background image

8

9

166

COMANDI - COMPONENTISTICA

 / 

CONTROL UNITS - PARTS

M201

201.1915.3

12Vdc - 27w - 40 bar / 580 psi

200.1915.4

12Vdc - 10w - 20 bar / 290 psi

201.1915.3 SC

12Vdc - 27w - 40 bar / 580 psi

200.1915.4 SC

12Vdc - 10w - 20 bar / 290 psi

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.3 - 200.1915.3 SC - 200.1915.3 NC

bar

psi

l/min-1bar

USG pm-15psi

12Vdc

+-10%

A

 

B

mm

C

mm

D

mm

F

mm

G

mm

Fitro

strainer

40

580

80

21

2A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.4 - 200.1915.4 SC - 200.1915.4.NC

20

290

80

21

0.9A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

New

166

COMANDI - COMPONENTISTICA

 / 

CONTROL UNITS - PARTS

M201

201.1915.3

12Vdc - 27w - 40 bar / 580 psi

200.1915.4

12Vdc - 10w - 20 bar / 290 psi

201.1915.3 SC

12Vdc - 27w - 40 bar / 580 psi

200.1915.4 SC

12Vdc - 10w - 20 bar / 290 psi

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.3 - 200.1915.3 SC - 200.1915.3 NC

bar

psi

l/min-1bar

USG pm-15psi

12Vdc

+-10%

A

 

B

mm

C

mm

D

mm

F

mm

G

mm

Fitro

strainer

40

580

80

21

2A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.4 - 200.1915.4 SC - 200.1915.4.NC

20

290

80

21

0.9A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

New

SOLENOID VALVE - technical features

166

COMANDI - COMPONENTISTICA

 / 

CONTROL UNITS - PARTS

M201

201.1915.3

12Vdc - 27w - 40 bar / 580 psi

200.1915.4

12Vdc - 10w - 20 bar / 290 psi

201.1915.3 SC

12Vdc - 27w - 40 bar / 580 psi

200.1915.4 SC

12Vdc - 10w - 20 bar / 290 psi

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.3 - 200.1915.3 SC - 200.1915.3 NC

bar

psi

l/min-1bar

USG pm-15psi

12Vdc

+-10%

A

 

B

mm

C

mm

D

mm

F

mm

G

mm

Fitro

strainer

40

580

80

21

2A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

CARATTERISTICHE TECNICHE / 

TECHNICAL FEATURES - 200.1915.4 - 200.1915.4 SC - 200.1915.4.NC

20

290

80

21

0.9A

G1/2F.

1/2"BSPM.

89.5

104

54

51.5

127

30 mesh

-10°C - +80°C

New

201.1915.3 SC 27w coil - 40bar (580 psi) DIN43650 A - ISO4400 
PG9 connector without cable

Max. operating pressure: 40 bar
Weight: 1.1 kg 
Materials: brass - stainless steel - FKM seals - high resistance plastic 
materials
Use: on airblast sprayers. Industrial applications
- normally closed (NC) 12Vdc servo operated diaphragm solenoid 
valve. Instantaneous shut-off;
- low power consumption continuous duty incapsulated revolving coil 
(H class 180°) with double FKM seal;
- oversized pilot and internal holes. Niploy processed stainless steel pilot 
unit with FKM seal;
- single unit line use. Two inlets and two outlets.

Summary of Contents for AQUILOTTO FC8-2

Page 1: ...2 SIDES code FC8 2 Version 2 2018 Instruction for the installation and the adjustment CASOTTI DEVICE TO INTERRUPT FLUID SPILLS BETWEEN TREES Made in Italy since 1966 Quello che mancava...

Page 2: ...all the optical reader WHAT IS INCLUDED WHAT IS NOT INCLUDED Continuous operation switch Working side selector Fuse Main switch ON OFF 5 pole sockets to connect the OPTICAL READERS Right timer Left ti...

Page 3: ...eter before the sprayer nozzles or the oscillating nozzles It must be installed so that its distance from the nozzles can be changed in order to open the fluid discharge earlier when needed The maximu...

Page 4: ...ce between the fluid discharge and the leaf decreases Repeat the same adjustments installing the optical reader on the opposite side 2 Turn the wheel of the 2 timers located on the control unit in the...

Page 5: ...URES 200 1 91 5 4 200 1 91 5 4 SC 200 1 91 5 4 NC 20 290 80 21 0 9A G1 2F 1 2 BSPM 89 5 1 04 54 5 1 5 1 27 30 mesh 1 0 C 80 C 201 1915 3 SC 27w coil 40bar 580 psi DIN43650 A ISO4400 PG9 connector with...

Page 6: ...e nozzles SOLUTION Replace the membrane code 200 1006 5 and the gasket code 300 601 32 that are located inside the solenoid valve body see section plane FAILURE The fluid never comes out from the nozz...

Page 7: ...12 13 PHOTOCELL technical information...

Page 8: ...stment AQUILOTTO 2 SIDES Translation of original instructions Version 2 2018 Information herein can be modified at any moment without notice Casotti is not responsible for omissions technical or editi...

Page 9: ...tori Via Cerreto 10 i 43035 Felino Parma Tel 39 0521831311 Fax 39 0521 336892 info casotti it www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti Made in Italy since 1966 Quell...

Reviews: