background image

 
 

 

28

 

D. Stable class range 

 

Keep pressing 

ENTER 

key in USER PROGRAMMING MODE until the display  

appears as below.

 

 

 

 

 

 

There are 6 options, and Pressing 

MOVE

  key is possible to rotate among the options.   

(

Default setting:

 1)

 

( 0=off, 1=0.05d, 2=0.151d, 3=0.25d, 4=0.35d,5=0.45d)

 

 

If you want to exit, press 

C

  key to  confirm and go back to normal weighing mode.

 

However, if you want to keep going to set other menus, press 

ENTER

 key to confirm and  

move on next. 

 

Please turn off the scale after setting.

 

 

 
 
E. Stable class rate 

 

 

Keep pressing 

ENTER 

key in USER PROGRAMMING MODE until the display appears as 

below.

  

 
 
 
 
 

 

 

There are 5 options, and Pressing 

MOVE

  key is possible to rotate among the options.   

(

Default setting:

 1)

 

Level : 1, 2, 3, 4, 5 
The larger number is more stable.

 

 

If you want to exit, press 

C

  key to  confirm and go back to normal weighing mode.

 

However, if you want to keep going to set other menus, press 

ENTER

 key to confirm and  

move on next. 

 

Please turn off the scale after setting.

 

 

Summary of Contents for ECB Series

Page 1: ...2 ...

Page 2: ...ty accumulation 21 G Preset counting check range 22 H Preset weight check range 24 7 User Programming Functions 26 A Auto shut off time setting 26 B Zero Tracking range 27 C Zero display range 27 D Stable class range 28 E Stable class rate 28 F Backlight type 29 G Change unit of measure from kg to pound 30 H Unit weight recomputing 31 I Check alarm type 32 J Baud rate setting 34 K Transmit method ...

Page 3: ...4 8 Calibration can be done in kg lb 36 9 Power supply battery operation 37 10 RS 232 Output 38 11 Error Codes 45 12 Technical Data 46 ...

Page 4: ...5 1 Precautions Before Using The Scale ...

Page 5: ...6 ...

Page 6: ...netic fields or equipment that generates magnetic fields On an unstable work surface In a dusty environment In direct sunlight Leveling the Scale The scale is equipped with a level indicator on the back side at the middle of platform and four adjustable leveling feet Adjust the leveling feet until the bubble appears in the center of the circle Turn on Scale Do not turn on scale with anything on th...

Page 7: ...8 2 Overall view ...

Page 8: ...and insert the post pipe to the post bracket Refer to fig 1 4 Fasten the post pipe with two bolts Refer to fig 1 5 Insert the wire to the post pipe Refer to fig 2 3 6 If the scale is not properly level please adjust 4 leg adjusting bolt at the bottom of the scale so as to center the bubble of the leveling gauge Note Place the scale on a flat and stable surface Inside the indicated circle ...

Page 9: ...10 Note Beforeusingthescale unscrewthefiveshippingprotection screws Ifnot theweighingoperationworkswrong 1 Location of screws 2 Adjusting procedure ...

Page 10: ...rm 2 Indicated Symbols Sysmbols Specification ScaleisinTAREmode ScaleisinZEROmode ScaleisinACCUMULATIONmode ThedisplayreadingisinSTABLEcondition LackofSampleWeight Ifthetotalsampleweightontheplatformislessthan10displaydivisions atriangularindicatorwillappeartoremindtheusertoaddmoresamples untiltheindicatordisappears LackofUnitWeight Iftheunitweightislessthe1 10displaydivisions atriangularindicator...

Page 11: ...clearthedisplay Usethiskeytosubtractthecontainer sweight indicatesthatthecurrent weightreadingisnetweight Usethiskeytoinputsamplesize Usethiskeytoinputtheknownunitweightofitemtobecounted UsethiskeytoinputtheHIGH LOWweight quantitylimitforcheck function Usethiskeytoaccumulateweight quantitymeasured Usethiskeytorecalltotalweight count accumulationontimes UsethiskeytopresetTAREweight ...

Page 12: ...UsethiskeytoenterintoUserProgrammingFunctions Usethiskeytoconfirmtheparametersetting UsethiskeytomovetheparametervalueinSetMode Usethiskeytomemoryavaluetoalocation Usethese24blankkeystostorevaluesinmemory ...

Page 13: ...oaded C Sampling before counting 1 Unknownunitweight Placeafewpiecesofitemtobecountedontheplatform Inputthequantityofitemontheplatform ex 50pcs PressSMPLkey Note Thesystemdefaultis UnitWeight Ifthe SMPL keyisclickedwhenthevalue ex 40 in COUNTwindowisblinking thenthenumericalvalueinputwillbeas Quantity Ifthe SMPL keyisnotclickedwhenthevalue ex 40 inCOUNTwindowisblinking thenthenumericalvalueinputwi...

Page 14: ...unitweightduringincountingprocessifthesettingof UnitWeightRecomputing setto on 2 Knownunit weight Inputtheknownunitweight ex 40g PressU Wt keyto completesamplingoperation enterintocountingmode Note Thesystemdefaultis UnitWeight Ifthe U WT keyisclickedwhenthevalue ex 0 in COUNTwindowisblinking thenthenumericalvalueinputwillbeas UnitWeight ...

Page 15: ...g AfterinputU W pressENTER keytotoConfirmitandmoveonthenextstep Note PresstheMOVEkeytochangethevaluewhenawrongvalueisentered ThesecondstepisforstoringTarevalue So Inputthetarevalue ex 10kg andpressthe ENTERkeytoconfirmitandmoveonthenextstep Thethirdstepisforstoringitemnumber So Inputtheitemnumber ex 800125 andpressthe ENTERkeytoconfirmitandmoveonthenextstep Note Youcanenterupto6digits ...

Page 16: ...y InputanaddressnumberbyusingNumerickey 1 100 andPressENTERkeytoconfirmit Then thescalewillbebacktothenormalcountingmodedirectly 1 Anerrormassage E4 appearsiftheaddresscodeisoutof 1 100 ThenpressMOVEkeytoreturntolaststep PressCANCELkeytoexitthestoringmode 2 Whentheaddressnumberhasbeenused thedisplaywillbeshownasbelow Atthistime ifyouwanttostillusetheaddressnumber pressENTERkeytoconfirmit Ifyouwant...

Page 17: ...dressnumberbyusingnumerickeyswhichyouwanttorecallandthenpressMEMORYkey Twice rapidly 1 Placepartsontheplatform youwillknowthenumberofparts 2 PresstheCkeytoexitfromrecallingmemorymode 3 PresstheU WTkeyduringrecallingmemorymodetocheckaddress itemnumber E Subtract container s weight 1 Weight unknown Placeacontainerontheplatform Press TARE key ...

Page 18: ...ctionwell indicatorsof stable Net weight willappearasbelow 2 Container s weight known Withnoweightontheplatform Nothingontheplatform PressP TAREkey Inputcontainer sweightvaluebyusingnumerickeys ex 0 96kg Press P TAREkeyagain ...

Page 19: ...r sweightvaluebyusingnumerickeys ex 0 5kg Press P TAREkeyagain Eliminate TARE Remove all weights from the platform If so the weight display will show a negative container s weight Atthismoment PressingTAREkeywillbringthe weightdisplaytozero ThenTAREindicator willbedisappeared ...

Page 20: ...Followingtotheprocessabove youcanaddupwhateveryouwantcontinuously AfterthenpressTOTALkey ThenthetotalweightwillbeshownonWEIGHTwindow thetotalcountwillbeshownonCOUNTwindowandthenumberofaccumulation willbeshownonUINTWEIGHTwindow Press TOTALkeytoenterintoaccumulationstatusmode Atthismoment totalaccumulated weightisshownonWEIGHTwindow totalaccumulatedtimesisshownonUNITWEIGHT windowandTOTALPIECESisshow...

Page 21: ...ndowshouldbezeroedbeforethenextaccumulation G Preset counting check range UsercansetaHi Lorangeforcheckingthequantityofcountingresult whenthenumber ofobjectsontheplatformmeetthe conditionoftherange thealarm willsoundbeeps repeatedly 1 Procedures Doesn tmatterwhatsomethingisontheplatform PressALARMkey Thenthedisplay imageisshownasbelow Inputdesiredhighlimitvaluebyusingnumerickeys ex 200pcs Itisposs...

Page 22: ...keys ex 5pcs Lowlimitvalueiseffectiveonlyafterhighlimitispreset PressSMPLkeytocompletethisprocedureandreturntonormalcountingmode Note Anerror massage E5 appearsin weight windowwhentheLOvalueissethigher thanHIvalue Afewsecondslater it willbacktolimitsettingmodeagain LO value ex 5pcs High value ex 200pcs ...

Page 23: ...edures Doesn tmatterwhatsomethingisontheplatform PressALARMkey Thenthedisplayimageisshownasbelow Inputdesiredhighlimitvaluebyusingnumerickeys ex 30kg ItispossibletoerasewrongvalueasusingCLEARkey PressALARMkeyagaintoconfirmHIvalueandmoveonnextsteptoinputLOvalue InputdesiredLOlimitbyusingnumerickeys ex 2kg Lowlimitvalueiseffectiveonlyafterhighlimitispreset LOvalue ex 2kg HIvalue ex 30kg ...

Page 24: ...n weight windowwhentheLOvalueisset higher thanHIvalue 2 When both HI and LO values are needed they must be kept same decimal digits Ex HI 10kg LO 9 8kg then the values must be set as HI 10 0kg LO 9 8kg Clear high low value preset Input 0 orClearkeytodeletepriorHI LOvalues when youareinlimitsettingmode ...

Page 25: ...utomatically A Auto Shut off time setting Asshownbelow thesettingvalueisonWEIGHTwindowandthetitleofmenuisonU W window Thereare4options andPressingMOVEkeyispossibletorotateamongtheoptions Options Description 0 Defaultsetting Nousethisfunction 2 Thescalewillbeturnedoffautomaticallyafter2min ifthereisnoanyinterruption 5 Thescalewillbeturnedoffautomaticallyafter5min ifthereisnoanyinterruption 8 Thesca...

Page 26: ...ttokeepgoingtosetothermenus press ENTER key toconfirmand moveonnext Pleaseturnoff thescaleaftersetting C Zero display range Keep pressing ENTER key in USERPROGRAMMINGMODE untilthe display appearsasbelow Thereare5options andPressing MOVE key ispossibletorotateamongtheoptions Defaultsetting 2 0 off 1 0 5d 2 1d 3 2d 4 3d Ifyouwanttoexit press C key to confirmandgobacktonormalweighingmode However ifyo...

Page 27: ...ouwanttokeepgoingtosetothermenus press ENTER key toconfirmand moveonnext Pleaseturnoff thescaleaftersetting E Stable class rate KeeppressingENTERkeyinUSERPROGRAMMINGMODEuntilthedisplayappearsas below Thereare5options andPressing MOVE key ispossibletorotateamongtheoptions Defaultsetting 1 Level 1 2 3 4 5 Thelargernumberismorestable Ifyouwanttoexit press C key to confirmandgobacktonormalweighingmode...

Page 28: ...aticallywheneverthescaleisloadedbyobjectsweigh greaterthan9displayresolutionoranyofkeysispressed Anditwillbegoingoffalso automaticallyapprox 5secondsafterthescalereturnstozero 1 Manualbacklight Press decimal point key to switch on and offbacklight Ifyouwanttoexit press C key to confirmandgobacktonormalweighingmode However ifyouwanttokeepgoingtosetothermenus press ENTER key toconfirmand moveonnext ...

Page 29: ...ay appearsasbelow Thereare2options andPressing MOVE key ispossibletorotateamongtheoptions Defaultsetting 0 0 kg 1 lb Ifyouwanttoexit press Clear key to confirmandgobacktonormalweighingmode However ifyouwanttokeepgoingtosetothermenus press ENTER key toconfirmand moveonnext Pleaseturnoff thescaleaftersetting ...

Page 30: ...setothermenus press ENTER key toconfirmand moveonnext Theunit weight willbeaveraged againif youaddtheremainingquantity gradually byseverallots This willhelpeliminateerrorscaused bythepossibleweight variationamongeachobjectand leadtomore accurateresults Whenaddingobjectstotheplatform Theweight valueshouldnotbelessthan 10displaydivisions besurethatthequantityisLESSTHANthosealreadyon theplatform Thea...

Page 31: ...ay appearsasbelow Thereare2options andPressing MOVE key ispossibletorotateamongtheoptions Defaultsetting 0 0 Insidetype 1 Outsidetype Ifyouwanttoexit press C key to confirmandgobacktonormalweighingmode However ifyouwanttokeepgoingtosetothermenus press ENTER key toconfirmand moveonnext ...

Page 32: ...ncountdisplaywindow willflicker 2 Outside type Thealarmsoundsbeepsonlywheneithertotalweightortotalcountisoutsidethesetrange Ex checkingthecount weightwhenoverHIvalue Ifthecount weightisoverHIvalue thevalueoncountdisplaywindow willflicker Ex checkingthecount weightwhenunderLOvalue Ifthecount weightisunderLOvalue thevalueoncountdisplaywindowwillflicker Pleaseturnoff thescaleaftersetting ...

Page 33: ...ersetting K Transmit method setting Keep pressing ENTER key in USERPROGRAMMINGMODE untilthe display appearsasbelow Thereare4options andPressing MOVE key ispossibletorotateamongtheoptions Options Description 1 transmitbypressingakey ex TicketprinterDEP 50 PC 2 seriestransmit ex TicketprinterDEP 50 PC 3 Defaultsetting transmitbypressingakey foralabelprinter DLP 50 4 auto transmit foralabelprinter DL...

Page 34: ...ng Keep pressing ENTER key in USERPROGRAMMINGMODE untilthe display appearsasbelow Thereare10options andPressing MOVE key ispossibletorotateamongtheoptions Defaultsetting 1 1 Thetarecanbecanceledcontinuously 2 Thetaremustbecanceledforonetimeonly Note Whenuseristryingtocanceltarevalue Ifthevalueisnotthesameastotaltarevalue thebuzzerwilltweetforthreetimestoindicatetheerror Then Removealltheweightfrom...

Page 35: ...capacityisdisplayedonU Wwindowbecausefullcapacityisrequiredfor calibration However weightcapacityforcalibrationispossibletosetbyyourselfasinputting numerickeys Aftermadeadecisionwhatcapacitywillbeusedforcalibration puttheweightontheplatform assameaswhatexactlyshownontheU Wwindow Thenthescaleiscalibratedautomatically andthescaleisbacktonormalweighingmodeafewsecondslater PressCLEARkeytoescapeformcal...

Page 36: ...ically switch off to protect the battery Before switching off automatically a prompt words Lobatoff willbeshownthreetimestoindicatethescaleswitchoffduetobatteryempty Thebatteryshouldbechargedfor12hoursforfullcapacity ThereisanLEDtoindicatethestatusofbatterychargingonthedisplay IftheLEDisGreenthe battery has been charged If it is Red the battery is nearly discharged and Yellow indicates the battery...

Page 37: ...n3 Output Pin5 SignalGround Data di gi t specification 12345 6 78910111213 141516 1718 1 st row Netweight Data title space data unit CR 2 nd row Unitweight data title space data unit CR 3 rd row Quantity data title space data CR 1415 4 th row Tareweight data title space data weight CR 4 th rowdata OA 3 DataFormatofSeriestransmit Whenitisinunstablemode net 15 000 kg U W 1000 g pcs 10 Tare 5 000 kg ...

Page 38: ...tionmodeandtransmitbypressing ADD keyand TOTAL key PresstheADDkey PLU100 No 800125 Record 01 NET 15 000kg U W 100 00g PCS 100 Tare 5 000kg PresstheADDkeyagain PLU100 No 800125 Record 02 NET 10 000kg U W 100 00g PCS 80 Tare 2 000kg PresstheTOTALkey TOTAL PLU100 No 800125 NET 25 000kg pcs 180 Note Whenitisinnormalcounting model withoutaccumulationoperation pressthe TOTAL key to print the data the tr...

Page 39: ...NET 15 000kg U W 100 00g PCS 100 Tare 5 000kg Whenitisinunstablemode TOTAL net 15 000kg U W 100 00g pcs 100 Tare 5 000kg NET StableNetWeight net UnstableNetWeight PCS StableQuantity pcs UnstableQuantity U W UnitWeight Tare Tarevalue ...

Page 40: ...PressADDkey Weight 6 48kg Unitweight 20 25g Quantity 320pcs Tare 0 035kg PressADDkeyagain Weight 4 55kg Unitweight 20 25g Quantity 220pcs Tare 0 035kg PressTOTALkey Weight 10 935kg Unitweight 20 25g Quantity 540pcs Tare 0 035kg used comma with EAN13barcode ...

Page 41: ...y Transmitmethodsettingisset 1 Command 1byte Char Hex WeighingMode 1 0x31 Sameas1key 2 0x32 Sameas2key 3 0x33 Sameas3key 4 0x34 Sameas4key 5 0x35 Sameas5key 6 0x36 Sameas6key 7 0x37 Sameas7key 8 0x38 Sameas8key 9 0x39 Sameas9key 0 0x30 Sameas0key 0x2E Sameas key 0x43 C c 0x63 SameasC Clear key ...

Page 42: ...U u 0x75 SameasU WTkey 0x41 A a 0x61 SameasALARMkey 0x45 E e 0 0x65 SameasENTERkey 0x52 R r 0x72 SameasMEMORYkey 0x50 P p 0x70 SameasP TAREkey 0x4E N n 0x6E SameasADDkey 0x5A Z z 0x7A SameasZEROkey 0x54 T t 0x74 SameasTAREkey 0x44 D d 0x64 SameasTOTALkey 0x4C L l 0x6C SameasLongpressMEMORYkey ...

Page 43: ...odot 6 byte TWC Tareweight withcomma 7 byte GWA Grossweight withdot 7 byte GWB Grossweight nodot 6 byte GWC Grossweight withcomma 7 byte TNA Totalnetweight withdot 7 byte TNB Totalnetweight nodot 6 byte TNC Totalnetweight withcomma 7 byte UWA Unitweight withdot 7 byte UWB Unitweight nodot 6 byte UWC Unitweight withcomma 7 byte QUA Quantity withdot 7 byte QUB Quantity nodot 6 byte QUC Quantity with...

Page 44: ... on the scale with something on the platform Take away all goods from the platform and switch on again E4 Address cell is out of 1 100 Correct the operation E5 In alarm setting the LO value is set higher than HI value Correct the operation OL Overload or value exceeds the display range Correct the operation Iftheerrormessagestillisshownevenafterfollowingtodescription pleasedocalibrateagain Afterth...

Page 45: ...0 2lb 0 5lb 0 2g 0 5g 1g 2g MinRecommended LackofUnitWeight 0 0005lb 0 001lb 0 002lb 0 005lb DisplayType LCD WeightUnits kgorlb ZeroRange 2 TareTange FullCapacitybySubtraction StabilizationTime 2seconds OperationTemperature 0 40 32 104 HumidityRange 90 relativehumidity non condensing Power ACAdaptorDC12V 1Aor12V 800mA Internalrechargeablesealedacidbattery BatteryLife 100hourscontinuoususewith12hou...

Page 46: ...47 ...

Page 47: ...48 ...

Reviews: