11
3. Counting Mode
■ Samples on the platter.
①
Press the MODE key until
the display shows “WL OFF”.
If you have set sample size
before the display shows “0”.
②
Press the SAMPLE key,
then the display shows “10”.
③
If you want to increase
sample size, press the
SAMPLE key. The display
shows 10, 20, 50, 100, 200
every time pressing the
SAMPLE key.
If you set sample size to 10, place 10 samples on the platter.
④
⑤
Press the SET key. The display shows unit weight and then shows the number of samples. If the
display shows “LACK”
*
The small value that can escape from ‘LACK’ message is over MAX CAPA / 3000.
a. unit weight ≤ 0.8 e *
b. weight load ≤ 2% of maximum weighing capacity.
⑥
Place parts on the platter, then the display shows the number
of parts. You can also use tare function in counting mode.