TEST 3
FUNCTION : Load cell test and A/D conversion
Key
Display
Description
Enter : Move to the
next menu.
Other Keys :
Perform Test.
tESt
3
TEST 3 condition
Display digital value of current
weight.
This value means converted digital
value under actual condition.
If you press Enter key, it will be
moved to test 4.
Ref 1. A/D converter test is automatically completed by displaying converted
digital value of current weight.
Ref 2. L/C test is also completed by loading the weight on the platform.
Check whether digital value is changing.
If the digital value is fixed or zero is displayed, please check the
connection of the load cell.
TEST 4
FUNCTION : Serial Interface / Printer test
Key
Display
Description
ENTER: Exit from the
Test Mode
Other Keys :
Perform Test
tESt 4
Test 4 condition
- - - -
Press Enter key.
GOOD
2601P
It will be moved to Normal Mode
after test mode.
Ref 1. Perform test only when the printer connection are installed.
Ref 2. "GOOD" message is displayed if the printer connection and specification
is done correctly. If or not, "ERR 6" message is displayed.
Ref 3. The test output format of printer is as the follows.