![Casio QW-5311 Service Manual & Parts List Download Page 8](http://html.mh-extra.com/html/casio/qw-5311/qw-5311_service-manual-and-parts-list_2572102008.webp)
QW-5311
– 6 –
5-3. SETTINGS AFTER AC
Function
Settings
After AC Mode
Close the back cover or short-circuit the MP terminal. When you
operate any button, EEPROM is read after one second and then
the watch goes into the Timekeeping mode. ( Aligning the hands
to their baseline positions is needed. )
Timekeeping Mode
Date and time: Friday, January 1, 2010 12:00:00 AM
Home City Code : TYO (UTC+9)
DST: AUTO
Mode Hand: “FR” position
World Time
WT City Code: UTC
Date and time: December 31, 2009 3:00:00 PM
DST: AUTO
Mode Hand: “WT” position
Stopwatch
Setting: “Reset” (00’00’’00)
Mode Hand: “ST” position
Countdown Timer
Setting: “Reset” (10’00)
Start Time: 10 minutes 00 second
Mode Hand: “TR” position
Alarm
Time: 12:00 AM
Alarm: OFF
Mode Hand: “AL” position
Digital Compass
Setting: Direction reading