Casio 3134 Operation Manual Download Page 11

Operation Guide 3134 3205

11

0 ft

2000 ft

4000 ft

6000 ft

8000 ft

10000 ft

12000 ft

14000 ft

25.84 inHg

22.23 inHg

19.03 inHg

44.7

°

F

30.5

°

F

16.2

°

F

59.0

°

F

29.92 inHg

About 3.6

°

per 1000 ft

About 0.15 inHg per 200 ft

About 0.17 inHg per 200 ft

About 0.192 inHg per 200 ft

About 0.21 inHg per 200 ft

Source:   International Civil Aviation Organization

Note that the following conditions will prevent you from obtaining accurate
altitude readings:

When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact

There are two standard methods of expressing altitude: Absolute altitude and
relative altitude. Absolute altitude expresses an absolute height above sea
level. Relative altitude expresses the difference between the height of two
different places.

Height of building 130 m
(relative altitude)

Rooftop at an altitude of
230 m above sea level
(absolute altitude)

Sea Level

Precautions Concerning Simultaneous Measurement of Altitude and
Temperature

Though you can perform altitude and temperature measurements at the same
time, you should remember that each of these measurements requires
different conditions for best results. With temperature measurement, it is best
to remove the watch from your wrist in order to eliminate the effects of body
heat. In the case of altitude measurement, on the other hand, it is better to
leave the watch on your wrist, because doing so keeps the watch at a
constant temperature, which contributes to more accurate altitude
measurements.

To give altitude measurement priority, leave the watch on your wrist or in
any other location where the temperature of the watch is kept constant.

To give temperature measurement priority, remove the watch from your
wrist and allow it to hang freely from your bag or in another location where
it is not exposed to direct sunlight. Note that removing the watch from your
wrist can affect pressure sensor readings momentarily.

Power Supply

This watch is equipped with a solar cell and a special rechargeable battery
(secondary battery) that is charged by the electrical power produced by the
solar cell. The illustration shown below shows how you should position the
watch for charging.

Example:

Orient the watch so its face is
pointing at a light source.

The illustration shows how to position a
watch with a resin band.

Note that charging efficiency drops when
any part of the solar cell is blocked by
clothing, etc.

You should try to keep the watch outside
of your sleeve as much as possible.
Charging is reduced significantly if the
face is covered only partially.

Solar cell

Important!

Storing the watch for long periods in an area where there is no light or
wearing it in such a way that it is blocked from exposure to light can cause
rechargeable battery power to run down. Be sure that the watch is exposed
to bright light whenever possible.

This watch uses a special rechargeable battery to store power produced by
the solar cell, so regular battery replacement is not required. However, after
very long use, the rechargeable battery may lose its ability to achieve a full
charge. If you experience problems getting the special rechargeable battery
to charge fully, contact your dealer or CASIO distributor about having it
replaced.

Never try to remove or replace the watch’s special battery yourself. Use of
the wrong type of battery can damage the watch.

All data stored in memory is deleted, and the current time and all other
settings return to their initial factory defaults whenever battery power drops
to Level 5 and when you have the battery replaced.

Turn on the watch’s Power Saving function and keep it in an area normally
exposed to bright light when storing it for long periods. This helps to keep
the rechargeable battery from going dead.

Battery Power Indicators

The battery power indicator on the display shows you the current status of the
rechargeable battery’s power.

Battery power
indicator

Level

1

2

3

4

5

Battery Power

Indicator

(Charge Soon Alert)

(Charge Soon Alert)

Function Status

All functions enabled.

All functions enabled.

Auto and manual receive,
illumination, beeper, and
sensor operation disabled.

Except for timekeeping and
the 

C

 (charge) indicator, all

functions and display
indicators disabled.

All functions disabled.

l l l l l l l

ll

ll

ll

ll

ll

ll

l l

l

l l ll

l

l

ll

ll

ll

ll

l

ll

l l

l l ll

l

l

ll

ll

ll

ll

l

ll

l l

The flashing 

LOW

 indicator at Level 3 tells you that battery power is very

low, and that exposure to bright light for charging is required as soon as
possible.

At Level 5, all functions are disabled and settings return to their initial
factory defaults. Once the battery reaches Level 2 (indicated by 

indicator)

after falling to Level 5, reconfigure the current time, date, and other
settings.

Display indicators reappear as soon as the battery is charged from Level 5
to Level 2.

Leaving the watch exposed to direct sunlight or some other very strong light
source can cause the battery power indicator to show a reading temporarily
that is higher than the actual battery level. The correct battery level should
be indicated after a few minutes.

Performing multiple sensor, illumination, or
beeper operations during a short period may
cause all of the battery indicators (

L, M, H

) to

flash on the display. Illumination, alarm,
countdown timer alarm, hourly time signal, and
sensor operations will be disabled until battery
power recovers.
After some time, battery power will recover and
battery indicators (

L, M, H

) will disappear,

indicating that the above functions are enabled
again.

Even if battery power is at Level 1 or Level 2, the Digital Compass Mode,
Barometer/Thermometer Mode, or Altimeter Mode sensor may be disabled
if there is not enough voltage available to power it sufficiently. This is
indicated by battery indicators (

L, M, H

) on the display.

If battery indicators (

L, M, H

) appears frequently, it probably means that

remaining battery power is low. Leave the watch in bright light to allow it to
charge.

l l l

l

ll

ll

ll

l

l l l

Charging Precautions

Certain charging conditions can cause the watch to become very hot. Avoid
leaving the watch in the areas described below whenever charging its
rechargeable battery. Also note that allowing the watch to become very hot
can cause its liquid crystal display to black out. The appearance of the LCD
should become normal again when the watch returns to a lower temperature.

Warning!
Leaving the watch in bright light to charge its rechargeable battery can
cause it to become quite hot. Take care when handling the watch to
avoid burn injury. The watch can become particularly hot when exposed
to the following conditions for long periods.

On the dashboard of a car parked in direct sunlight

Too close to an incandescent lamp

Under direct sunlight

Charging Guide

After a full charge, timekeeping remains enabled for up to about five months.

The following table shows the amount of time the watch needs to be
exposed to light each day in order to generate enough power for normal
daily operations.

For details about the battery operating time and daily operating conditions,
see the “Power Supply” section of the Specifications.

Stable operation is promoted by frequent exposure to light.

Exposure Level (Brightness)

Outdoor Sunlight (50,000 lux)

Sunlight Through a Window (10,000 lux)

Daylight Through a Window on a Cloudy Day (5,000 lux)

Indoor Fluorescent Lighting (500 lux)

Approximate

Exposure Time

5 minutes

24 minutes

48 minutes

8 hours

Summary of Contents for 3134

Page 1: ... Module 3134 Module 3205 General Guide The illustration below shows which buttons you need to press to navigate between modes In any mode press L to illuminate the display You can use buttons A B and C to enter a sensor mode directly from the Timekeeping Mode or from another sensor mode To enter a sensor mode from the Tide Moon Data Countdown Timer Stopwatch World Time Alarm Data Recall or Receive...

Page 2: ...ls about turning on auto receive for these city codes see To turn auto receive on and off You can disable time signal reception if you want See To turn auto receive on and off for more information Time Calibration Signal Reception There are two different methods you can use to receive the time calibration signal auto receive and manual receive Auto Receive With auto receive the watch receives the ...

Page 3: ...rm any button operation for about one or two minutes l l l l l l l l l l lll Receiving Receive successful If the current reception fails but a previous reception was successful the display shows the previous reception s date and time and the ERR indicator indicates that none of the reception operations have been successful during the current date The watch will enter the Receive Mode without chang...

Page 4: ...ecomes magnetized Because of this you should be sure to store the watch away from magnets or any other sources of strong magnetism including permanent magnets magnetic necklaces etc and household appliances TVs personal computers washing machines freezers etc Whenever you suspect that the watch may have become magnetized perform one of the calibration procedures under Calibrating the Bearing Senso...

Page 5: ...at you are doing is aligning north on the map with north as indicated by the watch To find the bearing to an objective To determine the direction angle to an objective on a map and head in that direction To set a map and find your current location 1 With the watch on your wrist position it so the face is horizontal 2 In the Timekeeping Digital Compass Barometer Thermometer or Altimeter Mode press ...

Page 6: ...ns are performed as soon as you enter the Barometer Thermometer Mode After that barometric pressure and temperature measurements are taken every five seconds You also can perform a barometric pressure and temperature measurement at any time by pressing B in the Barometer Thermometer Mode Altimeter The watch s altimeter uses a pressure sensor to detect current air pressure which is then used to est...

Page 7: ...e altitude whenever one is available during your climb To set a reference altitude 1 In the Altimeter Mode hold down E for about two seconds until either OFF or the current reference altitude value starts to flash This is the setting screen 2 Press A or C to change the current reference altitude value by 5 meters or 20 feet You can set the reference altitude within the range of 10 000 to 10 000 me...

Page 8: ...e time Reversing the Displayed Moon Phase The left right east west appearance of the Moon depends on whether the Moon is north of you northerly view or south of you southerly view as you view it You can use the procedure below to reverse the displayed Moon phase so it matches the actual appearance of the Moon where you are located To determine the viewing direction of the Moon use a compass to tak...

Page 9: ...me A C C A C Start Split Split release Stop Clear Two Finishes A C A C C Start Split Stop Split release Clear Display time of second runner Second runner finishes SPL displayed To measure times with the stopwatch World Time World Time displays the current time in 33 cities 29 time zones around the world If the current time shown for a city is wrong check your Home City time settings and make the n...

Page 10: ...out three seconds to toggle the auto light switch on A EL displayed and off A EL not displayed The auto light switch on indicator A EL is on the display in all modes while the auto light switch is turned on The auto light switch turns off automatically whenever battery power drops to Level 4 Illumination may not turn on right away if you raise the watch to your face while a barometric pressure or ...

Page 11: ...ing function and keep it in an area normally exposed to bright light when storing it for long periods This helps to keep the rechargeable battery from going dead Battery Power Indicators The battery power indicator on the display shows you the current status of the rechargeable battery s power Battery power indicator Level 1 2 3 4 5 Battery Power Indicator Charge Soon Alert Charge Soon Alert Funct...

Page 12: ...metric pressure and altitude units To select the temperature barometric pressure and altitude units Daylight Saving Time DST Daylight Saving Time summer time advances the time setting by one hour from Standard Time Remember that not all countries or even local areas use Daylight Saving Time The time calibration signals transmitted from Mainflingen Germany Anthorn England or Fort Collins the United...

Page 13: ...setting screen automatically Initial Screens When you enter the World Time or Alarm Mode the data you were viewing when you last exited the mode appears first Scrolling The A and C buttons are used on the setting screen to scroll through data on the display In most cases holding down these buttons during a scroll operation scrolls through the data at high speed Sensor Malfunction Indicator Subject...

Page 14: ...hat provides illumination loses power after very long use Illumination may be hard to see when viewed under direct sunlight Illumination turns off automatically whenever an alarm sounds The watch may emit an audible sound whenever the display is illuminated This is due to vibration of the EL panel used for illumination and does not indicate malfunction Frequent use of illumination runs down the ba...

Page 15: ... to date along with the date month day of the reading Other Reference altitude setting Altitude graph Bearing Sensor Precision Direction Within 10 Values are guaranteed for a temperature range of 10 C to 40 C 14 F to 104 F North pointer Within 2 digital segments Pressure Sensor Precision Values are guaranteed for a temperature range of 10 C to 40 C 14 F to 104 F Precision is lessened by strong imp...

Reviews: