background image

4

CAUTION:  To  reduce  the  risk  of 

personal  injury,  use  only  the 

mounting hardware provided with 

the approved outlet box to install 

the crossbar mounting bracket.

CROSSBAR MOUNTING BRACkET INSTALLATION

CEILINg

wIRINg

CROSSBAR 

mOUNTINg 

BRACKET

FLAT

Washer

gREEN

gROUND

wIRE

CEILINg FAN

approVed

wIRINg BOX

RIDgE

SIDE

DOwN

CANOPY INSTALLATION

canopy lock 

Washer

canopy

SCREw

CROSSBAR

mOUNTINg

BRACKET

canopy

CANOPY HARDWARE

canopy

canopy

hatch

canopy lock Washer (4)

canopy screW (4)

approVed 

OUTLET BOX

hardWare

noTe:

 On sloped ceilings, align the 

canopy opening towards the top or 

room peak.

proceed with installation as follows:

Step 1.

 Route the wires from the ceiling outlet box through 

the  crossbar  mounting  bracket  center  hole.  Attach  the 

bracket, with ground wire and ridges down, to the ceiling 

fixture outlet box with the mounting hardware included with 

the outlet box. 

Tighten the screws firmly by 

hand

 only, being careful not to 

bend the bracket by over tightening.

Step 2.

 Attach the canopy to the crossbar mount-

ing  bracket  with  three  of  the  8-32  x  2

1

/

4

  long 

canopy screws and canopy lock washers.

Tighten the screw firmly by 

hand

 only.

Summary of Contents for at1008

Page 1: ...re within the canopy and that no wires are being pinched For best performance and for your warranty to be valid use only genuine Casablanca blades light fixtures and accessories Safety and the proper...

Page 2: ...imum of 7 above the floor Do not locate the fan in a doorway or above a swinging door In any installation the tips of the blades must be at least 18 from the wall in order to provide sufficient cleara...

Page 3: ...nch loosen the set screw several turns to allow installation of the downrod Thread the downrod into the motor coupling until it stops turning this will take at least four and a half full turns Step C...

Page 4: ...Y SCREW 4 approved outlet box hardware Note On sloped ceilings align the canopy opening towards the top or room peak Proceed with installation as follows Step 1 Route the wires from the ceiling outlet...

Page 5: ...ACK power wire from fan to BLACK power wire in ceiling outlet box Secure with wire nut Step 4c W 80 Wiring Connections GREEN leads from mounting plate and fan to GROUND conductor of power source Secur...

Page 6: ...ndard Style Attach the blades to the blade holders with the three blade screws and felt washers provided for each blade Hand tighten securely BLADE BLADE SCREW 3 PER BLADE BLADE HOLDERS HARDWARE STAND...

Page 7: ...the switch box 2 Pull the existing switch from the switch box to expose the wire connections 3 Determine which wire is connected to the common ter minal of the 3 way switch The terminal will be marked...

Page 8: ...vel of speed turn the fan on by pressing less than one second To lower speed turn fan off then on by pressing and holding the button until the desired speed is reached When the fan is on you may incre...

Page 9: ...cate this command has been accepted This program overrides all manual control of lights and fan The lights will now be automatically cycled on and off in a controlled sequence as follows On 1 hour off...

Page 10: ...sure the power is turned off during this inspection FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball EXCESSIVELY Check the screws holding the blade holders to the fan...

Page 11: ...al fan only Wall Controls The W 40 and W 24 wall controls provide four speed control of fan from a convenient wall loca tion The W 40 and W 24 are designed to replace a standard wall switch and will f...

Page 12: ...4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by the W...

Page 13: ...sure all screws in the motor housing are snug but not overly tight Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices T...

Page 14: ...2000 Blade Span 42 or 50 Blade Iron Pitch 16 No of Blades 5 Technology 3 Speed Inteli Touch W 32 Airflow 6 105 cfm Electricity Use 106 watts Airflow Efficiency 57 8 cfm watt Performance data is for f...