PGD4, PGS4, WPG4: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

4

Fig. 3 – Gas Heating/Electric Cooling Unit with Access Panel 

Removed

To shut off unit gas heat:

NOTE: 

If  the  unit  is being shut down  because of  a malfunction, call

your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut off, shut off the

external manual gas valve to the unit before shutting off the electrical

supply.  Do  not  use  this  unit  if  any  part  has  been  under  water.

Immediately call a qualified service technician to inspect the unit and to

replace any  part  of  the  control system  and  any gas  control which has

been under water.
Refer to 

Fig. 5

 while proceeding with the following steps.

1. Set  the  temperature  selector  on  room  thermostat  to  lowest

temperature setting and set system SWITCH to OFF.

2. Close the external manual shutoff valve.
3. Turn off the electrical power supply to the unit.
4. Remove the control access panel. (See 

Fig. 2

.)

5.   Move  the  selector  switch  on  the  internal  gas  valve  to  the  OFF

position.

6. Replace the control access panel.

To start unit electric cooling:

Refer to 

Fig. 6

 while proceeding with the following steps.

1. Set  the  temperature  selector  on  room  thermostat  to  highest

temperature setting and set system SWITCH to OFF.

2. Close the external manual shutoff valve, if not already closed.
3. Turn ON the electrical power supply to the unit.
4. Set system switch to COOL.
5. Set the temperature selector on room thermostat slightly below the

room temperature to start unit.

To shut off unit electric cooling:

Refer to 

Fig. 7

 while proceeding with the following steps.

1. Set  the  temperature  selector  on  room  thermostat  to  highest

temperature setting and set system SWITCH to OFF.

2. Close the external manual shutoff valve, if not already closed. 
3. Turn off the electrical power supply to the unit.

Operating Your Unit

The  operation  of  your  unit  is  controlled  by  the  indoor  temperature

control (thermostat). You simply adjust the thermostat and it maintains

the  indoor  temperature  at  the  level  you  select.  Most  thermostats  of

heating  and  cooling  systems  have  3  controls:  a  temperature  control

selector, a FAN control, and a SYSTEM or MODE control. Refer to your

thermostat owner’s manual for more information.
To better protect your investment and to eliminate unnecessary service

calls, familiarize yourself with the following facts:

Cooling Mode

With the SYSTEM control set to COOL, your unit will run in cooling

mode  until  the  indoor  temperature  is  lowered  to  the  level  you  have

selected. On extremely hot days, your unit will run for longer periods at

a time and have shorter “off” periods than on moderate days.

Gas Heat Mode

With the SYSTEM or MODE control of your indoor thermostat set to

HEAT,  your  unit  will  run  in  heating  mode  until  room  temperature  is

raised  to  the  level  you  have  selected.  On  cold  days  and  nights,  your

system  will  typically  run  for  longer  periods  of  time  and  have  shorter

“off” periods than on moderate days.

Maintenance and Service

This  section discusses  maintenance  that  should  be performed  on  your

system. Most maintenance should be performed by your dealer. You, as

the owner, may wish to handle some minor maintenance for your new

unit.

Routine Maintenance

All  routine  maintenance  should  be  handled  by  skilled,  experienced

personnel. Your dealer can help you establish a standard procedure.
For  your  safety,  keep  the  unit  area  clear  and  free  of  combustible

materials, gasoline, and other flammable liquids and vapors.
To assure proper functioning of the unit, flow of condenser air must not

be obstructed from reaching the unit. Clearance from the top of the unit

is 48 in. (1219 mm). Clearance of at least 36 in. (914 mm) is required on

sides except the power entry side (42 in. [1067 mm] clearance) and the

duct side (12 in. [305 mm] minimum clearance). Also, ensure that the

return-air duct connection (s) is physically sound, is sealed to the furnace

casing, and terminates outside the space containing the furnace.

WARNING

!

FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Failure  to  follow  this  warning  could  result  in  personal  injury,  death,

and/or property damage.

Do not turn off the electrical power to unit without first turning off the

gas supply.

Burners

Gas Valve

Flue Hood

Summary of Contents for WPG4

Page 1: ...er and Gas Furnace System With R 410A Refrigerant 2 5 Nominal Tons Sizes 24 60 Technician Name Phone Number Address Company Name Date Installed NOTE TO EQUIPMENT OWNER For your convience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require m...

Page 2: ...ning product is used in or around the home or business that the dwelling be equipped with a CO Alarm s The Consumer Product Safety Commission recommends the use of CO Alarm s The CO Alarm s must be installed operated and maintained according to the CO Alarm manufacturer s instructions For more information about Carbon Monoxide local laws or to purchase a CO Alarm please visit the following website...

Page 3: ...light within 5 seconds the ignition module will go into a Retry Mode after a period of approximately 22 seconds following the 5 second ignition period If the burners do not light within 15 minutes of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could r...

Page 4: ...thermostat and it maintains the indoor temperature at the level you select Most thermostats of heating and cooling systems have 3 controls a temperature control selector a FAN control and a SYSTEM or MODE control Refer to your thermostat owner s manual for more information To better protect your investment and to eliminate unnecessary service calls familiarize yourself with the following facts Coo...

Page 5: ...erves the right to change at any time specifications and designs without notice and without obligations 5 A07662 Fig 4 To Start Unit Gas Heat 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N ...

Page 6: ...at any time specifications and designs without notice and without obligations 6 A07663 Fig 5 To Shut off Unit Gas Heat A09194 Fig 6 To Start Unit Electric Cooling 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 ...

Page 7: ...zes supplied with accessory filter rack Replacing or inspecting filters in units with economizers Small Chassis See Fig 8 1 Remove return air duct cover at rear of unit using a 5 16 in nut driver 2 Remove the filter s by pulling it out and through the unit duct opening If filter is dirty replace both filters with new ones When installing the new filters note the direction of the airflow arrows on ...

Page 8: ...els After performing any maintenance or service on the unit be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pattern Combustion Area and Vent System For proper and safe operation the unit needs air for combustion and ventilation The air openings on the unit the air openings to the area in which the un...

Page 9: ...e made at this time Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation Start up and Service Instructions Warranty Certificate Your unit has a limited warranty Be sure to read the warranty carefully to determine the coverage for your unit Before you call for servi...

Page 10: ...ent as needed to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect temperature and pressure safety controls for damage X Inspect and clean if necessary burners and heat exchanger X Inspect and clean if necessary combustion air openings and vent hood X Check gas piping and shutoff valve for leaks X Check refrigerant system subcooling and or superheat sys...

Reviews: