![Case IH MAXXUM 100 Service Manual Download Page 44](http://html1.mh-extra.com/html/case-ih/maxxum-100/maxxum-100_service-manual_2567490044.webp)
HYDRAULIC - PNEUMATIC - ELECTRICAL - ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER
SYSTEM
Charge pump - General specification
Type
Rotor Pump
Displacement
57 cm³/rev
(
3.48 in³/rev
)
Output (new pump) @
2200 RPM
(enginespeed)
143 l/min
(
31.5 UK gpm
)
37.8 US gpm
Charge Pressure Filter Dump Valve
Open @
6 bar
(
87 psi
)
Charge Pressure Limiting Valve
Open @
1.72 bar
(
24.9 psi
)
Charge Pressure Switch (making charge pressure warning light flash)
Close @
0.55 - 0.82 bar
(
8 - 11.9 psi
)