EQ2006 

CONTROL BOX GATE’S OPENING - 2 MOTORS SINGLEPHASE 230VAC 

 
OPERATION PROGRAMS 
With the combination of the  mini DIP switches it is possible to program the gate’s operation and of the auxiliary services. 
STEP BY STEP, SEMIAUTOMATIC, AUTOMATIC, DEAD-MAN, PEDESTRIAN, SHORT CLOSING IMPULS, TIMER, SLOW-
DOWN MOTORS, POWER STARTING, TEST PHOTOCELLS, MOTORS INDIPENDENT OR UNIFIED, MEMORISATION OF 
WORK’S TIME, REVERSE, OPERATION TYPE B. 
Warning ! To enter a new program, the control box must be zero set in order to allow the storage  of the new instructions replacing 
the previous one. For such purpose it is possible  to follow  two different procedures:  
1)  set the  wanted instructions through the programming devices (DIP) cut out the supply voltage   for a few  seconds  and  then  
     switch-on the supply voltage. The control box  must effect one cycle complete and then is  ready. 
2)  set the wanted instructions  and effect  a  new  cycle complete. After the one cycle (opening-closing) the control box is ready. 
FUNCTIONS: 
STEP BY STEP  (S2 DIP 2 OFF)  at every impulsion of  start the control box :open-stop-close-open……. 
SEMIAUTOMATIC  (S2 DIP 2 ON)  at every impulsion of start the control box open.for the closing it is necessary another impulsion 
of start. (S1 DIP1 OFF)  or automatically (S1 DIP1 ON). 
AUTOMATIC  (S2 DIP 1 OFF, DIP 2 ON, S1 DIP 1 ON)  At every impulsion of start the control box open.  
Then close automatically After the adjusted time. 
DEAD-MAN  (S2 DIP 1 ON, S1 DIP1 OFF, DIP 3 OFF)  push bottons separate. When the push bottons are pushed, the motors runs 
when are released ,the motors stop. The limit switches are in function. 
PEDESTRIAN  it is possible to open, partially, the gate, (see the planning menu) and after the cycle is effected following the 
program selected by the DIP. During the pedestrian closing the photocell opens the gate.The closing-time is equal to the total work’s 
time,so that the gate can close fully. 
SHORT CLOSING IMPULS  (S1 DIP 6 ON)  at every opening-start (when the gate is closed) the motors runs  in closing (few instant) 
to permit the easier release of the electrolock, then the motors  runs in opening. 
TIMER  it possible to connect a timer to opening the gate for the time during the contact of the  timer is activated S2 DIP 1 OFF, DIP 
2 ON, S1 DIP 1 ON DIP 3 ON.  ON.When the contact of the timer is released,the gate close after the time selected. 
SLOW-DOWN-MOTORS  it is possible to set the slow down motor in opening and closing during the planning , but 2 sec. before the 
closing,the motors have max. power for an easy locking of the electrolock (S2 DIP 3 ON). Do not use with motor over 350W. The 
speed of deceleration can be regulated with dip-switch 9 S1, DIP9 ON high speed, DIP 9 OFF low speed. 
The moment in which the slow-down starts can be differentiated between the opening and the closure. 
POWER STARTING  (S2 DIP 4 ON, S1  DIP 6)  at every impulsion of start the motors start at the max. power for 1,5 sec (S1 DIP 6 
OFF) or for 3 sec. (S1 DIP 6 ON) and then, runs at the power adjusted by P1 e P4. 
TEST PHOTOCELLS  (S3 DIP 1 e DIP 2 PLUGS 32-33)  at every cycles the control box verify if the photocell’s receiver is in 
fonction. 
MOTORS INDEPENDENTS OR UNIFIED  (S1 DIP 5)  the motors can have  the work’s time independent (double sliding, double 
barrier etc..) also the operation of the limit switches is independent of each  (S1 DIP 5 OFF  adjust  P1 e P4), the pedestrian works 
on 1 motor only. Or the motors can have the work’s time unified  (2 motors on a garage door ,etc..).So, only one limit switch stop the 
two motors (S1 DIP 5 ON adjust P1 ), the pedestrian works on both motors. 
MEMORISATION OF WORK’S TIME  the control box memorize the time of opening and closing. So, the motors runs for the right 
time +few seconds. And if the gate re-open when is in closing the motors not runs for  a long time. 
REVERSE  (S3 DIP 4 OFF motor 1, S3 DIP 5 OFF motor 2)  survey obstacle along the run of the gate (see chapter 7). 
OPERATION TYPE B  (S3 DIP 3 ON ) it trains  the card for signal clinking and it changes  the work formality of the input Safety 
edge 1 and  2. 
INSTALLATION 2 MOTORS IN THE ONE LEAF  (ex.garage door-big swing): 
To connect the 2 motors one to the plug M4 and the second to the plug M5.  Select the Dip-switch S1 ON "working time unified for 
the 2 motors on M1" and follow the program for one motor (chap. 6.1) 
TECHNICAL SPECIFICATIONS 
Control unit power: 

                           230VAC   Hz 50/60 

 

Motor output:  

       

     2 x 500W   

(tryac 16A - Relais motor max 10°) 

Accessories power:  

    

 

     24 VAC - 500 mA  (the sum absorptions clamps 32-33-34 e 29-30) 

Electrolock power:  

    

 

     12 VAC - 1 A 

Environmental operatine temperature:               -5°C / + 60 °C 
Warning !  

 

Do not use with motor over 350w:  slow-down-motors,  power starting,  reverse. 

 

When the control panel is used with the relays or teleruptors connected to the output motor for powers motors up to 350W, 

regulate the push motor (P1 and P4) to the maximum power. 

 

 

WARNING! 

Before installing, thoroughly read this manual that is an integral part of this Kit. Casit declines any 

responsibility in the event current standards in the country of installation are not complied with 

 

 

GB 

Summary of Contents for EQ2006

Page 1: ...F DIP 2 ON S1 DIP 1 ON DIP 3 ON ON When the contact of the timer is released the gate close after the time selected SLOW DOWN MOTORS it is possible to set the slow down motor in opening and closing du...

Page 2: ...common to the clamp 9 closing to the clamp 10 M6 11 12 Light of courtesy clean contact N O max 230V 4 Amp see S3 dip 8 M7 13 14 Output 12Vdc max 200 mA 14 15 Input N C SAFETY EDGE 1 In opening it arre...

Page 3: ...o the intervention of the safety edge 1 The flashing led L2 points out the condition of triac TH1 pilot motor 1 in damage L3 SAFETY EDGE 2 it switch on to the intervention of the safety edge 2 The fla...

Page 4: ...en the gate is closed and foto 1 obscurated the gate not open during the closing and foto 1 obscurated the gate stop and reopen when the foto1 is liberated in this operation is activated also the elec...

Page 5: ...e memorization involves to repeat the procedure of the first setting because the times of work and the setting of the reverse changes S2 dip 9 according to the used motors ON two motors OFF one motor...

Page 6: ...nal portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole stroke with normal speed maintain pressed...

Page 7: ...aintain pressed PS1 and release it just at the end of the opening when limit switch is working FCA 1 Hold pressed the key PS1 to plan the last portion of opening for motor 1 in deceleration and releas...

Page 8: ...motor 1 WARNING If you want to plan the final portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole...

Page 9: ...TIME BRAK Inside the planning menu press the push button PS3 to go in the parameter Pedestrian time break The state of the leds represented to the left side points out that it is in the menu related t...

Page 10: ...onnect the positive pole of the leds to the source of feeding and the negative pole of every leds to the clamp F of the relative terminal block Naturally the negative one of the source of feeding must...

Page 11: ...celeration ON strength range high OFF strength range low respectively on motors 1 and 2 During the reverse intervention a short flash red is gotten on the led REV 1 if it intervenes on the motor 1 or...

Page 12: ...the bridge The motors limit switches are missing of is not present the bridge among the input 20 21 23 24 and the commune Verify the limit switches of the motor or the presence of the bridge A key se...

Page 13: ...th several wires and always separate the power from the low tension Connect wires to the control box from the bottom through pass cables only MAINTENANCE To ensure product efficiency it is essential t...