Symptoms
Probable Causes
– Improper connection of the network cable
■
Check the RJ-45 connector installed on the NET port of the multi-I/O
expansion card.
Network function is not
– Loose connection between the multi-I/O (NET) expansion card and the
working
CPU card.
■
Pull out the multi-I/O expansion card from the CPU card then re-install
it back. If symptoms persist, replace the multi-I/O expansion card.
– Defective CPU card
■
Replace the CPU card of the System.
– Loose connection between the cash drawer connector board and multi-
I/O expansion card
■
Pull out the cash drawer connector board from the multi-I/O expansion
Cash drawer ports not
card then re-install it back. If symptoms persist, replace the cash drawer
functioning
connector board.
– Defective multi-I/O expansion card
■
Replace the multi-I/O expansion card of the system.
– Defective CPU card
■
Replace the CPU card of the System.
– Loose connection between the multi-I/O (PRN) expansion card and the
CPU card.
Printer port is not
■
Pull out the multi-I/O expansion card from the CPU card then re-install it
working
back. If symptoms persist, replace the multi-I/O expansion card.
– Defective CPU card
■
Replace the CPU card of the System.
– Loose connection between the keyboard /mouse/FDD expansion card
and the CPU card.
Keyboard/Mouse/FDD
■
Pull out the keyboard/mouse/FDD expansion card from the CPU card
are not functioning
then re-install it back. If symptoms persist, replace the keyboard/mouse/
FDD expansion card.
– Defective CPU card
■
Replace the CPU card of the System.
– Inverted connection (from HDD to CPU card) of the 44-pin HDD cable
■
Adjust and install the HDD cable properly.
HDD is not working
– Defective hard drive
■
Replace the hard disk drive of the system.
– Defective CPU card
■
Replace the CPU card of the System.
– Improper connection (from CN1 of touchscreen control board to COM3 of
the multi-I/O expansion card) of the 10-pin touchscreen control cable
Touchscreen feature is
■
Adjust and install the touchscreen control cable property.
not functioning
– Loose power connection on CN2 of the touchscreen control board.
properly
■
Pull out the power cable on CN2 then re-install it back. If symptoms
persist, consult CASIO engineers.
– Defective touchscreen control board
■
Replace the touchscreen control board of the system.
Summary of Contents for QT-7300 Series
Page 1: ...SERVICE MANUAL ELECTRONIC CASH REGISTER without price QT 7300 EX 963 MAY 2001 ...
Page 11: ... 9 11 Release the 9 screws of the Mother board Then remove the Mother board 1 2 3 4 5 6 7 8 9 ...
Page 84: ... 82 10 DRAWER DL 2773 M Type ...
Page 86: ... 84 DL 2915 M Type ...
Page 88: ... 86 DL 3615 L Type ...
Page 90: ... 88 11 DRAWING ...