background image

CONTROL PANEL LAYOUT 

On/Off Toggle 
Switches 

Controllers 

 

aux 

CAUTION: 
HOT SURFACE 

 

 

Inner surfaces of the unit 
will be very hot during and 
after operation.  Avoid 
touching the cabinet when 
loading or removing      
product. 

 
1.  Turn the power switches ON and let cabinet preheat for 30 

minutes. When the cabinet is turned on, the air heater will oper-
ate until the cabinet reaches the air temperature setpoint. Each 
display will read the actual temperature.  

The temp icon will be illuminated when the cabinet temperature 

is below the air temperature setpoint.  

 

2.  To view the temperature setpoint, press and release the SET 

key. 

3.  After preheat, load cabinet with food product. Food is held in 

various pan sizes as indicated by the spacing of the wire racks 
inside the cabinet. 

4.  When cabinet is not in use, turn power off. 

5.  Cabinet must be cleaned daily. See cleaning instructions on 

page 8. 

OPERATION 

AUX Key 

(inoperable)

 

Set Key 

Press and release 
to display temper-

ature set point 

Up Arrow Key 

Press to increase temperature set point 

(1

°

 increments) 

Down Arrow Key 

Press to decrease temperature set point 

(1

°

 increments) 

Digital Display 
Readout 

EVOR208 

Summary of Contents for EVOL208

Page 1: ...NSPECTION FREIGHT DAMAGE 4 INSTALLATION STARTUP 5 CONTROL PANEL LAYOUT 6 OPERATION 6 CONTROLLER PROGRAMMING INSTRUCTIONS 7 DAILY CLEANING PROCEDURES 8 TIPS FOR CLEANING STAINLESS STEEL 9 WIRING DIAGRA...

Page 2: ...rounded outlet 3 Use this appliance only for its intended purpose as described in the manual a This equipment is specifically designed to hold pre cooked food at temperature b This equipment is intend...

Page 3: ...ck holders NOT INCLUDED are removable for cleaning Rear and bottom duct assemblies are removable for cleaning Polycarbonate shields over top of opening with flip up feature on large warming box and sl...

Page 4: ...is page FREIGHT DAMAGE CLAIM PROCEDURE NOTE For your protection please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory Upon ac...

Page 5: ...mp electrical circuit with correct NEMA receptacle for each heater DO NOT use an extension cord Installation procedures must be performed by a qualified technician with full knowledge of all applicabl...

Page 6: ...be illuminated when the cabinet temperature is below the air temperature setpoint 2 To view the temperature setpoint press and release the SET key 3 After preheat load cabinet with food product Food i...

Page 7: ...r ON Press and hold the SET button for 3 seconds The current set point will display and F will flash Push the up or down arrow buttons to raise or lower the tempera ture set point in 1 increments Push...

Page 8: ...door by lifting the door up and out of the track Then remove metal track divider that is located be tween the doors Lastly lift the rear door up and out of the track Doors should be washed with a cle...

Page 9: ...TIPS FOR CLEANING STAINLESS STEEL Purpose Frequency Cleaning Agent Method of Application Routine Daily Soap ammonia Sponge with cloth rinse with clear water cleaning detergent and water and wipe dry...

Page 10: ...616 9996 Cord Grip 18614 0321 Blower Wheel PART NUMBER DESCRIPTION 18600 0117 Fan Safety Hi Limit 160 F w Reset Snap Disc 18616 0366 Dixell 208V 16A 208 F Set point Controller 18616 0367 Dixell 208V 1...

Page 11: ...fan is not running 1 Check the fan s cable connection correct if necessary 2 Cooling fan is defective replace if necessary Dixell Temperature con troller display is lit but the food chamber is not he...

Page 12: ...e up to 6 minutes Also the fan might run after turning the switch OFF until the tem perature falls under 120 F No heat Heater blower not running heating element not ener gized WARNING heater blower ma...

Page 13: ...n to make or assume any obligation or liability in connection with its products other than that covered in this war ranty This warranty applies only within the continental United States and Canada In...