17
F 4
FUNCTIN : Weight Backup
KEYS
LCD SCREEN Setting value
DESCRIPTION
00
01
Not use
Use (Zero, Tare, Status)
F 5
FUNCTION : Hold Type
KEYS
LCD SCREEN Setting value
DESCRIPTION
00
~
0.9
Average
Hold
Peak
Hold
Calculate the average of
moving weight
Calculate the peak of
moving weight
Description of HOLD Function
1. When the F5 is set to 00
Case 1
( When the hold key is pressed in unloaded state) : Auto-Average Hold Function
If you press the Hold key in unloaded state, after displaying the and
the Hold function Is started.
Just When the weight is changed(above the 1divison) , being displayed
and the changed weight is hold
If you want to release the Hold function, have to press Hold key in unloaded
state certainly
When the Hold function is released, being displayed the message
Case 2
(When the hold key is pressed in loaded state) : Manual Hold Function
When you want to hold the current weight, just press Hold key.
After displaying the and the Hold function Is started.