10
■
SUM Key
Used to print total weight of previously weighed result by ID number.
For example, let's assume that the current specified ID number is 4.
The print form is as belows.
---------------------------
SUM TOTAL
---------------------------
DATE : 1997. 9. 25
TIME : 9:30
ID : 14
COUNT : 5
TOTAL : 350.0 kg
After printing is done, the total weight and count corresponding to the
ID number is initialized to 0.
■
TOT Key
Used to print total weight regardless of ID number.
The print form is as belows.
---------------------------
OVERALL TOTAL
---------------------------
DATE : 1997. 9. 25
TIME : 9:30
ID : 14
COUNT : 5
TOTAL : 350.0 kg
After printing is done, the total weight and count remains.
■
ID Key
Type "ID" key, the ID code using by numeric key and then the ID code
is registered. The code range is from 0 to 4.
■
PRT Key
Print key.
If this key is pressed, the print format you chose in set mode (see function F06)
is to be printed.
■
G/N Key (Gross/Net key)
Toggle key between GROSS weight and NET weight. The annunciators and
display will alternate between GROSS and NET as well.
In case tare weight is REGISTERED, tare and item's total weight is G.
weight and only item's weight is N. weight.