Casio 3143 Operation Manual Download Page 3

Operation Guide 3143

3

The watch takes from two to 14 minutes to receive the time calibration
signal whenever a calibration time is reached. Do not perform any button
operation within 14 minutes before or after any one of the calibration times.
Doing so can interfere with correct calibration.

Remember that reception of the calibration signal depends on the current
time in the Timekeeping Mode. The receive operation will be performed
whenever the display shows any one of the calibration times, regardless of
whether or not the displayed time actually is the correct time.

About the Receiving Indicator

The receiving indicator shows the strength of the calibration signal being
received. For best reception, be sure to keep the watch in a location where
signal strength is strongest. The receiving indicator is displayed while an auto
or manual receive operation is in progress.

Even in an area where signal strength is strong, it takes about 10 seconds
for signal reception to stabilize enough for the receiving indicator to indicate
signal strength.

Receiving
indicator

Weak

(Level 1)

Strong

(Level 5)

l ll

lll

ll

ll

l l

Use the receiving indicator as a guide for checking signal strength and for
finding the best location for the watch during signal receive operations.

Following reception of the time calibration signal and calibration of the
watch’s time setting, the Level 5 receiving indicator will remain on the
display in all modes. The Level 5 receiving indicator will not be displayed if
signal reception was unsuccessful or after you adjust the current time
setting manually.

The Level 5 receiving indicator is displayed only when the watch is able to
receive both time and date data successfully. It does not appear when only
time data is received.

The Level 5 receiving indicator indicates that at least one of the auto
calibration signal receive operations was successful. Note, however, that
the indicator disappears from the display each day at the start of the first
auto receive operation of the day.

To perform manual receive

1. Enter the Receive Mode.
2. Place the watch on a stable surface so its 12

o’clock side is facing towards a window.

3. Hold down 

D

 for about two seconds until 

RC

starts to flash on the display.

Time calibration signal reception takes from
two to seven minutes, but in some cases it can
take as long as 14 minutes.Take care that you
do not perform any button operations or move
the watch during this time.

If the receive operation is successful, the
reception date and time appear on the display,
along with the 

GET

 indicator.

The watch will enter the Receive Mode if you
press 

D

 or if you do not perform any button

operation for about one or two minutes.

l l l

l

l

l

lll

ll

ll

l

l l

l

llll

llll

ll

ll

Receiving

Receive successful

If the current reception fails but a previous
reception was successful, the display shows
the previous reception’s date and time, and the

ERR

 indicator.  

 indicates that none of

the reception operations have been successful
during the current date.
The watch will enter the Receive Mode without
changing the time setting if you press 

D

 or if

you do not perform any button operation for
about one or two minutes.

Note

To interrupt a receive operation and return to
the Receive Mode, press 

D

.

Receive failed

If there was a previously
successful reception

If no reception has
been successful

To turn auto receive on and off

1. Enter the Receive Mode.
2. In the Receive Mode, hold down 

A

 until the

current auto receive setting (

ON

 or 

OFF

)

starts to flash. This is the setting screen.

Note that the setting screen will not appear
if the currently selected Home City is one
that does not support time calibration
reception.

3. Press 

D

 to toggle auto receive on (

ON

) and

off (

OFF

).

4. Press 

A

 to exit the setting screen.

For information about city codes that support
signal receive, see “To specify your Home City”.

l l l

ll

ll

ll

ll

ll

ll

l l l

l

On/Off
status

To check the latest signal reception results

Enter the Receive Mode.

When receive is successful, the display shows
the time and date that receive was successful.

 indicates that none of the reception

operations were successful.

To return to the Timekeeping Mode, press 

C

.

The watch is not in the Receive
Mode.

Your current Home City is one
that does not support signal
reception.

You changed the time setting
manually.

You changed the DST setting of
your Home City in the World
Time Mode.

You pressed a button while
signal receive was in progress.

Even if receive is successful,
the Level 5 receiving indicator
disappears from the display
each day when the first auto
receive operation of the day is
performed.

Time data (hour, minute,
second) only was received
during the last receive
operation. The Level 5 receiving
indicator appears only when
time data and date data (year,
month, day) are both received.

Cannot perform
manual receive.

Auto receive is
turned on, but
the Level 5
receiving
indicator does
not appear on
the display.

Enter the Receive Mode
and try again.

Select one of the
following as your Home
City: 

LON

PAR

BER

,

ATH

HKG

SEL

TYO

,

HNL

ANC

LAX

DEN

,

CHI

, or 

NYC

.

Perform manual signal
receive or wait until the
next auto signal receive
operation is performed.

Check to make sure the
watch is in a location
where it can receive the
signal.

What you should do

Problem

Probable Cause

Signal Reception Troubleshooting

Check the following points whenever you experience problems with signal
reception.

If the time is one hour off, the
DST setting may be incorrect.

The Home City code setting is
not correct for the area where
you are using the watch.

Change the DST setting
to Auto DST.

Select the correct Home
City code.

Time setting is
incorrect
following signal
reception.

For further information, see “Important!” under “Time Calibration Signal
Reception” and “Radio-controlled Atomic Timekeeping Precautions”.

Barometer/Thermometer

This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.

You can calibrate the pressure sensor and the temperature sensor if you
suspect that readings are incorrect.

To take barometric pressure and temperature readings

Pressing 

B

 in the Timekeeping Mode or

Altimeter Mode enters the Barometer/
Thermometer Mode and starts barometric
pressure and temperature measurements
automatically .

It can take up to four or five seconds for the
barometric pressure reading to appear after
you enter the Barometer/Thermometer Mode.

Barometric pressure is displayed in units of
1hPa (or 0.05 inHg).

The displayed barometric pressure value
changes to 

xxxx

 hPa (or inHg) if a measured

barometric pressure falls outside the range of
260 hPa to

1100 hPa (7.65 inHg to 32.45

inHg). The barometric pressure value will
reappear as soon as the measured barometric
pressure is within the allowable range.

Temperature

Barometric
pressure

Barometric
pressure graph

Pressure
differential
pointer

Summary of Contents for 3143

Page 1: ...aking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only CASIO COMPUTER CO LTD assumes no responsibility for any loss or any claims by third parties that may arise through the use of this watch Applications The built in sensors of this watch measure barometric pressure temperature and altitude Measure...

Page 2: ...ot perform any button operations or move the watch during this time Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone The time calibration signal the watch will attempt to pick up depends on its current Home City code se...

Page 3: ...no reception has been successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down A until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press D to toggle auto receive on ON and off ...

Page 4: ...r current altitude based on the value you specify Altimeter functions also include storage of measurement data in memory You also can measure the altitude differential change from a specific reference altitude Specifying the reference altitude is as simple as pressing a single button to reset the reference altitude to zero Important This watch estimates altitude based on air pressure This means th...

Page 5: ...tored You can recall saved records using the Data Recall Mode Periodic Records Periodic records of up to 40 altitude readings are taken during a save session You can use the Data Recall Mode to view these records How periodic records are created and saved The following operation is performed simultaneously with the operation described under How current session record data is updated a The watch cr...

Page 6: ...he view periodic records and current session record that are in watch memory Altitude data records are created and stored in the Altimeter Mode Data Screens The following explains the contents of each of the screens that appear in the Data Recall Mode Note While the periodic record high altitude or low altitude screen is displayed the bottom part of the display alternates between the measurement d...

Page 7: ...ations in this section are performed in the Alarm Mode which you enter by pressing C Alarm time Hour Minutes Alarm number Current time To set an alarm time 1 In the Alarm Mode use D and B to scroll through the alarm screens until the one whose time you want to set is displayed 2 Hold down A until the hour setting of the alarm time start to flash which indicates the setting screen This automaticall...

Page 8: ...wrist in order to eliminate the effects of body heat In the case of altitude measurement on the other hand it is better to leave the watch on your wrist because doing so keeps the watch at a constant temperature which contributes to more accurate altitude measurements To give altitude measurement priority leave the watch on your wrist or in any other location where the temperature of the watch is ...

Page 9: ...udy Day 5 000 lux Indoor Fluorescent Lighting 500 lux Timekeeping Use the Timekeeping Mode to set and view the current time and date Pressing A while in the Timekeeping Mode will cycle through the Timekeeping Mode display formats as shown below Day of week Day Day of the Week Day Screen PM indicator Hour Minute Second Year Month Day Date Screen Barometric Pressure Graph Screen Day Barometric press...

Page 10: ... tone on not displayed and off displayed Since the C button is also the mode change button holding it down to turn the button operation on or off also causes the watch s current mode to change The mute indicator is displayed in all modes when the button operation tone is turned off Power Saving When turned on Power Saving enters a sleep state automatically whenever the watch is left for a certain ...

Page 11: ... back towards your face again If this does not work drop your arm all the way down so it hangs at your side and then bring it back up again Under certain conditions illumination does not turn on until about one second after you turn the face of the watch towards you This does not necessarily indicate malfunction You may notice a very faint clicking sound coming from the watch when it is shaken bac...

Page 12: ...AR BER Athens Cairo Jerusalem Jeddah Tehran Dubai Kabul Karachi Delhi Dhaka Yangon Bangkok Hong Kong Seoul Tokyo Adelaide Sydney Noumea Wellington 02 0 03 0 03 5 04 0 04 5 05 0 05 5 06 0 06 5 07 0 08 0 09 0 09 5 10 0 11 0 12 0 Helsinki Istanbul Beirut Damascus Cape Town Kuwait Riyadh Aden Addis Ababa Nairobi Moscow Shiraz Abu Dhabi Muscat Male Mumbai Kolkata Colombo Jakarta Phnom Penh Hanoi Vienti...

Reviews: