTICAL READERS Right timer Left ti...

Page 3: ...eter before the sprayer nozzles or the oscillating nozzles It must be installed so that its distance from the nozzles can be changed in order to open the fluid discharge earlier when needed The maximu...

Page 4: ...ce between the fluid discharge and the leaf decreases Repeat the same adjustments installing the optical reader on the opposite side 2 Turn the wheel of the 2 timers located on the control unit in the...

Page 5: ...URES 200 1 91 5 4 200 1 91 5 4 SC 200 1 91 5 4 NC 20 290 80 21 0 9A G1 2F 1 2 BSPM 89 5 1 04 54 5 1 5 1 27 30 mesh 1 0 C 80 C 201 1915 3 SC 27w coil 40bar 580 psi DIN43650 A ISO4400 PG9 connector with...

Page 6: ...e nozzles SOLUTION Replace the membrane code 200 1006 5 and the gasket code 300 601 32 that are located inside the solenoid valve body see section plane FAILURE The fluid never comes out from the nozz...

Page 7: ...12 13 PHOTOCELL technical information...

Page 8: ...stment AQUILOTTO 2 SIDES Translation of original instructions Version 2 2018 Information herein can be modified at any moment without notice Casotti is not responsible for omissions technical or editi...

Page 9: ...tori Via Cerreto 10 i 43035 Felino Parma Tel 39 0521831311 Fax 39 0521 336892 info casotti it www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti Made in Italy since 1966 Quell...

Reviews: