Casio 3043 Operation Manual Download Page 10

Operation Guide 3043

10

Question: How does the altimeter work?

Answer: Generally, air pressure and temperature decrease as altitude

increases. This watch bases its altitude measurements on
International Standard Atmosphere (ISA) values stipulated by the
International Civil Aviation Organization (ICAO). These values define
relationships between altitude, air pressure, and temperature.

0 m

500 m

1000 m

1500 m

2000 m

2500 m

3000 m

3500 m

4000 m

899 hPa

795 hPa

701 hPa

616 hPa

8.5

°

C

2

°

C

–4.5

°

C

–11

°

C

15

°

C

1013 hPa

About 6.5

°

per 1000 m

About 8 hPa per 100 m

About 9 hPa per 100 m

About 10 hPa per 100 m

About 11 hPa per 100 m

About 12 hPa per 100 m

Altitude

Air Pressure

Temperature

0 ft

2000 ft

4000 ft

6000 ft

8000 ft

10000 ft

12000 ft

14000 ft

25.84 inHg

22.23 inHg

19.03 inHg

44.7

°

F

30.5

°

F

16.2

°

F

59.0

°

F

29.92 inHg

About 3.6

°

per 1000 ft

About 0.15 inHg per 200 ft

About 0.17 inHg per 200 ft

About 0.192 inHg per 200 ft

About 0.21 inHg per 200 ft

Source:   International Civil Aviation Organization

Note that the following conditions will prevent you from obtaining accurate
readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact

There are two standard methods of expressing altitude: Absolute altitude and
relative altitude. Absolute altitude expresses an absolute height above sea
level. Relative altitude expresses the difference between the height of two
different places.

Height of building 130 m
(relative altitude)

Rooftop at an altitude of
230 m above sea level
(absolute altitude)

Sea Level

Precautions Concerning Simultaneous Measurement of Altitude and
Temperature

Though you can perform altitude and temperature measurements at the same
time, you should remember that each of these measurements requires
different conditions for best results. With temperature measurement, it is best
to remove the watch from your wrist in order to eliminate the effects of body
heat. In the case of altitude measurement, on the other hand, it is better to
leave the watch on your wrist, because doing so keeps the watch at a
constant temperature, which contributes to more accurate altitude
measurements.
The following describes what you should do to give priority to either altitude or
temperature.

To give altitude measurement priority, leave the watch on your wrist or in
any other location where the temperature of the watch is kept constant.

To give temperature measurement priority, remove the watch from your
wrist and allow it to hang freely from your bag or in another location where
it is not exposed to direct sunlight. Note that removing the watch from your
wrist can momentarily affect pressure sensor readings.

Power Supply

This watch is equipped with a solar cell and a special rechargeable battery
(secondary battery) that is charged by the electrical power produced by the
solar cell. The illustration shown below shows how you should position the
watch for charging.

Example:

Orient the watch so its face is
pointing at a light source.

The illustration shows how to position a
watch with a resin band.

Note that charging efficiency drops when
any part of the solar cell is blocked by
clothing, etc.

You should try to keep the watch outside
of your sleeve as much as possible.
Charging is reduced significantly if the
face is only partially covered.

Solar cell

Important!

Storing the watch for long periods in an area where there is no light or
wearing it in such a way that it is blocked from exposure to light can cause
rechargeable battery power to run down. Be sure that the watch is exposed
to bright light whenever possible.

This watch uses a special rechargeable battery to store power produced by
the solar cell, so regular battery replacement is not required. However, after
very long use, the rechargeable battery may lose its ability to achieve a full
charge. If you experience problems getting the special rechargeable battery
to charge fully, contact your dealer or CASIO distributor about having it
replaced.

Never try to remove or replace the watch’s special battery yourself. Use of
the wrong type of battery can damage the watch.

All data stored in memory is deleted, and the current time and all other
settings return to their initial factory defaults whenever battery power drops
to Level 5 and when you have the battery replaced.

Turn on the watch’s Power Saving function and keep it in an area normally
exposed to bright light when storing it for long periods. This helps to keep
the rechargeable battery from going dead.

Battery Power Indicator and Recover Indicator

The battery power indicator on the display shows you the current status of the
rechargeable battery’s power.

Battery power
indicator

Level

1

2

3

4

5

Battery Power

Indicator

(Charge Soon Alert)

Function Status

All functions enabled.

All functions enabled.

Auto and manual receive,
illumination, beeper, and
sensor operation disabled.

Except for timekeeping and
the 

 indicator, all

functions and display
indicators are disabled.

All functions disabled.

ll

l

ll

l

l l l l

ll

l l l l l l l

ll

ll

ll

ll

ll

ll

l l

l

l l l l l l lll

lll

llll

lll

lll

ll

ll

ll l

The flashing 

LOW

 indicator at Level 3 tells you that battery power is very

low, and that exposure to bright light for charging is required as soon as
possible.

At Level 5, all functions are disabled and settings return to their initial
factory defaults. Once the battery reaches Level 2 (indicated by 

indicator)

after falling to Level 4, reconfigure the current time, date, and other
settings.

Display indicators reappear as soon as the battery is charged from Level 5
to Level 2.

Leaving the watch exposed to direct sunlight or some other very strong light
source can cause the battery power indicator to show a reading temporarily
that is higher than the actual battery level. The correct battery level should
be indicated after a few minutes.

Performing multiple sensor, illumination, or
beeper operations during a short period may
cause 

RECOV

 to appear on the display.

Illumination, alarm, countdown timer alarm,
hourly time signal, and sensor operations will
be disabled until battery power recovers.
After some time, battery power will recover and

RECOV

 will disappear, indicating that the

above functions are enabled again.

Even if battery power is at Level 1 or Level 2, the Digital Compass Mode,
Barometer/Thermometer Mode, or Altimeter Mode sensor may be disabled
if there is not enough voltage available to power it sufficiently. This is
indicated by 

RECOV

 on the display.

If 

RECOV

 appears frequently, it probably means that remaining battery

power is low. Leave the watch in bright light to allow it to charge.

Recover indicator

Question: How does the barometer work?

Answer: Barometric pressure indicates changes in the atmosphere, and by

monitoring these changes you can predict the weather with
reasonable accuracy. Rising atmospheric pressure indicates good
weather, while falling pressure indicates deteriorating weather
conditions.
The barometric pressures that you see in the newspaper and on the
TV weather report are measurements corrected to values measured
at 0 m sea level.

Summary of Contents for 3043

Page 1: ... more information Warning The measurement functions built into this watch are not intended for taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure t...

Page 2: ...nal reception can be difficult or even impossible under the conditions listed below Inside or among buildings Inside a vehicle Near a construction site airport or other sources of electrical noise Near high tension power lines Among or behind mountains Near household appliances office equipment or a mobile phone Signal reception normally is better at night than during the day Time calibration sign...

Page 3: ...viously successful reception If no reception was successful To turn auto receive on and off 1 Enter the Receive Mode 2 In the Receive Mode hold down E until the current auto receive setting ON or OFF starts to flash This is the setting screen Note that the setting screen will not appear if the currently selected Home City is one that does not support time calibration reception 3 Press C to toggle ...

Page 4: ...Pa 7 65 inHg to 32 45 inHg The barometric pressure value will reappear as soon as the measured barometric pressure is within the allowable range Temperature is displayed in units of 0 1 C or 0 2 F The displayed temperature value changes to xxx C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will reappear as soon as the measured t...

Page 5: ...y the watch will be more accurate than they would without a reference altitude 400 B A Displaying Your Current Altitude You can use the procedure described in this section to display your current altitude If you leave the watch in the Altimeter Mode it will update the displayed altitude value regularly and indicate reading to reading changes in the altitude graph at the top of the display Importan...

Page 6: ...own C for about one second until REC disappears from the screen You can recall saved records using the Data Recall Mode Other Altimeter Mode Features This section explains other features and settings that are available in the Altimeter Mode Note that all of the information in this section applies to all types of Altimeter Mode measurements unless specifically indicated otherwise Specifying a Refer...

Page 7: ...rds show only data for the last save session performed with the watch There can be up to 40 periodic records in memory Historical Record The historical record shows data for all save sessions performed since the last time the historical record was cleared To view periodic records and current session record contents 1 Enter the Data Recall Mode 2 Use C and A to scroll through the data and display t...

Page 8: ...an set a countdown start time in the range of one minute to 60 minutes in one minute increments Auto repeat Whenever zero is reached the watch beeps and auto repeat automatically restarts the countdown from the countdown start time you set When the countdown reaches zero while auto repeat is turned off the watch will beep and then display the countdown start time without restarting the countdown A...

Page 9: ...the auto light switch on A EL displayed and off A EL not displayed The auto light switch on indicator A EL is on the display in all modes while the auto light switch is turned on The auto light switch turns off automatically whenever battery power drops to Level 4 Illumination may not turn on right away if you raise the watch to your face while a barometric pressure or altitude measurement operati...

Page 10: ...way that it is blocked from exposure to light can cause rechargeable battery power to run down Be sure that the watch is exposed to bright light whenever possible This watch uses a special rechargeable battery to store power produced by the solar cell so regular battery replacement is not required However after very long use the rechargeable battery may lose its ability to achieve a full charge If...

Page 11: ...code For more information see Daylight Saving Time DST below You also need to enter the Timekeeping Mode in order to configure the following settings Display illumination duration To specify the illumination duration Power saving on off To turn Power Saving on and off Temperature barometric pressure and altitude units To select the temperature barometric pressure and altitude units Daylight Saving...

Page 12: ...e Timekeeping Mode hold down E until the city code starts to flash which indicates the setting screen 2 Press D nine times until the Power Saving on off screen appears 3 Press C to toggle Power Saving on ON and off OFF 4 Press E to exit the setting screen The Power Saving on indicator PS is on the display in all modes while Power Saving is turned on l l l l l l l l l l l l l l l l l Power Saving o...

Page 13: ...ntrations of metal metal doors lockers etc high tension wires aerial wires household appliances TVs personal computers washing machines freezers etc Accurate direction readings are impossible while in a train boat air plane etc Accurate readings are also impossible indoors especially inside ferro concrete structures This is because the metal framework of such structures picks up magnetism from app...

Page 14: ...OFF or the current reference temperature value if set starts to flash This is the setting screen If you want to calibrate the barometric pressure sensor press D to move the flashing to the middle display area This is the pressure sensor calibration screen At this time OFF or the barometric pressure value should be flashing on the display l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ...

Reviews: