10
CONTROLLER PROGRAMMING (continued)
TO CHANGE THE TEMPERATURE SCALE
Press the TEMP KEY until the temperature starts flashing. Then, press
both the up and down arrow buttons (together) until ‘F’ (Fahrenheit) is dis-
played.
Press the up or down arrow keys to toggle between ºC and ºF.
Once selected, press the TEMP KEY to save and exit.
To enter into program
mode, display must be in
operating mode and not
in a timing cycle .
NOTE:
Each module can
be programmed individual-
ly.
Rear display cannot be
programmed.
TEMPERATURE
SETPOINT RANGE:
122ºF - 225ºF
(50
°
C - 107
°
C)
TEMPERATURE
DEFAULT SETPOINT:
195ºF (91
°
C)
TIMER RANGE:
1 minute to 9 hours, 59
minutes.
NOTE:
Timers cannot be
programmed for less than
1 minute.
NOTE:
While in the pro-
gram mode, if no key is
pressed for 10 seconds,
any changes will be saved
and the control returns to
normal operation mode.
NOTE:
The technical content of this
manual, including any wiring
diagrams, schematics, parts
breakdown illustrations and/
or adjustment procedures, is
intended for use
ONLY by
qualified technical person-
nel
.
PROGRAM TIMERS (P1 through P6)
1. Press and hold TIME KEY
until digital readout flashes.
2. Press INCREASE KEY
to add time. Each time key is pressed, timer
is increased by 1 minute. Hold key to scroll faster.
3. Press DECREASE KEY
to subtract time. Each time key is pressed,
timer is decreased by 1 minute. Hold key to scroll faster.
4. Press TIME KEY
to save changes and return to P1.
5. To program timers P2 through P6:
A. Press INCREASE KEY
or DECREASE KEY
to select the
desired
program.
B. Repeat steps 1 through 4 above for each program
TO
CANCEL
TIMER:
Press and hold TIME KEY for 2 seconds.
DIGITAL READOUT
INCREASE KEY
DECREASE KEY
TEMPERATURE KEY
TIME KEY
POWER INDICATING LIGHTS FOR TOP
AND BOTTOM HEATERS (EACH CAVITY)
NOTE:
“P1” must be displayed
before temperature scale
can be changed. If “P1” is
not displayed, press
ARROW KEY to display
“P1.”