— 6 —
TP2(CP221)
TP7(CP207)
VR200
TP3(CP245)
TP4(CP240)
TP8(VCOM)
TP1(CP113)
VR740
VR303
TP5(CP323)
TP6(CP311)
VR300
T300
IF Pad
VCC2-1 Voltage Setting
Input
Input
Input
Output
Output
Connection Point
Signal
Connection
Point
Adjust
Result
Adjust to obtain a 4.50
±
0.02 V
reading on the voltmeter.
Voltmeter
VR100
TP1
TP1
16-169
Equipment Connection / Adjustment Procedure
Bottom View
Output
Voltmeter
EV-500
set