13
nozzle into the waste opening. Hold nozzle firmly against the deck fitting to ensure a tight seal. Turn on
pump and open valve located on handle. When pumping is finished, close lever on handle and turn off
pump. Remove from deck fitting.
If there is a fresh water hose on the dock, rinse the tank by adding 2 minutes of water into tank. Then re-
pump to leave the tank rinsed for the next charter. This also eliminates head odors.
#2 The tank’s contents can be discharged with the OB MACERATOR only in Canadian waters.
To operate the macerator, confirm the overboard discharge valve is open. It is located on the port side in
the engine room forward of the port engine. Push the Waste Pump breaker on the DC electrical panel.
Listen to the macerator’s sound. When the pitch becomes higher, the tank is empty. Discharge may be
observed on the port side. It should only take a few minutes to empty the tank.
WATER SYSTEM
Fresh Water Tank(s)
The FRESH WATER TANK(S) hold 95 gallons. Observe the water level by turning on the Water
Monitor breaker on the DC panel. Waste water from the sinks and showers drains into a sump box and is
then pumped overboard automatically. Ensure the Sump Pump breaker is turned on.
To refill the tanks, remove the WATER CAP(S) located under the bulwark gates located port and
starboard just ahead of the side cockpit doors. Avoid flushing debris from the deck into the tank opening.
DO NOT fill water and diesel at the same time!
Fresh Water Pressure Pump
The WATER PRESSURE PUMP is located in the under-cockpit storage area on the starboard side near
the batteries. Activate pump at the DC panel by turning on the breaker. If the water pump continues to
run, you are either out of water or might have an air lock and need to bleed the system by opening up a
faucet. If you run out of water SHUT OFF YOUR HOT WATER HEATER on the AC panel. Serious
damage can occur!
Hot Water Tank
The HOT WATER HEATER has an 11-gallon capacity tank and is available when connected to shore
power or via a heat exchanger underway. To use on shore power, flip on the water heater circuit breaker
on the AC electrical panel. Do not use the water heater if the water tank level is very low. The water
heater is located starboard side aft salon.
Shower