lamp 3 is turned on. The relays of the receivers 1, 2, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the 
lamps 1, 2, 4 are turned off.

 

Press button 4 of the transmitter: The relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and C), and the 
lamp 4 is turned on. The relays of the receivers 1, 2, 3 are deactivated (disconnect the terminals B and C, connect the terminals A and C), and the 
lamps 1, 2, 3 are turned off.

 

 

Wired control terminals:

 

The receiver has wired control terminals, and you can connect external devices, sensors, or manual switches to the receiver's manual terminals, then 
use them to trigger the receiver.

 

1) By low level signal:

 

You can connect external devices (with low level output signal) to terminal 1 

(Signal−),

 and terminal 2 (), then the external device’s output 

signal can control the receiver.

 

When the external device outputs low level signal to terminal 1 and 2, the relay is activated (connect the terminals B and C, disconnect the terminals 
A and C), and the lamp is turned on.

 

When t

he 

external 

device 

stops

 to output

 signal, the relay is deactivated (disconnect the terminals B and C, connect the terminals A and C), and the 

lamp is turned off.

 

 

 

2) By NO/NC contact:

 

You can connect manual switch to terminals 1 and 2, then you can use manual switch to control the receiver.

 

When connect terminals 1 and 2, the relay is activated (connect the terminals B and C, disconnect the terminals A and C), and the lamp is turned on.

 

When disconnect terminals 1 and 2, the relay is deactivated (disconnect the terminals B and C, connect the terminals A and C), and the lamp is 
turned off.

 

 

How to pair the transmitter to the receiver:

 

1) Press the learning button of receiver, signal LED on the receiver is on, it means the receiver enters the learning status.

 

2) Press any one button on transmitter, if signal LED flashes quickly 15 times and turns off, it means learning is successful.

 

3) When receiver is in the learning status, press again the learning button, if signal LED turns off, it means learning process was discontinued.

 

4) The receiver can learn several transmitters with different codes.

 

 

Delete all transmitters:

 

We have learned transmitter to the receiver. If you don’t want the receiver to work with the transmitter, you can delete all codes of transmitters, which 
are stored in the receiver.

 

Operation: Press and hold the learning button of receiver until signal LED flashes slowly; then release the button, signal LED keeps slow flash. That 
means all stored codes have been deleted successfully.

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 0020301

Page 1: ... same place A 4 button transmitter controls 4 single channel receivers and each button controls a receiver Receiver Parameters Model No S1PU DC06 ANT3 S1PU DC09 ANT3 S1PU DC12 ANT3 S1PU DC24 ANT3 Power Supply Operating Voltage DC6V S1PU DC06 DC9V 1V S1PU DC09 DC12V 1V S1PU DC12 DC24V 2V S1PU DC24 Output Relay output Normally open and normally closed Working Voltage Range of Relay AC110 240V or DC0...

Page 2: ...ay of the receiver 4 is activated connect the terminals B and C disconnect the terminals A and C and the lamp 4 is turned on Press button 4 of the transmitter again The relay of the receiver 4 is deactivated disconnect the terminals B and C connect the terminals A and C and the lamp 4 is turned off 2 Setting Momentary mode Only connect Jumper 1 Mode Momentary working with transmitter C 4 Press and...

Page 3: ...activated disconnect the terminals B and C connect the terminals A and C and the lamp is turned off 2 By NO NC contact You can connect manual switch to terminals 1 and 2 then you can use manual switch to control the receiver When connect terminals 1 and 2 the relay is activated connect the terminals B and C disconnect the terminals A and C and the lamp is turned on When disconnect terminals 1 and ...

Page 4: ... Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A _ DC Power Supply AC Power Supply Control AC Lamp Relay CN2 CN1 Status LED Power LED Signal LED Learning Button External Device RF module Antenna Signal Signal L N C B A Live wire Neutral wire AC Lamp DC Lamp 2 1 1 2 B C Normally Open A C Normally Closed B C Normally Open A C Normally Closed ...

Reviews: