Page 11

Advanced Setup

Step #              Description                                              Range       Factory Default

1           Time of day clock set                                     24 hour            12:00 Am  
2           
3           Heat Cool                                                      Heat/Cool         Heat/Cool 
4           
5           
6           
7           

   

        

Thermoglow backlight                                    Yes/No                Yes  

Configure for Heat Pump                                Yes/No                No
Reversing Valve polarity                                   O / B                   O
Electric Heat                                                   Yes/No                 No
Deadband, Temperature swing                         1 - 6                    2

8           Cycles per hour                                            d, d1, 2 - 6              6
9           Fahrenheit or Centigrade                                  F / C                    F  
                            

Advanced Setup Table

Summary of Contents for TSTATCCPSE01

Page 1: ... WITH THE EQUIPMENT USER T S TAT C C P S E 0 1 P R O G R A M M A B L E D I G I T A L T H E R M O S T A T USER INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW THERMOSTAT Carrier Heating Cooling PROGRAMMABLE DIGITAL THERMOSTAT Meets California Title 24 Residential Heat Pump Heat Cool 7 00 68 72 Am ON FAN WAKE HEAT ...

Page 2: ...O MODE OFF PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS FRONT PANEL DISPLAY QUICK START Set the clock and go BASIC OPERATION PROGRAMMING 2 Time Periods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY 2 3 4 5 7 9 12 16 Residential Light Commerical Systems Carrier Corporation 10 01 ...

Page 3: ...72 Am ON FAN WAKE HEAT Page 2 PROGRAM ON OFF SET PROGRAM FAN PROGRAM ON OFF SET CLOCK SET PROGRAM FAN SET CLOCK MODE NEXT OUTSIDE o OUTSIDE 12 00 74 Pm WAKE HEAT 72 This Big Letter label is also available for easy identification of the thermostat buttons EasySTAT RESIDENTIAL OUTSIDE FAN SET PROGRAM PROGRAM ON OFF SET CLOCK MODE NEXT o ...

Page 4: ...4 Room Temperature Display Indicates the current room temperature Desired Set Temperature Indicates desired room temperature Page 7 Outside Indication Indicates the temperature displayed is from the optional outside sensor Fan Operation Indication Fan On indicates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or to cool Display ...

Page 5: ...g the clock Quick Start Set the Clock and Go Page 4 This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section buttons To adjust the clock use Am 12 00 SET CLOCK SET CLOCK To adjust just the Hours hold the Fan button in pressing the...

Page 6: ... in Heat or Cool modes will adjust only the heat or cool set temperature Select Desired Temperature Page 5 Basic Operation Press FAN Fan Operation Fan On indicates constant fan operation This feature is active even if the thermostat is set to Off 12 00 70 69 Am HEAT 12 00 65 OFF Am ON FAN ...

Page 7: ...ure the room has to reach before the air conditioner will turn on to cool the room Select Mode OFF indicates both heating and air conditioning systems are turned off Press Press MODE NEXT 12 00 72 74 Am COOL 12 00 72 72 Am HEAT 12 00 72 OFF Am MODE NEXT NOTE WHEN THE THERMOSTAT IS IN THE OFF MODE YOU MAY TURN THE THERMOSTAT BACK ON MY PRESSING THE MODE NEXT UP OR DOWN BUTTONS ...

Page 8: ... the Set Program button SET PROGRAM 72 74 HEAT COOL OCCUPIED 1 AUTO o o Am 6 03 68 TOTALINE The thermostat must be in the Heat mode to access these setup steps 7 00 Am WAKE 7 00 68 Am WAKE HEAT I0 00Pm SLEEP I0 00 65 Pm SLEEP HEAT Press Press Press Press MODE NEXT MODE NEXT MODE NEXT Press the Program Set or Mode Next button to leave setup and return to normal operation SET PROGRAM OR Press the Pr...

Page 9: ...e to access these setup steps 7 00 Am WAKE 7 00 74 Am WAKE COOL I0 00Pm SLEEP I0 00 78 Pm SLEEP COOL MODE NEXT MODE NEXT MODE NEXT NOTE If no buttons are pressed the thermostat will leave setup and return to normal operation after 60 seconds Press the Program Set or Mode Next button to leave setup and return to normal operation SET PROGRAM OR Press the Program On Off button to leave setup and star...

Page 10: ... On Off button to enter Setup screens PROGRAM ON OFF MODE NEXT Yes 2 L I 3 COOL No 4 HP Select Yes to have the backlight always on No to have the backlight turn off after 8 seconds after a key press Yes No Select Yes if the thermostat is controlling a heatpump No for all other types of equipment Yes No O 5 Select the reversing valve polarity for Heat Pump O or B Step 5 only appears if step 4 is Ye...

Page 11: ...lockout d d1 2 6 NO 6 EH 2 7 6 8 Cy Select thermostat operation in degrees Fahrenheit or Centigrade F C F 9 Select Electric Heat Yes if the strip heater is your First Stage of heat Step 6 only appears if step 4 is Yes for heat pump Yes No 88 Adjust the deadband from 1 6 degrees To Exit Press PROGRAM ON OFF MODE NEXT MODE NEXT MODE NEXT ...

Page 12: ...our 12 00 Am 2 3 Heat Cool Heat Cool Heat Cool 4 5 6 7 Thermoglow backlight Yes No Yes Configure for Heat Pump Yes No No Reversing Valve polarity O B O Electric Heat Yes No No Deadband Temperature swing 1 6 2 8 Cycles per hour d d1 2 6 6 9 Fahrenheit or Centigrade F C F Advanced Setup Table ...

Page 13: ... stage compressor When there is a heat demand the thermostat engages the 2nd stage of heat along with the fan Exiting Emergency Heat is the same as entering During Emergency Heat only OFF and HEAT are available the Press for Emergency Heat FAN 12 00 73 72 Am HEAT 2 STAGE OPERATION The 2nd Stage of heat or cool is turned on when 1 the 1st Stage has been on for a minimum of two minutes and 2 the tem...

Page 14: ...l appear if no sensor is connected Pressing the Outside button will then return the display to normal the display Sensor when asked to This thermostat will temperature from the Outside Sensor The Outside Sensor is available in a wired or wireless version The wired sensor can be connected to the thermostat with Unshielded See the Outside Sensor instructions for further details up to 500 of 20 ga or...

Page 15: ... minutes before you awake for air conditioning or gas heat and about 30 minutes ahead of when you wake for heat pump operation Press the MODE NEXT button again and simply use the UP and DOWN keys to select the temperature you wish the next morning Press the MODE NEXT key again and do the same adjustments as above for the SLEEP period This will be for the normal operation where you wish to have the...

Page 16: ...oled when you are not there On Saturdays and Sundays since you are there all day long you do not set the temperature back so the house is maintained at a comfortable temperature all day This thermostat is so easy to set you can easily change the SLEEP RETURN temperature Let s say you were going to the mall for two ro three hours and wish to save energy just set the SLEEP RETURN time to when you ex...

Page 17: ...NDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owner s manual including filter cleaning and or replacement a...