background image

10.3. CLEANING FUEL STRAINER:

Please note that dirt and water in the fuel are 

removed by the fuel strainer.

10.3.1. Remove the strainer cup and clean it properly 
by removing the water and dirt collected.
10.3.2. Clean the screen and strainer cup with petrol.
10.3.3. Fasten the cup tightly to the main body and 
ensure that there are no fuel leaks.

10.4. FUEL HOSE REPLACEMENT:

WARNING

Please take extreme caution when replacing the fuel 
hose as petrol is extremely flammable and dangerous. 

DO NOT SMOKE OR EXPOSE TO OPEN FLAMES 
whilst doing this.

10.4.1. Please ensure that the fuel hose is replaced 
every 500 hours. Do not attempt to do this whilst there 
fuel valve is open.
10.4.2. Please replace the fuel hose immediately 
should a leak develop or if the fuel hose is perished.

11. TRANSPORTING AND STORAGE:

11.1. Before transporting the generator please ensure 
that the fuel valve is in the “OFF” position.
Contact with a hot engine or exhaust system can cause 
severe burns and or fires, always allow for the engine 
to cool down prior to transporting and or storing.
Always ensure that the generator is transported and 
or stored in a flat horizontal position. Tilting of the unit 
may cause fuel spillage which may result in a fire.

11.2. Before storing the generator for an extended 
period of time please ensure that the area of storage is 
free from excessive water, dust and humidity. Please 
follow the table below:

Storage Time

Recommended Mainten-
cance

0-1 Month

•No preparation required

1-2 Months

•Drain out original fuel in 
the fuel tank and replace 
with clean fuel

2-12 Months

•Drain out original fuel in 
the fuel tank and replace 
with clean fuel
•Empty fuel from the 
carburetor
•Empty fuel from the fuel 
sediment cup

>12 Months

•Drain out original fuel in 
the fuel tank and replace 
with clean fuel
•Empty fuel from the 
carburetor
•Empty fuel from the fuel 
sediment cup
•Remove the spark plug 
and pour a teaspoon of 2 
stroke engine oil into the 
cylinder. Turn the engine 
slowly by pulling on the 
recoil starter. Reinstall the 
spark plug
•After removal from stor-
age, drain the stored fuel 
into a suitable container 
and replace with fresh fuel 
before starting. 

•Drain the carburetor by loosening the drain screw. 
Drain the fuel into a suitable container. Reinstall the 
drain plug.
•Having switched the fuel valve off, remove the 
sediment cup, empty the fuel, then reinstall the cup 
and secure it properly.

NEVER STORE THE GENERATOR INSIDE A HOUSE OR 

OFFICE. DO NOT STORE THE GENERATOR WHERE IT

IS SUSEPTABLE TO RAIN OR WATER.

12. TROUBLESHOOTING:

If the generator engine fails to start after several 
attempts and if there is no electricity available at the 
output socket then please check the chart below. If the 
generator still fails to start or generate electricity the 
please contact CREATIVE HOUSEWARES (see the back 
page of this manual for the contact details)

Summary of Contents for GEN2500

Page 1: ...2500W Petrol Generator PLEASE READ ALL INSTRUCTIONS BEFORE USE Model GEN2500 2500W ...

Page 2: ...he generator directly into a wall socket outlet 2 3 The generator should not be connected to other sources such as the power company supply mains In IMPORTANT Thank you for purchasing a Casals Petrol Generating Set hereinafter referred to as the generator This manual will assist you in operating and maintain ing your generator This manual is the latest version With the continuous improvement and u...

Page 3: ...is no longer than 65m 2 7 5 A 2 5mm2 flexible cable can draw a maximum of 16a provided that the cable is no longer than 45m 2 7 6 A 4mm2 flexible cable can draw a maximum of 10a provided that the cable is no longer than 100m 2 7 7 A 4mm2 flexible cable can draw a maximum of 16a provided that the cable is no longer than 65m 2 8 DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is...

Page 4: ...2500 12L WARNING Make sure you review each warning in order to prevent fire hazards Do not refill the fuel tank whilst the engine is running or hot Please ensure that the fuel valve is closed before refuelling Be careful not to contaminate the fuel with any dust dirt water or other foreign liquids objects Please clean all spilt fuel thoroughly before starting the generator Ensure that the generato...

Page 5: ...l objects 7 OPERATING PROCEDURES 7 1 STARTING THE GENERATOR ENGINE 7 1 1 Switch to the ON position FIG 1 7 1 2 Open the fuel valve FIG 2 7 1 3 Turn the choke lever to CLOSED position if the generator engine is cold Fig 3 7 1 4 Pull the recoil starter until resistance is felt FIG 5 7 1 5 This is the compression point Return the handle to its original position and then pull swiftly 7 1 6 Once the en...

Page 6: ...s 8 WATTAGE INFORMATION 8 1 Some appliances need a surge of energy when starting This is commonly known as a LAGGING Load 8 2 This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use 8 3 Electrical appliances and tools normally come with a label indicating voltage cycles Hz amperage amps and electrical power needed to run the app...

Page 7: ... plug and electrodes Replace spark plug Remove carbon from cylinder head note 1 Clean and adjust valve clear ance note 2 Clean and adjust carburetor note 2 Clean and replace carbon brushes Replace fuel lines Overhaul engine note 2 If and when needed 10 2 CLEANING AND ADJUSTING SPARK PLUG 10 2 1 If the spark plug is clogged with carbon please clean it using a plug cleaner or wire brush 10 2 2 Alway...

Page 8: ...orage is free from excessive water dust and humidity Please follow the table below Storage Time Recommended Mainten cance 0 1 Month No preparation required 1 2 Months Drain out original fuel in the fuel tank and replace with clean fuel 2 12 Months Drain out original fuel in the fuel tank and replace with clean fuel Empty fuel from the carburetor Empty fuel from the fuel sediment cup 12 Months Drai...

Page 9: ...is empty refill it CAUTION Do not overfill Check if the engine switch is in the OFF position Turn the engine switch to the ON position Ensure that the genera tor is not connected to an appliance If it is connected to an appliance turn off the power switch on the ap pliance and unplug it Test to see if the spark plug cap is loose If it is loose push the spark plug cap back tight Check the spark plu...

Page 10: ... specifically excluded from this guarantee Extended 24 Month Limited Warranty Casals takes pride in their product quality and therefore offer an extended 24 month limited warranty from the original date of purchase to offer the consumer peace of mind on their purchase Should defects due to faulty material or workmanship develop under normal domestic use within 24 months from the original date of p...

Page 11: ...HELPLINE 086 111 5006 ...