![Casio Celviano AP-40 Service Manual Download Page 15](http://html1.mh-extra.com/html/casio/celviano-ap-40/celviano-ap-40_service-manual_2569904015.webp)
— 13 —
2.
No sound
3.
Distorted sound
Does the power indicator
light up?
Check the main volume.
Is it OK?
Does the demo tune sound?
Replace keyboard PCBs.
Disconnect CA and CB
connectors on the main PCB.
Follow "No power"
troubleshooting.
No
Yes
Yes
Yes
No
No
Replace main volume.
Press Demo button.
Replace the main PCB.
Check the voltage selector.
Is it at proper position?
No
Yes
Replace the main PCB.
Set the voltage selector at
proper position.
Summary of Contents for Celviano AP-40
Page 1: ...DIGITAL PIANO AP 40 AP 40 AUG 2000 Ver 1 Oct 2000...
Page 13: ...11 PRINTED CIRCUIT BOARD JCM435 MAIN Top View Bottom View...
Page 20: ...18 STAND 40 39 R 9 R 8 R 7...
Page 26: ...24 8 Switch LED Controller 7 6 Console PCBs JCM434 CN1M...
Page 27: ...25 Console PCBs JCM434 CN2M...
Page 28: ...26 Keyboard PCB JCM887T KY1M...
Page 29: ...27 Keyboard PCB JCM887T KY2M...
Page 30: ...28 Keyboard PCB JCM887T KY3M...