![Casio CE-235 Service Manual Download Page 3](http://html1.mh-extra.com/html/casio/ce-235/ce-235_service-manual_2568494003.webp)
1
1. FEATURES
The differece between CE-2300 and CE-2350 is as follows;
2. SPECIFICATION
2-1. Electrical specifications
Power consumption :
Specification :
0.35A
In operation
Max.
0.22A
Stanby
Min.
0.09A
Power OFF
0.08A
Memory protection
Back-up battery :
Mangan battery (UM-3 x 3 pcs.)
Back-up period :
1 year (25°C)
Battery life :
Replace the battery every year.
Clock & Calendar
Accuracy :
Within 120 sec. per month (25°C)
Auto calendar :
Effective until 2099 A.D.
2-2. Environmental specifications
Operating temperature :
0°C ~ 40°C
Operating humidity :
10 % ~ 90%
Storage temperature :
-25°C ~ 65°C
Storage humidity :
10% ~ 95%
Vibration strength :
1.5G (The machine must be inthe carton box.)
2-3. Principal components
CPU :
Name :
uPD75516GF-351-3B9
Number of control bit :
4
Internal RAM :
512x 4 bits
Internal ROM :
12160 x 8 bits
Main system clock :
4.19 MHz
Sub system clock :
32.768 Khz
Item
C E - 2 3 0 0
C E - 2 3 5 0
Department number
8
19 x 2
(for using DEPT SHFT key)
PLU number
200
400
Clerk number
4
10
Post-finalization receipt printing
24 lines
52 lines
Total/Change indicators
Mounted
Nil
RAM capacity
8 KBytes
32 KBytes
Summary of Contents for CE-235
Page 1: ...SERVICE MANUAL ELECTRONIC CASH REGISTER CE 2350 EX 259 JAN 1995...
Page 18: ...8 PCB LAYOUT 16...
Page 19: ...17...
Page 20: ...18...
Page 21: ...19...
Page 22: ...20...
Page 23: ...21...
Page 24: ...22...
Page 25: ...23...
Page 26: ...24...
Page 27: ...25...
Page 28: ...26...
Page 29: ...27...
Page 36: ...34 5 Button block 33 26 32 27 35 34 31 29 36 37 28 25 24 44 40 40 2 42 42 41 23 39 38 30 43 22...
Page 39: ...37 7 Upper case block 55 56 54 52 51 50 57 58 53 49...
Page 42: ...40 9 Printer unit...
Page 44: ...42 10 Drawer unit 10 1 DL 2417 for U S A...
Page 46: ...44 10 2 DL 2351 for Canada...