background image

The des ign and s pecificat ions are s ubject to change w ithout prior notice for
produc t imp rove me nt. Con sult with the sales agency o r manufa cturer for details.

CS159U-BP11M

202000192485

20130513

WALL MOUNTED AIR CONDITIONER

OWNER’S MANUAL

Summary of Contents for WALL MOUNTED AIR CONDITIONER

Page 1: ...ificat ions are subject to change w ithout prior notice for produc t improve ment Con sult with the sales agency o r manufa cturer for details CS159U BP11M 202000192485 20130513 WALL MOUNTED AIR CONDITIONER OWNER S MANUAL ...

Page 2: ...the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appli...

Page 3: ...the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open or if the humidity is very high Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of any abnormalities such as smell of burning immedia...

Page 4: ...e remote controller SELF CLEAN function Optional Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation The unit will operate as following sequence FAN ONLY mode at Low fan speed Heating operation with LOW fan speed applicable to cooling heating modles only FAN ONLY operation Stop Operation Turn off This function is only available...

Page 5: ...Range Manual control button Suspension bars Manual control button AUTO COOL AUTO COOL 1 2 Manual operation Operating temperature Manual switch Manual switch Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into oper...

Page 6: ...educed and the air conditioner may stop running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C 50 F the compressor stops operation and restarts until the room t...

Page 7: ... not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached A When heating has just started B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrosting Cooling and heating models only Frost may be generated on the outdoor unit during heat cycle when outdoor temperature i...

Page 8: ...rmally Trouble OPERATION indicator or other indicators continue flashing If one of the following code appears on the display area E0 E1 E2 E3 or P0 P1 P2 P3 TROUBLESHOOTING TIPS Troubleshooting guide 8 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidity higher than 80 Adjust the horizontal louver to the maximum air outlet posit...

Reviews: