background image

E-16

Power ON/OFF

Moving and Cleaning

When moving or cleaning the product, always shut down the main unit before turning 

OFF the main power switch. Also, always make sure that the main power switch is OFF 

before removing or inserting the plug.

1.  

Shut down the main unit.

Using the OFF Switch

(1) 

Press and hold the OFF switch for 
approximately 1 second.

(2) 

Touch the “Power off” display.

Using the Power Switch

(1) 

Press and hold the power switch for 
10 seconds or longer.

(2) 

Touch the “Power off” display.

2.  

Turn the main power switch OFF.
Remove the main power switch cover 
and turn OFF the main power switch.

+

The data may be damaged when above procedure is not done properly. Do not use the 

main power switch to turn the main unit ON/OFF during normal use.

3.  

Remove the power plug.

4.  

After moving or cleaning the product, 

plug in the power plug and switch ON 
the main power switch.

OFF

Main power switch

Main power switch cover

Summary of Contents for V-R7100

Page 1: ...nçais Español English User s Manual Manual del usuario Manuel de l utilisateur Bedienungsanleitung Touch Screen Terminal Terminal de pantalla táctil Borne de l écran tactile Touchscreen Terminal V R7100 V R7100 C ...

Page 2: ... E 11 Name of Parts and What They Do E 12 Power ON OFF E 15 Daily Use E 15 Moving and Cleaning E 16 Description of the Indicator E 17 Adjusting the Angle of the Display E 18 When the Drawer Does not Open if using the optional CASIO drawer E 18 Installation E 19 Name of Parts and What They Do E 20 Connecting the Power Supply and Various Devices E 22 Connecting the Drawer cable E 22 Connecting the A...

Page 3: ... are indicated by Warning Using the AC power supply Do not twist pull heat modify or place anything heavy on the power cord This may damage the power cord and result in fire or electrical shock Contact the dealer or the CASIO service representative when the power cord is dam aged wire is exposed or disconnected Using the power cord in such condition may result in fire or electrical shock Securely ...

Page 4: ...ble locations such as on an unsteady table or an inclined location It could fall and cause injure Do not place in a location with high humidity or dust This may result in fire or electrical shock Do not place in a location exposed to oil smoke or humidity such as close to cooking table or humidifier This may result in fire or electrical shock Do not place in a location close to heating devices suc...

Page 5: ...awer If using the optional CASIO drawer Take caution with the face of a child or pregnant person when opening a drawer Do not lean on the drawer when the drawer is opened It could fall and cause injure Cleaning Unplug the power plug from the outlet for safety when cleaning Clean the blades and surrounding of the blades of the power plug with a dry cloth at least once a year Dust accumulation may r...

Page 6: ... si ce n est selon les procédures mentionnées pour le multi transmetteur FCC IC ou décrites dans la documentation Caution Exposure to radio frequency radiation To comply with FCC RF exposure compliance requirements this device must not be co located or operating in conjunction with any other antenna or transmitter except in accordance with the FCC multi transmitter product procedures or as describ...

Page 7: ...des 5 250 5 350 MHz et 5 470 5 725 MHz doit se conformer à la limite de p i r e iii le gain maximal d antenne permis pour les dispositifs utilisant la bande 5 725 5 825 MHz doit se conformer à la limite de p i r e spécifiée pour l exploitation point à point et non point à point selon le cas De plus les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux c à d qu ils ont...

Page 8: ... conformity may be consulted at http world casio com V R7100 Products are for distribution within all member states of the EU 0984 Laite on liitettävä suojamaadoituskostkettimilla vaurstettuun pistorasiaan Apparatet må tilkoples jordet stikkontakt Apparaten skall anslutas till jordat nätuttag The main plug on this equipment must be used to disconnect mains power Please ensure that the socket outle...

Page 9: ...t uses high precision and substantial number of compo nents which commonly cause a small number of the pixels not to light or to remain lit all the time This is due to the characteristics of LCD panel yield in accuracy over 99 99 and permissible 802 11a n Restrictions This product is for indoor use only when using channels 36 40 44 48 52 56 60 or 64 5150 5250 MHz To ensure compliance with local re...

Page 10: ...t of this manual was created with all possible care but please contact us if there is any unclear point mistake omission etc in this manual The screen or illustration used in this manual may be different from the actual product The keys and icons are described in simplified manner Weld Line The line on the exterior of the product is called weld line which is created at the time of plastic forming ...

Page 11: ...E 10 Confirming the Accessories Stand Display AC adaptor Drawer cable Connector cover Dust cover Power cord US only User s Manual this manual Warranty US only ...

Page 12: ...n method of this product after the installa tion Name of Parts and What They Do E 12 Power ON OFF E 15 Daily Use E 15 Moving and Cleaning E 16 Description of the Indicator E 17 Adjusting the Angle of the Display E 18 When the Drawer Does not Open if using the optional CASIO drawer E 18 ...

Page 13: ...and Front 2 1 3 4 5 1 Indicator Display the status of the power supply 2 Power switch Turn the power ON It will display the shutdown menu when pressed and held Switch the ON and OFF of the screen display 3 Microphone Input the audio 4 Touch screen panel Display each menu Used for data input 5 Dallas key For operators to sign on and off Factory option ...

Page 14: ...n connecting the power supply or various devices 7 Speaker Output the audio 8 Main power switch cover Cover for the main power switch 9 Tilt knob Adjust the angle of the display 10 Earphone jack cover Cover for the earphone jack 11 Side cover Cover for various switches and slots at the left side ...

Page 15: ...5 16 12 OFF switch Turn the power OFF 13 USB host port for maintenance A port for maintenance Do not use 14 SD SDHC memory card slot for maintenance A slot for maintenance Do not use 15 Reset switch for maintenance A switch for maintenance Do not use 16 Earphone jack Connect the earphone ...

Page 16: ...ower ON 1 Press the power switch The screen will turn on Turning to sleep mode 1 Press the power switch while the power is ON The screen will turn off The screen is turned off but the main body is operating while in sleep mode Turning the Power OFF shutdown 1 Press and hold the power switch for 10 seconds or longer 2 Touch the Power off display ...

Page 17: ...ch the Power off display Using the Power Switch 1 Press and hold the power switch for 10 seconds or longer 2 Touch the Power off display 2 Turn the main power switch OFF Remove the main power switch cover and turn OFF the main power switch The data may be damaged when above procedure is not done properly Do not use the main power switch to turn the main unit ON OFF during normal use 3 Remove the p...

Page 18: ...tus Green light is ON Power is ON screen is ON Orange light is ON Power is ON screen is OFF Green and red lights flashing with screen ON Red and orange lights flashing with screen OFF Memory protection battery not charged Do not turn OFF the main power switch or remove the power plug with the display in this state OFF Power is OFF shutdown ...

Page 19: ...angle of the display There may be a risk of injury When the Drawer Does not Open if using the optional CASIO drawer If the drawer fails to open due to a power cut or fault open it by doing the following If you are using a CASIO optional M size drawer it can be opened by moving the drawer release lever tab on drawer bottom The drawer will not open if it has been locked with the drawer lock key Unlo...

Page 20: ...connected the cables of the product to move it and do not know how to reconnect them Name of Parts and What They Do E 20 Connecting the Power Supply and Various Devices E 22 Connecting the Drawer cable E 22 Connecting the AC Adaptor E 23 Connecting Other Devices E 23 Preparing the Stand E 25 Setting the Stand and the Display E 26 Installation features E 28 MCR Unit VA B46MCRE Installation E 29 ...

Page 21: ...onnect device such as customer display etc 17 COM2 port Connect device such as printer etc 18 COM1 port Connect device such as printer etc 19 Drawer port for 24 V Connect the drawer cable 20 Drawer port for 5 V Connect the drawer cable 21 DC jack Connect the AC adaptor 22 USB host port Connect the USB device ...

Page 22: ... stand 24 SD SDHC memory card slot Insert the SD or the SDHC memory card 25 HDMI port Connect the HDMI device 26 LAN port Connect the LAN cable 27 Micro USB client port Connect the micro USB device 28 USB host port Connect the USB device MCR Unit Installation Parts 29 30 29 MCR unit connector Connect the MCR unit connector 30 MCR unit cover Cover the MCR unit connector ...

Page 23: ...t dirty or scratched POINT When using an optional printer SD card and HDMI device connect them in the follow ing order The devices we recommend that you connect first have large connectors If you do not connect these first they may be obstruct the connection of other devices and prevent such work being performed Order of Connection 1 Devices connecting to the COM1 COM2 and COM3 ports 2 SD card 3 H...

Page 24: ...onnecting Other Devices Connect the optional device to the following connector Option Connector Remote printer UP 400B UP 370B COM1 COM2 COM3 port Customer display VA B60D COM2 COM3 port Expansion I F box VA B20EB USB host port For details refer to the User s Manual for each option Connecting the Printer Cable 1 Connect the printer cable plug with screws to the COM1 port located within the back of...

Page 25: ...ithin the back of the display Connecting the HDMI Device 1 Connect the HDMI cable to the HDMI port within the back of the display 3 After completing the connection of all devices you plan to use install the supplied connector cover with 3 screws During installation take care not to trap the connected cable between the connector cover and the display ...

Page 26: ... shown 2 Raise the upper part of the stand Then while holding it steady secure it by tightening the tilt knobs one side at a time in the directions shown Always loosen the tilt knob when moving the stand Moving without loosening the tilt knob will result in malfunction 3 Remove the rear cover by pressing at the locations marked A and sliding in the direction of the arrow A A ...

Page 27: ...es into the stand passing them through the opening Remove the cutouts at the 4 locations in the stand base with pliers and pull the cables through Do not insert fingers into the cutout This may result in injury 3 Hook the display onto the tab on the stand and adjust the routed cables so they will not sag too much or be too tight Arrange the cables so they will not overlap and fasten with the cable...

Page 28: ...over to the stand in the direction of the arrow 6 Loosen and remove the screws for the 3 cable fasteners at the bottom of the stand with a Phillips screwdriver 7 Adjust the routed cables so they will not sag too much or be too tight Arrange the cables so they will not overlap and fasten with the cable fastener and secure with a screw ...

Page 29: ... steady secure it by tightening the tilt knobs one side at a time in the directions shown 9 Connect the AC adaptor with the power cord and plug into a power outlet Installation features A screen for customers can be installed To do so remove the cutout in the base of the stand with pliers Cutout ...

Page 30: ...h OFF and remove the plug from the power outlet 1 Remove the MCR unit cover with a Phillips screwdriver etc and connect the MCR unit connector 2 Install the MCR unit as shown in the illustration and secure it with 2 screws supplied During installation take care not to trap the connected cable between the MCR unit and the display For how to install a printer or other optional device refer to the Op...

Page 31: ...fe 5 years used at 25 C Charge time Full charge in 3 hours used at 25 C Power supply power consumption 120 V ac 10 V 50 60 Hz 0 5 A 230 V ac 10 V 50 60 Hz 0 3 A 220 V to 240 V ac 10 V 50 60 Hz 0 3 A External interface Side of display SD SDHC memory card slot x 1 USB host port x 1 Earphone jack x 1 Rear of display COM port x 3 Drawer port x 2 DC jack x 1 USB host port x 3 SD SDHC memory card slot x...

Page 32: ...B UP 370B Customer display VA B60D Customer display serial cable 40 cm QT 6061CB B Customer display serial cable 5 m QT 6062CB B Expansion I F box VA B20EB Drawer M size DL 2814 DL 2815 DL 2436 L size DL 3624 DL 3625 Drawer extension cable VA B30CB MCR unit VA B46MCRE ...

Page 33: ...MEMO E 32 ...

Page 34: ......

Page 35: ......

Reviews: