Section C. ACS Operations Overview
Button/Switch
Manual/Auto
Function
Manual/Auto
Both
Switches between auto and manual
CO
2
Purge
Auto
Indicates when pre-purge is open
#1-5 Can Fill
Auto
Indicates when valves are open
Filler Stop Button
Auto
Normal stop of the filler operation in auto mode
(seamer continues to run)
Lid Dispense
Both
Dispenses a lid
Clean in Place Indicator
Switch (CIP)
Auto
Lights up when clean-in-place running; Turn the
clean-in-place function on or off
Top Up Indicator Switch
Auto
Lights up when top up is running; Turn top up on or
off, depending on position
Top Up Timer
Auto
Sets the amount of time the top up will last for
Foam Valves Indicator
Switch
Auto
Lights up when foam valves running; Turn foam on
or off, depending on position
Foam Valve Timer
Auto
Sets the amount of time the foam valves will be on
for
Start Button
Auto
Start the equipment in auto mode; Lights up when
running
Vibrator Off/On Switch
Both
Turn on the shaker or depal table vibrator
Table 2 HMI Panel – Main Page – Button Functions
C.2.2
HMI Panel – Filler Page
Manually Control Can Fill, CO2 Purge, Gate, Lid Purge.
Figure 8 HMI Panel – Filler Page screenshot