Casio 3144 Operation Manual Download Page 2

Operation Guide 3144

2

To set the time and date

1. In the Timekeeping Mode, hold down 

A

 until the city code starts to flash,

which indicates the setting screen.

2. Use 

D

 and 

B

 to select the city code you want.

Make sure you select your Home City code before changing any other
setting.

For full information on city codes, see the “City Code Table”.

The following steps explain how to configure timekeeping settings only.

4. When the timekeeping setting you want to change is flashing, use 

D

 and/

or 

B

 to change it as described below.

3. Press 

C

 to move the flashing in the sequence shown below to select the

other settings.

Year

Seconds

Hour

Minutes

Day

Month

12/24-Hour
Format

Power
Saving

Barometric 
Pressure Unit

Altitude Unit

Temperature 
Unit

City Code

DST

  Do this:

Use 

D

 (east) and

B

(west).

Press 

D

.

Press 

D

.

  To do this:

Change the city code

Toggle between Daylight Saving
Time (

ON

) and Standard Time

(

OFF

).

Toggle between 12-hour (

12H

)

and 24-hour (

2

4

H

) timekeeping.

Screen

5. Press 

A

 to exit the setting screen.

Note

You also need to enter the Timekeeping Mode in order to configure the
following settings.

Power saving on/off (“To turn Power Saving on and off”)
Temperature, altitude, and barometric pressure units (“To select the
temperature, altitude, and barometric pressure units”)

Press 

D

.

Use 

D

 (+) and 

B

 (–).

Reset the seconds to 

00

Change the hour or minutes

Change the year, month, or day

Daylight Saving Time (DST)

Daylight Saving Time (summer time) advances the time setting by one hour
from Standard Time. Remember that not all countries or even local areas use
Daylight Saving Time.

To change the Daylight Saving Time (summer time) setting

1. In the Timekeeping Mode, hold down 

A

 until

the city code starts to flash, which indicates
the setting screen.

2. Press 

C

 and the DST setting screen appears.

3. Use 

D

 to cycle through the DST settings in

the sequence shown below.

DST off (

OFF

)

DST on (

ON

)

4. When the setting you want is selected, press 

A

 to exit the setting screen.

 The 

DST

 indicator appears to indicate that Daylight Saving Time is turned on.

l l l

l

ll

ll

ll

ll

l

l l

l l l

DST indicator

Barometer/Thermometer

This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.

You can calibrate the pressure sensor and the temperature sensor if you
suspect that readings are incorrect.

To take barometric pressure and temperature readings

Pressing 

B

 in the Timekeeping Mode or

Altimeter Mode enters the Barometer/
Thermometer Mode and starts barometric
pressure and temperature measurements
automatically .

It can take up to four or five seconds for the
barometric pressure reading to appear after
you enter the Barometer/Thermometer Mode.

Barometric pressure is displayed in units of
1hPa (or 0.05 inHg).

Temperature

Barometric
pressure

Barometric
pressure graph

Pressure
differential
pointer

The displayed barometric pressure value changes to 

xxxx

 hPa (or inHg) if

a measured barometric pressure falls outside the range of 260 hPa to
1100 hPa (7.65 inHg to 32.45 inHg). The barometric pressure value will
reappear as soon as the measured barometric pressure is within the
allowable range.

Temperature is displayed in units of 0.1

°

C (or 0.2

°

F).

The displayed temperature value changes to 

xxx

 

°

C (or 

°

F) if a measured

temperature falls outside the range of –10.0

°

C to 60.0

°

C (14.0

°

F to

140.0

°

F). The temperature value will reappear as soon as the measured

temperature is within the allowable range.

In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.

You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius  (

°

C)  or Fahrenheit

(

°

F) as the display unit for the measured temperature value. See “To select

the temperature, altitude, and barometric pressure units”.

See “Barometer and Thermometer Precautions” for important precautions.

Barometric Pressure Graph

Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 24 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.

A rising graph generally means improving weather.

A falling graph generally means deteriorating weather.

Note that if there are sudden changes in barometric
pressure or temperature, the graph line of past
measurements may run off the top or bottom of the display.
The entire graph will become visible once barometric
conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.

Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)

Sensor malfunction

Not visible on
the display.

Barometric Pressure Differential Pointer

This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.

Pressure differential is indicated in the range of 

±

5 hPa, in 1-hPa units.

The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).

Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.

Pressure differential
examples in the
illustration are indicated
in 3 hPa/0.1 inHg steps.

Current pressure less
than most recent
measured pressure

Current pressure greater
than most recent
measured pressure

Barometric pressure
differential

inHg values

hPa values

About Barometric and Temperature Measurements

Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds.

You also can perform a barometric pressure and temperature measurement
at any time by pressing 

B

 in the Barometer/Thermometer Mode.

Summary of Contents for 3144

Page 1: ...se through the use of this watch About This Manual Button operations are indicated using the letters shown in the illustration Each section of this manual provides you with the information you need to perform operations in each mode Further details and technical information can be found in the Reference section Light The actual level at which some functions are disabled depends on the watch model ...

Page 2: ...he temperature value will reappear as soon as the measured temperature is within the allowable range In some areas barometric pressure is expressed in millibars mb instead of hectopascals hPa It really makes no difference because 1hPa 1mb You can select either hectopascals hPa or inchesHg inHg as the display unit for the measured barometric pressure and Celsius C or Fahrenheit F as the display uni...

Page 3: ...urrent altitude 1 Press D in the Timekeeping Mode or Barometer Thermometer Mode to enter the Altimeter Mode The watch will start altitude measurement automatically and display the result It can take up to four or five seconds for the altitude reading to appear after you enter the Altimeter Mode 2 If you want the altitude value and altitude graph to be updated in accordance with the altitude measur...

Page 4: ...altitude within the range of 10 000 to 10 000 meters 32 800 to 32 800 feet Pressing D and B at the same time returns to OFF no reference altitude so the watch performs air pressure to altitude conversions based on preset data only 3 Press A to exit the setting screen l l l l l l l l l l l l l l l l l l l l l Altitude graph The altitude graph shows Altimeter Mode measurement results The vertical ax...

Page 5: ...n Daylight Saving Time and Standard Time if the displayed city code is GMT Note that the DST Standard Time setting affects only the currently displayed city code Other city codes are not affected DST indicator Stopwatch The stopwatch lets you measure elapsed time split times and two finishes The display range of the stopwatch is 23 hours 59 minutes 59 99 seconds The stopwatch continues to run rest...

Page 6: ...n a bicycle or operating a motorcycle or any other motor vehicle Sudden and unintended operation of the auto light switch can create a distraction which can result in a traffic accident and serious personal injury To turn the auto light switch on and off In the Timekeeping Mode hold down L for about three seconds to toggle the auto light switch on A EL displayed and off A EL not displayed The auto...

Page 7: ...nt status of the rechargeable battery s power The flashing LOW indicator at Level 3 tells you that battery power is very low and that exposure to bright light for charging is required as soon as possible At Level 5 all functions are disabled and settings return to their initial factory defaults Once the battery reaches Level 2 after falling to Level 5 reconfigure the current time date and other se...

Page 8: ...the Power Saving on off screen appears 3 Press D to toggle Power Saving on ON and off OFF 4 Press A to exit the setting screen The Power Saving on indicator PS is on the display in all modes while Power Saving is turned on l l l l l l l l l l l l l l l l l l Power Saving on indicator Timekeeping Resetting the seconds to 00 while the current count is in the range of 30 to 59 causes the minutes to b...

Page 9: ... F Barometric Pressure 1 hPa 0 05 inHg Pressing D and B at the same time returns to the factory calibration OFF 4 Press A to return to the Barometer Thermometer Mode screen l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l To select the temperature altitude and barometric pressure units 1 Enter the Timekeeping Mode 2 Hold down A until the city code starts to flash which indic...

Reviews: