Casio 3143 Operation Manual Download Page 6

Operation Guide 3143

6

Altitude graph

The altitude graph shows Altimeter Mode
measurement results.

The vertical axis of the graph represents
altitude, and each dot stands for 10 meters (40
feet).

The horizontal axis represents time, and the flashing dot in the rightmost
column indicates the latest measurement result. For the first three minutes,
each dot represents five seconds. After that, each dot represents two
minutes.

An out of range measurement result or a measurement error will cause the
column of dots for that measurement to be blank (skipped).

Time

Altitude

Altitude Differential

You also can use the Altimeter Mode to measure the altitude differential
from a specific reference altitude. Specifying the point is as simple as
pressing a single button to reset the current reference altitude value to zero.
Altitude differential measurement is performed each time the watch performs
an altitude measurement.

You can perform altitude differential measurement only whenever you select
format number 3 or 4 as the Altimeter Mode display format.

The range of the altitude differential value is –3,000 meters (–9,980 feet) to
3,000 meters (9,980 feet).

-- -- --

” is displayed in place of the altitude differential value whenever the

measured value is outside the allowable range.

The watch will assume that the reference altitude setting is zero for the first
measurement after you exit the Altimeter Mode setting screen.

See “Using Altitude Differential Measurement While Mountain Climbing or
Hiking” for some real-life examples of how to use this feature.

To reset the altitude differential value to zero

In the Altimeter Mode, press 

A

.

This will start altitude measurement. The
altitude differential value will show 

0

 after

measurement is complete.

You must perform altitude differential
measurement whenever you select format
number 3 or 4 as the Altimeter Mode display
format.

Using Altitude Differential Measurement While Mountain
Climbing or Hiking

After you zero reset the reference altitude value at a particular location while
mountain climbing or hiking, you easily can measure the change in the
altitude between that point and another point.

Altitude differential

To use altitude differential measurement

1. In the Altimeter Mode, check to make sure

that the display shows the altitude differential
value.

If the altitude differential value is not
displayed, use the procedure under “To
select an Altimeter Mode display format” to
select display format 3 or 4.

2. Use the contour lines on your map to

determine the difference in altitude between
your current location and your destination.

3. In the Altimeter Mode, press 

A

 to take an

altitude reading.

This causes the altitude differential value to
appear at the top of the display.

Current
location

Destination
altitude

4. While monitoring the difference between the

altitude you found on the map and the altitude
differential value displayed by the watch,
advance towards your destination.

If you determined that the difference between
the map altitude and your current location is
+80 meters, for example, you are approaching
your destination when the displayed altitude
differential value shows +80 meters.

Altitude differential

Altitude

Recalling Altitude Data

You can use the Data Recall Mode to the view periodic records and current
session record that are in watch memory. Altitude data records are created
and stored in the Altimeter Mode.

Data Screens

The following explains the contents of each of the screens that appear in the
Data Recall Mode.

Note

While the periodic record, high altitude, or low altitude screen is displayed,
the bottom part of the display alternates between the measurement date
(month and day) and measurement time, at 1-second intervals.

Altitude

Measurement date
(Month – Day)

Alternates at

1-second intervals.

Measurement time
(Hour : Minute)

Periodic
record
indicator

Periodic Records

Periodic records show only data for the last save session performed with the
watch. There can be up to 40 periodic records in memory.

Current Session Record Contents

The following data items show the contents of the current session record.

Data Type

High Altitude

Low Altitude

Total Ascent

Total Descent

Description

Highest altitude reached during the
recalled session.
Lowest altitude reached during the recalled
session.
Total cumulative ascent during the recalled
session.
Total cumulative descent during the
recalled session.

Screen Name

MAX

MIN

ASC

DSC

REC

(40)

REC

(2)

REC

(1)

MAX

MIN

ASC

DSC

To view periodic records and current session record contents

1. Enter the Data Recall Mode.
2. Use 

D

 and 

B

 to scroll through the data and display the one you want.

To view the current session record contents, use 

D

 to scroll forward

past the last periodic record (which will display the current session
record 

MAX

 screen), or 

B

 to scroll back past the first periodic record

(to the 

DSC

 screen).

3. After you are finished viewing data, press 

C

 to exit the Data Recall Mode.

Dashes (

xxxx

) will be displayed if there is no corresponding data due to

error, etc. In such cases, total ascent (

ASC

) and total descent (

DSC

)

values will show zero.

Periodic

records

D

B

Current session

record

When the total ascent (

ASC

) or total descent (

DSC

) exceeds 99,995

meters (or 99,980 feet), the applicable value will restart from zero.

World Time

World Time displays the current time in 30 cities
(29 time zones) around the world.

If the current time shown for a city is wrong,
check your Home City time settings and make
the necessary changes.

For full information on city codes, see the “City
Code Table”.

All of the operations in this section are
performed in the World Time Mode, which you
enter by pressing 

C

.

To view the time in another city

In the World Time Mode, use 

D

 (east) and 

B

(west) to scroll through city codes (time zones).

When the currently selected time zone is one
that includes mostly ocean, a value indicating
the zone’s Greenwich Mean Time differential
appears in place of a city code.

Timekeeping
Mode time

Current time in the zone
of the selected city code

City code

To toggle a city code time between Standard Time and Daylight
Saving Time

1. In the World Time Mode, use 

D

 (east) and 

B

(west) to display the city code (time zone)
whose Standard Time/Daylight Saving Time
setting you want to change.

2. Hold down 

A

 to toggle between Daylight

Saving Time (

DST

 indicator displayed) and

Standard Time (

DST

 indicator not displayed).

The 

DST

 indicator appears on the display

whenever you display a city code for which
Daylight Saving Time is turned on.

You cannot toggle between Daylight Saving Time and Standard Time if the
displayed city code is 

GMT

.

Note that the DST/Standard Time setting affects only the currently
displayed city code. Other city codes are not affected.

DST indicator

Summary of Contents for 3143

Page 1: ...aking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only CASIO COMPUTER CO LTD assumes no responsibility for any loss or any claims by third parties that may arise through the use of this watch Applications The built in sensors of this watch measure barometric pressure temperature and altitude Measure...

Page 2: ...ot perform any button operations or move the watch during this time Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone The time calibration signal the watch will attempt to pick up depends on its current Home City code se...

Page 3: ...no reception has been successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down A until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press D to toggle auto receive on ON and off ...

Page 4: ...r current altitude based on the value you specify Altimeter functions also include storage of measurement data in memory You also can measure the altitude differential change from a specific reference altitude Specifying the reference altitude is as simple as pressing a single button to reset the reference altitude to zero Important This watch estimates altitude based on air pressure This means th...

Page 5: ...tored You can recall saved records using the Data Recall Mode Periodic Records Periodic records of up to 40 altitude readings are taken during a save session You can use the Data Recall Mode to view these records How periodic records are created and saved The following operation is performed simultaneously with the operation described under How current session record data is updated a The watch cr...

Page 6: ...he view periodic records and current session record that are in watch memory Altitude data records are created and stored in the Altimeter Mode Data Screens The following explains the contents of each of the screens that appear in the Data Recall Mode Note While the periodic record high altitude or low altitude screen is displayed the bottom part of the display alternates between the measurement d...

Page 7: ...ations in this section are performed in the Alarm Mode which you enter by pressing C Alarm time Hour Minutes Alarm number Current time To set an alarm time 1 In the Alarm Mode use D and B to scroll through the alarm screens until the one whose time you want to set is displayed 2 Hold down A until the hour setting of the alarm time start to flash which indicates the setting screen This automaticall...

Page 8: ...wrist in order to eliminate the effects of body heat In the case of altitude measurement on the other hand it is better to leave the watch on your wrist because doing so keeps the watch at a constant temperature which contributes to more accurate altitude measurements To give altitude measurement priority leave the watch on your wrist or in any other location where the temperature of the watch is ...

Page 9: ...udy Day 5 000 lux Indoor Fluorescent Lighting 500 lux Timekeeping Use the Timekeeping Mode to set and view the current time and date Pressing A while in the Timekeeping Mode will cycle through the Timekeeping Mode display formats as shown below Day of week Day Day of the Week Day Screen PM indicator Hour Minute Second Year Month Day Date Screen Barometric Pressure Graph Screen Day Barometric press...

Page 10: ... tone on not displayed and off displayed Since the C button is also the mode change button holding it down to turn the button operation on or off also causes the watch s current mode to change The mute indicator is displayed in all modes when the button operation tone is turned off Power Saving When turned on Power Saving enters a sleep state automatically whenever the watch is left for a certain ...

Page 11: ... back towards your face again If this does not work drop your arm all the way down so it hangs at your side and then bring it back up again Under certain conditions illumination does not turn on until about one second after you turn the face of the watch towards you This does not necessarily indicate malfunction You may notice a very faint clicking sound coming from the watch when it is shaken bac...

Page 12: ...AR BER Athens Cairo Jerusalem Jeddah Tehran Dubai Kabul Karachi Delhi Dhaka Yangon Bangkok Hong Kong Seoul Tokyo Adelaide Sydney Noumea Wellington 02 0 03 0 03 5 04 0 04 5 05 0 05 5 06 0 06 5 07 0 08 0 09 0 09 5 10 0 11 0 12 0 Helsinki Istanbul Beirut Damascus Cape Town Kuwait Riyadh Aden Addis Ababa Nairobi Moscow Shiraz Abu Dhabi Muscat Male Mumbai Kolkata Colombo Jakarta Phnom Penh Hanoi Vienti...

Reviews: