6
Service Manual –
PB Series
REV NO
:
2
4. Calibration Mode
4.1. General Calibration
Pressing and holding calibration switch press [POWER] key to go to calibration mode.
User can move to other mode by using [ZERO] key in the calibration mode.
User also moves to other sub-modes for each mode by using [TARE] key.
Please simply follow below procedure to move to other mode.
(1)
Calibration Mode: Pressing and holding
“
Calibration Switch
”
press [POWER] key.
(2)
It displays
“
CAL-0
”
after
“
CAL
”
, and it blinks the version of scale three times.
(3)
Selecting menu: press [TARE].
(4)
ENTER(Setting) : [TARE] key
MODE
Function
CAL 1
Display normalized AD
CAL 2
Display Keypad infomation-
CAL 3
Weight Setting Mode
“UnLoad”
[TARE]
→
→
“MIDD”
[TARE] after loading for 1/3 weight
→
→
“FULL”
[TARE] after loading for Full weight
→
→
“MIDD”
[TARE] after loading for 1/3 weight
“END”
→
→
CAL 4
Option Setting ( Refer to Table 1)
CAL 5
Display filtered Raw AD
CAL 7
% Calibration
CAL 8
Battery calibration
CAL 9
Gravity constant
CAL 10
Set calibration factor
“Unit”
[TARE]
select 0, 1 (0:kg, 1: lb)
[TARE]
“CAPA”
[TARE]
select capacity
[TARE]
“MCAPA”
[TARE]
select mid-capacity
[TARE]
“W-dP”
[TARE]
Select Decimal Point
[TARE]
“ 1 d ”
[TARE]
Select division
[TARE]
“Dual”
[TARE]
Enable dual interval (0:disable, 1:enable)
[TARE]
“tare”
[TARE]
Enable custom tare (0:disable, 1:enable)
[TARE]
CAL 11
Set nation(00 : OIML , 01 : NTEP , 02: KOREA)
Summary of Contents for PB Series
Page 16: ...16 Service Manual PB Series REV NO 2 8 1 2 Scale Ass y ...
Page 17: ...17 Service Manual PB Series REV NO 2 8 2 Loadcell Ass y ...
Page 18: ...18 Service Manual PB Series REV NO 2 8 3 Main PCB Ass y Top 8 4 Main PCB Ass y Bottom ...
Page 19: ...19 Service Manual PB Series REV NO 2 8 4 1 Main PCB Part List ...