CSN-58III user manual
48
When using connection structure, the middle need to insert FNC1 (C1H
Decimal = 193). input example is as follows:
GS 74 18 k "019501234567890 * 193" 029501234567890 * ""
When setting (HRI) print, control characters will replace with a space, and
remove FNC1 ~ FNC4.
Example
1b 40 1d 48 02
1d 6b 41 0c 31 32 33 34 35 36 37 38 39 30 31 32
1d 6b 42 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 43 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 44 08 30 32 33 34 35 36 30 30
1d 6b 45 08 30 32 33 34 35 36 30 30
1d 6b 46 08 30 32 33 34 35 36 30 30
1d 6b 47 08 41 32 33 34 35 36 30 41
1d 6b 48 08 41 30 32 33 34 35 36 41
1d 6b 49 08 41 30 32 33 34 35 36 41
⑥
2-D bar code printing commands
Mode type of 2-D bar code
Name
Mode type of 2-D bar code
Code
ASCII
:
GS (
k
pL pH cn fn n
Decimal
:
29
40
107 pL pH cn fn n
Hexadecimal
:
1D 28
6b pL pH cn fn n
Function
Setting mode type of two-dimension bar code to [n dot × n dot].
Parameter
range
pL=3, pH=0
cn=49
fn=67
0 ≤ n ≤ 16
Default
n=3
Notes
Setting mode type of QR code to [n dot × n dot].
Example
No
Horizontal error correction of 2-D bar code
Name
Horizontal error correction of 2-D bar code
Code
ASCII
:
GS (
k
pL pH cn fn n
DEC
:
29
40
107 pL pH cn fn n
HEX
:
1D 28
6b pL pH cn fn n
Function
Setting horizontal error correction of two-dimension bar code
Parameter
range
pL=3, pH=0
cn=49
fn=69