![Casio Celviano AP-40 Service Manual Download Page 14](http://html1.mh-extra.com/html/casio/celviano-ap-40/celviano-ap-40_service-manual_2569904014.webp)
— 12 —
TROUBLESHOOTING
1.
No power
Check fuse F101.
Is F101 blown up?
Check fuses F402, F403, and F404.
Are the fuses blown up?
Are the voltages 40 V AC
and 8 V AC?
Is it OK?
Is it OK?
Measure output voltages of
the transformer.
Replace the transformer.
No
No
Replace F402, F403, and F404.
Yes
Yes
No
No
Yes
Yes
Yes
Replace main PCB.
No
Replace the power switch.
Set the voltage selector at
proper position.
Check position of voltage
selector.
Check the power switch.
Replace F401.
Summary of Contents for Celviano AP-40
Page 1: ...DIGITAL PIANO AP 40 AP 40 AUG 2000 Ver 1 Oct 2000...
Page 13: ...11 PRINTED CIRCUIT BOARD JCM435 MAIN Top View Bottom View...
Page 20: ...18 STAND 40 39 R 9 R 8 R 7...
Page 26: ...24 8 Switch LED Controller 7 6 Console PCBs JCM434 CN1M...
Page 27: ...25 Console PCBs JCM434 CN2M...
Page 28: ...26 Keyboard PCB JCM887T KY1M...
Page 29: ...27 Keyboard PCB JCM887T KY2M...
Page 30: ...28 Keyboard PCB JCM887T KY3M...