6039153 Rev. 0
1
T
RUCK REQUIREMENTS
GA0082.ill
GA0095.ill
Close
Forks
Sideshift
Right
Tilt
Forward
Hoist Up
Auxiliary Valve Functions
Check for compliance with ANSI standards:
WARNING:
Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Carriage –
Clean and inspect carriage
bars. Assure that bars are parallel and ends
are flush. Grind smooth any protruding
welds that may affect Sideshifter lower
bearings. Repair any damaged notches.
Tilt
Back
Hoist Down
Spread
Forks
Sideshift
Left
GA0028.ill
Carriage Mount Dimension (A)
ITA (ISO)
Minimum
Maximum
Class II
14.94 in. (380.0 mm)
15.00 in. (381.0 mm)
Class III
18.68 in. (474.5 mm)
18.74 in. (476.0 mm)
A
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
➀
55H
Min.
➁
Recommended
Max.
➂
Fork
3 GPM
4 GPM
5 GPM
Position
(11 L/min.)
(15 L/min.)
(19 L/min.)
Sideshift
1 GPM
2 GPM
3 GPM
(4 L/min.)
(7.5 L/min.)
(12 L/min.)
➀
Cascade H-Series Fork Positioners are compatible with SAE
10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-
5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
➁
Flow less than recommended can result in slow and unequal
fork movement.
➂
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Fork
Position