— 72 —
9-3 System error code
All error codes are contained in the list below. These error codes are displayed or printed on error log
report.
Error code
Meaning
0010
Handler access error (software)
0011
Cannot execute handler (system configuration)
0012
Break by PC
0013
Break by ECR
0014
DSR off before receiving command packet
0015
Receive illegal command number of command packet
0016
Receive illegal character
0017
Send error (hardware)
0018
Receive error (hardware)
0019
Receive illegal data packet
0020
No response error
0021
Receive illegal command phase
0022
Received illegal packet
0023
CNET receive error
0024
Illegal termination by sender
0025
Received illegal packet during receiving data packets
0026
Not enough data packets received
0040
No “H” information
0041
No “I” information
0042
No “F” information
0044
Illegal packet format
0045
No file exists
0046
Illegal block
0047
Illegal command packet
0048
Illegal command No. (Not CMD)
0049
Illegal command No. (Not DATA)
0050
Sequence error
0051
Turn off DSR signal
0052
Received cancellation
0053
Retry over while waiting command
0054
Retry over while waiting EOT
0055
Retry over while waiting data
0056
Received EOT
0057
Retry over while waiting ACK
0058
Retry over while sending data
0059
Retry over while waiting “C”
0060
Retry over while sending response
0061
Retry over while excluding
0064
Break end
0065
Error during printing report header
0066
Error during printing report data
0067
Error during printing report data in work file
0068
Error during printing report data in consolidation file
0069
Work file clear error
0070
Consolidation file clear error
0071
Z lock error
0072
Z clear error
0073
Z lock release error
0074
Error during accumulating to consolidation file
0075
Error during copying report data from terminal memory to work
0076
Error during copying stock data to terminal memory
0077
Z lock error on satellite terminal
0078
No appropriate file is exist on satellite terminal during collection/consolidation
Summary of Contents for QT-6100
Page 1: ...SERVICE MANUAL ELECTRONIC CASH REGISTER without price QT 6100 EX 819 AUG 2008 QT 6100 ...
Page 67: ... 65 8 11 ETHERNET CONTROLLER IC28 LAN91C113 8 11 1 Pin Assignment 8 11 2 Block Diagram ...
Page 92: ... 90 11 PCB LAYOUT MAIN PCB E819 1 PCB TOP VIEW ...
Page 93: ... 91 MAIN PCB E819 1 PCB BOTTOM VIEW ...
Page 94: ... 92 INTERFACE PCB E819 S1 PCB TOP VIEW BOTTOM VIEW LED PCB E820 LED PCB TOP VIEW BOTTOM VIEW ...
Page 108: ... 106 Model Name Board No Drawing No CASIO COMPUTER CO LTD QT 6100 EX 819 E820 LED LED ...
Page 120: ... 118 EXPLODED VIEW QT 6060D 2 11 17 14 15 20 Sales Option 16 5 6 12 13 18 19 8 7 10 3 1 4 9 5 ...
Page 135: ... 133 18 DRAWER DL 3616 ...
Page 137: ... 135 19 DRAWER DL 3617 ...