Technical data Maxiwell III LE
Please connect the adapter with the device and subsequently plug the power plug into the power
socket. Now turn on the device by the control panel.
With the car adapter the Maxiwell lll Limited Edition can also be used when travelling (not to be
used when driving!). Simply plug the car adapter in the cigarette lighter.
Measurements: 43,1 x 31,0 x 16,0 cm
Weight: 2,4 kg
Power source: input: AC 100-240V, 50~60Hz, 1200mA / output: DC 12V, 3000mA
Rated power: 36 watt
Operating time automatic: 15 minutes
Certificates:
SAFETY INSTRUCTIONS / ST
ART UP
TECHNICAL D
AT
A MAXIWELL III LE / E
Q
U
IP
M
EN
T
/
FU
N
C
T
IO
N
S
Please carefully read the following instructions before using this massage device to ensure its
proper function and optimal effect. Please retain these instructions for use!
•
This massage device complies with the recognised principles of technology and current safety regulations.
•
This equipment is maintenance free. Any necessary repairs must be performed by an authorised profes-
sional. Improper use and unauthorised repairs are prohibited for safety reasons and will void the warranty.
•
Never touch the power plug with wet hands.
•
Please avoid the equipment coming into contact with water, high temperatures and direct sunlight.
•
Be sure to unplug the equipment from the power point during extended periods of non-use to eliminate
the risk of a short circuit.
•
Do not use damaged plugs, cords or loose sockets. Damaged plug or cords must be replaced by the manu-
facturer, service representative or qualified personnel. In the event of malfunction unplug the equipment
immediately. We assume no liability for damages resulting from wrongful or improper use.
•
In order to prevent excessive stress on muscles and nerves, the recommended massage time of 30 minutes
should not be exceeded.
•
Never use pointy or sharp objects.
•
Any massage – also massage by hand – has to be avoided during pregnancy and/or in case of one or more
complaints in the area of the massage: recent injuries, thrombotic illnesses, inflammations and swelling of
any kind as well as cancer. Consultation of your physician is recommended prior to any treatment of af-
flictions and ailments.
•
Do not use the device while driving.
•
If you depend on electrical aids such as a pace maker, please consult your physician prior to usage in any
case.
Safety instructions
In the new Maxiwell III Limited Edition the massage heads normally made from plastic are substituted with heads
of proceed jade. The natural powers of jade are increased by an integrated heating system. The Massage will be
intensified by sending healing warmth into the depths of the muscles. The heat is permeating through the
stone slowly and is only noticeable after a few minutes. During this heating phase the tissue is already be-
ing relaxed by the rotating movement of the massage heads and surface hardening and tension are being
released. The optional vibration also allows for the stimulation of the circulation and lymphatic system. Blood
circulation is effectively improved and the purification facilitated.
Please position the Maxiwell III Limited Edition on a stable chair. The burden of your bodyweight intensifies
the massage effect. Please ensure that your whole body is positioned centrally so that the massage heads run
parallel to your spine.
The massage function will switch off automatically after 15 minutes. In order to increase the lifespan of the
motors, please switch on the massage heads again only after a minimum of 30 minutes have passed. This gives
the motors time to cool down again. You should also allow a period of rest for your body. We recommend
conducting the massages only two, maximum three times a day in order to not overstress your muscles.
For your own safety we equip the machines with a protection against overheating. Heat is cre-
ated in the motors when placed under great stress and excessive pressure. Before this could
create any risk, the machines will switch off automatically and will only allow switching on again
after an appropriate downtime between 30 and 40 minutes.