11
2. Compare
Proceed to verify device(s).
Scroll to select "2. Compare", then press "OK" to start the verification process.
3. Copy+Compare
Sequentially automates from Function 1, Copy to Function 2, Compare.
Scroll to select "3. Copy+Compare", then press "OK" to start the automated
duplication and verification process.
Note
It is recommended to execute Compare after Copy to confirm
accuracy. Use the
function “3. Copy+Compare”.
4. Erase
There are 4 submenu modes.
Caution Please backup all important data before using this function.
Step 1: Connect device(s) for sanitizing.
Note
Source Port is disabled for erasing by default. Go to 6.7.2 to enable
source port erasing.
Step 2: Enter function "4. Erase"
Scroll to select "4. Erase”, then press "OK" to view the 4 submenus.
Note P
ress “ESC” for 5 seconds to stop all the erase jobs.
4.1 Quick Erase
This function will erase the index table from the connected device(s).
Scroll to select "4.1. Quick Erase”, then press "OK" to start the erase process.
4.2 Full Erase
This function will erase all data per NIST 800-88 Standards on the connected
device(s).
Scroll to select "4.2 Full Erase”, then press "OK" to start the erase process.